Wsparcie Czujników Przemysłowych
Wsparcie Ochrony przed wybuchem

Czujniki indukcyjne

Choose your product

Następna stronaOstatnia strona
Produkt


Switching function: complementary, Output type: PNP, Installation: flush, Output polarity: DC, Output type: 4-wire, Construction type: VariKont ®, Series: VariKont ®, Operating voltage: 10 ... 30 V DC, Type of voltage: DC, EAC conformity: TR CU 020/2011, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: screw terminalsfa


e1, Extended temperature range, Switching function: complementary, Output type: PNP, Installation: flush, Output polarity: DC, Output type: 4-wire, Construction type: VariKont ®, Series: VariKont ®, Operating voltage: 10 ... 60 V DC, Type of voltage: DC, UL approval: cULus Listed, General Purpose, CCC approval: Certified by China Compulsory Certification (CCC), E1 Type approval: 10R-04, Ambient temperature: -40 ... 85 °C (-40 ... 185 °F)
fa


Switching function: Normally open (NO), Output type: PNP, Installation: flush, Output polarity: DC, Output type: 3-wire, Construction type: VariKont ®, Series: VariKont ®, Operating voltage: 10 ... 30 V DC, Type of voltage: DC, EAC conformity: TR CU 020/2011, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: screw terminalsfa


Switching function: Normally open/closed (NO/NC), Output type: Two-wire, Installation: flush, Output polarity: AC/DC, Output type: 2-wire, Construction type: Rectangular, Series: VariKont ®, Switching frequency: AC, 0 ... 30 Hz
DC, 0 ... 100 Hz, UL approval: cULus Listed, General Purpose
"For use in NFPA 79 Applications only"
For overcurrent protection, install a fuse with a rated current of max. 3 A and at least 300 V AC/DCfa


Switching function: Normally open/closed (NO/NC), Output type: Two-wire, Installation: flush, Output polarity: DC, Output type: 2-wire, Construction type: VariKont ®, Series: VariKont ®, Operating voltage: 5 ... 60 V DC, Type of voltage: DC, EAC conformity: TR CU 020/2011, UL approval: cULus Listed, General Purpose, CCC approval: Certified by China Compulsory Certification (CCC), Connection type: screw terminalsfa


Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Installation: flush, Output type: 2-wire, Construction type: VariKont ®, Series: VariKont ®, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0021X, Equipment protection level Gb: IECEx PTB 11.0021X, Equipment protection level Da: IECEx PTB 11.0021X, Equipment protection level Mb: IECEx PTB 11.0021X, Equipment protection level Ga: PTB 00 ATEX 2032 Xfa


Switching function: complementary, Output type: PNP, Installation: non-flush, Output polarity: DC, Output type: 4-wire, Construction type: VariKont ®, Series: VariKont ®, Operating voltage: 10 ... 30 V DC, Type of voltage: DC, EAC conformity: TR CU 020/2011, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: screw terminalsfa


Switching function: Normally open (NO), Output type: PNP, Installation: non-flush, Output polarity: DC, Output type: 3-wire, Construction type: VariKont ®, Series: VariKont ®, Operating voltage: 10 ... 30 V DC, Type of voltage: DC, EAC conformity: TR CU 020/2011, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: screw terminalsfa


e1, Extended temperature range, Switching function: Normally open (NO), Output type: PNP, Installation: non-flush, Output polarity: DC, Output type: 3-wire, Construction type: VariKont ®, Series: VariKont ®, Operating voltage: 10 ... 60 V DC, Type of voltage: DC, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: Certified by China Compulsory Certification (CCC), E1 Type approval: 10R-04fa


Switching function: Normally open/closed (NO/NC), Output type: Two-wire, Installation: non-flush, Output polarity: AC/DC, Output type: 2-wire, Construction type: Rectangular, Series: VariKont ®, Switching frequency: AC, 0 ... 30 Hz
DC, 0 ... 100 Hz, UL approval: cULus Listed, General Purpose
"For use in NFPA 79 Applications only"
For overcurrent protection, install a fuse with a rated current of max. 3 A and at least 300 V AC/DCfa
Następna stronaOstatnia strona

Filtruj wyniki

Our amplify article gives interesting insights about the development of the new, modern portfolio of inductive proximity sensors from Pepperl+Fuchs. Get the whole story here! 

 

 

Knowledge Base for Inductive Sensors

The knowledge base for inductive sensors contains extensive expertise and supports you in the highly precise and smooth operation of the sensors in your machinery and plants.

VariKont z technologią aktywnego ekranowania

Czujniki indukcyjne VariKont z technologią aktywnego ekranowania zapewniają duże odległości przełączania, niezależnie od warunków instalacji i otaczającego materiału. Skorzystaj z prostszej konstrukcji sprzętu i obniżonych kosztów!

Indukcyjne czujniki bezpieczeństwa SIL 2 PL d

Dzięki temu, że indukcyjne czujniki bezpieczeństwa SIL 2/PL d nie mają martwej strefy, przesyłanie danych może odbywać się bez minimalnej odległości między czujnikiem a obiektem docelowym. Odkryj ofertę zoptymalizowaną pod kątem wymagających środowisk.