AC Power Supply PSU1200-J2-AC-N0

PSU1200-J2-AC-N0
  • Certified for ATEX and IECEx Zone 2/22
  • UL listed for USA and Canada
  • Galvanic isolation between input and output
  • Provides an output power up to 80 W at 24 V DC
  • Fully IP66 rated

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Загрузить подробное описание::


Краткое описание: технические характеристики  PSU1200-J2-AC-N0

Описание оборудования
AC Power Supply
Supply
Input voltage115/230 V AC , 50/60 Hz
Input currentmax. 1.5/0.7 A
Output
Output rated operating currentmax. 3.4 A
Voltage24 V DC (SELV)
Power80 W with derating
Power dissipation15 W at 80 W output power
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations) ; EN 61000-6-4:2007+A1:2011
RoHS
Directive 2011/65/EU (RoHS)EN 50581:2012-09
Ambient conditions
Operating temperature-20 ... 65 °C (-4 ... 149 °F) with derating
Storage temperature-20 ... 65 °C (-4 ... 149 °F)
Relative humidity93% at 40°C, non-condensating, according to EN 60068-2-78
Shock resistance18 shocks 15 g , 11 ms all axis, IEC 60068-2-27
Mechanical specifications
Core cross-sectionmax. 2.5 mm2 (14 AWG)
Degree of protectionIP66
Material
Housinganodized aluminum
Massapprox. 3.2 kg
Dimensions245 mm x 122 mm x 58 mm
Data for application in connection with hazardous areas
EU-Type Examination CertificateBVS 16 ATEX E 097 X
MarkingEx-Hexagon II 3G Ex ec q IIC T4 Gc
Ex-Hexagon II 3D Ex tc IIIC T85°C Dc
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013, EN 60079-5:2015, EN 60079-7:2015, EN 60079-31:2014
International approvals
UL approvalE492874
Approved forClass I, Division 2, Groups A, B, C, D T4; Zone 2, Group IIC T4
Class II, Division 2, Groups F, G T4; Zone 22, Group IIIB T85
Class III; Zone 22, Group IIIA T85
IECEx approvalIECEx BVS 16.0063X
Approved forEx ec q IIC T4 Gc
Ex tc IIIC T85°C Dc
StandardsIEC 60079-0:2011 , IEC 60079-5:2015 , IEC 60079-7:2015 , IEC 60079-31:2013

Classifications

SystemClasscode
ECLASS 11.019209290
ECLASS 10.0.119209290
ECLASS 9.019209290
ECLASS 8.019209290
ECLASS 5.127242392
ETIM 7.0EC002542
ETIM 6.0EC002542
ETIM 5.0EC002542
UNSPSC 12.139121004

Documents: PSU1200-J2-AC-N0

ManualsЯзыкТип файлаРазмер файла
ManualENGPDF1521 KB
HandbuchGERPDF2357 KB
Instruction manuals
ИнструкцииBULPDF145 KB
Návod k poużitíCZEPDF139 KB
Instruction manualENGPDF147 KB
KasutusjuhendESTPDF133 KB
KäyttöohjeFINPDF132 KB
Manuel d'instructionsFRAPDF141 KB
BetriebsanleitungGERPDF150 KB
Οδηγίες χρήσηςGREPDF2 KB
HandleidingHOLPDF139 KB
Instruction manual / BetriebsanleitungHRVPDF137 KB
Lietošanas pamācībaLAVPDF137 KB
Instrukciju vadovasLITPDF139 KB
Instrukcja obsługiPOLPDF140 KB
Manual de instruçõesPORPDF140 KB
Manual de utilizareRONPDF139 KB
Návod na poużitieSLKPDF139 KB
Navodila za uporaboSLVPDF137 KB
Manual de instruccionesSPAPDF141 KB
ManualSWEPDF136 KB

Approvals+Certificates: PSU1200-J2-AC-N0

Statements of complianceСертификат №Тип файлаРазмер файла
EU-Declaration of conformity / EU-KonformitätserklärungDOC-3338APDF151 KB
Certificates
ATEX CertificateBVS 16 ATEX E 097 XPDF7555 KB
China SITIIAS CCC Ex Certificate2020322303003369PDF950 KB
IECEx Certificate of ConformityIECEx BVS 16.0063XLINK---
UL Hazardous LocationE492874 (NRAG, NRAG7)PDF405 KB

