1-channel isolated barrier, 24 V DC supply (Power Rail), Input for NAMUR sensors or dry contacts, Input frequency 1 mHz ... 5 kHz, Current output 0/4 mA ... 20 mA, Relay contact and transistor output, Start-up override, Line fault detection (LFD), Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 40 mm, Number of channels: 1-channel, Trip relay, Start-up override, Frequency conversion, Rotation speed monitoring, Pulse divider, Safety Integrity Level (SIL): SIL 2pa
1-channel isolated barrier, Universal usage at different power supplies, Input for NAMUR sensors or dry contacts, Input frequency 1 mHz ... 5 kHz, Current output 0/4 mA ... 20 mA, Relay contact and transistor output, Start-up override, Line fault detection (LFD), Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 40 mm, Number of channels: 1-channel, Trip relay, Start-up override, Frequency conversion, Rotation speed monitoring, Pulse dividerpa
Ikke tilgjengelig: 1-channel, Control circuit EEx ia IIC, Input frequency 1 mHz ... 5 kHz, Analog output 0/4 mA ... 20 mA, Measuring range parameterisable, 2 relay outputs, 1 electronic output, isolated, Each output can be assigned individual parameters, such as a trip value (high/low alarm), serially switched output, pulse divider or error message output, Start-up override, Restart inhibit, Lead breakage (LB) and short-circuit (SC) monitoring, Debounce filterpa
Ikke tilgjengelig: 1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Input frequency 1 mHz ... 5 kHz, Current output 0/4 mA ... 20 mA, Relay and transistor output, Start-up override, Configurable by PACTware or keypad, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Housing width: 40 mm, Number of channels: 1-channel, Trip relay, Rated voltage: 20 ... 30 V DCpa
Ikke tilgjengelig: 1-channel, Control circuit EEx ia IIC, Input frequency 1 mHz ... 5 kHz, Analog output 0/4 mA ... 20 mA, Measuring range parameterisable, 2 relay outputs, 1 electronic output, isolated, Start-up override, Restart inhibit, Debounce filter, Up to SIL 2 acc. to IEC 61508, Housing width: 40 mm, Number of channels: 1-channel, Trip relay, Rated voltage: 20 ... 90 V DC / 48 ... 253 V ACpa
Ikke tilgjengelig: 1-channel isolated barrier, Universal usage at different power supplies, Dry contact or NAMUR inputs, Input frequency 1 mHz ... 5 kHz, Current output 0/4 mA ... 20 mA, Relay and transistor output, Start-up override, Configurable by PACTware or keypad, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Housing width: 40 mm, Number of channels: 1-channel, Trip relay, Rated voltage: 20 ... 90 V DC / 48 ... 253 V AC 50 ... 60 Hzpa
1-4/4Antall produkter pr. side:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.