Сопутствующие продукты: PSU1200-J2-AC-N0

Accessory of
VisuNet GXP Remote Monitor Zone 2/22 (2016 Generation), 21.5" (54.61 cm) display, 16:9 aspect ratio widescreen formatting to match engineering stations, Thin Client solution (with VisuNet RM Shell firmware), Lightweight design, Full HD Resolution, Completely modular system for easy field maintainability, Flush or bezel mounting options, IP66 rating for each individual component and entire system with housing, Certified for ATEX and IECEx Zone 2/22, UL listed for USA and Canadapa
VisuNet GXP Remote Monitor Zone 2/22 (2016 Generation), 19 in (48 cm) display, Thin Client solution (with VisuNet RM Shell firmware), Lightweight design, Completely modular system for easy field maintainability, Flush or bezel mounting options, IP66 rating for each individual component and entire system with housing, Certified for ATEX and IECEx Zone 2/22, UL listed for USA and Canadapa
VisuNet GXP PC Zone 2/22 (2020 Generation, Intel (R) Atom Apollo Lake Processor), 21.5" (54.61 cm) display, 16:9 aspect ratio widescreen formatting to match engineering stations, PC solution with pre-installed Windows® operating system, Lightweight design, Full HD Resolution, Completely modular system for easy field maintainability, Flush or bezel mounting options, IP66 rating for each individual component and entire system with housing, Certified for ATEX and IECEx Zone 2/22pa
Display Unit, 10 point multi-touch sensor option allows design of modern user interfaces, Highly resistant to cleaning agents with stainless steel bezel and seamless glass design, Design optimized for easy cleanability, Low-power consumption and heat dissipation due to LED backlight technologypa
VisuNet GXP Remote Monitor Zone 2/22 (2020 Generation, Intel (R) Atom Apollo Lake Processor), 19 in (48 cm) display, Thin Client solution (with VisuNet RM Shell firmware), Lightweight design, Completely modular system for easy field maintainability, Flush or bezel mounting options, IP66 rating for each individual component and entire system with housing, Certified for ATEX and IECEx Zone 2/22, UL listed for USA and Canadapa
VisuNet GXP PC Zone 2/22 (2016 Generation), 21.5" (54.61 cm) display, 16:9 aspect ratio widescreen formatting to match engineering stations, PC solution with pre-installed Windows® operating system, Lightweight design, Full HD Resolution, Completely modular system for easy field maintainability, Flush or bezel mounting options, IP66 rating for each individual component and entire system with housing, Certified for ATEX and IECEx Zone 2/22, UL listed for USA and Canadapa
VisuNet GXP Remote Monitor Zone 2/22 (2020 Generation, Intel (R) Atom Apollo Lake Processor), 21.5" (54.61 cm) display, 16:9 aspect ratio widescreen formatting to match engineering stations, Thin Client solution (with VisuNet RM Shell firmware), Lightweight design, Full HD Resolution, Completely modular system for easy field maintainability, Flush or bezel mounting options, IP66 rating for each individual component and entire system with housing, Certified for ATEX and IECEx Zone 2/22pa
VisuNet GXP PC Zone 2/22 (2020 Generation, Intel (R) Atom Apollo Lake Processor), 19 in (48 cm) display, PC solution with pre-installed Windows® operating system, Lightweight design, Completely modular system for easy field maintainability, Flush or bezel mounting options, IP66 rating for each individual component and entire system with housing, Certified for ATEX and IECEx Zone 2/22, UL listed for USA and Canadapa
VisuNet GXP PC Zone 2/22 (2016 Generation), 19 in (48 cm) display, PC solution with pre-installed Windows® operating system, Lightweight design, Completely modular system for easy field maintainability, Flush or bezel mounting options, IP66 rating for each individual component and entire system with housing, Certified for ATEX and IECEx Zone 2/22, UL listed for USA and Canadapa
Display Unit, 10 point multi-touch sensor option allows design of modern user interfaces, Highly robust against cleaning agents and solvents due to seamless glass design, Optimized design for an easy cleanability, Low-power consumption and heat dissipation due to LED backlight technologypa
Accessories
Bracket for VisuNet PSUs, Mounting bracket, Simple and fast mounting, Same hole pattern as OB11-J-AC1-N-N-N-Npa

Function: PSU1200-J2-AC-N0

The device is an apparatus certified for use in hazardous areas rated according to ATEX directive and IECEx Zones 2 and 22.

The device is an AC-DC power supply and supplies explosion-protected equipment in the hazardous area. The device provides an output voltage of 24 V DC based on 110 V AC/230 V AC input voltage.

The output power has a derating from 50 °C to 65 °C (80 W to 50 W).

The device is optimized for use with the following devices:

  • Display Unit DPU1200-J2-*

  • Thin Client Unit TCU1200-J2-*

  • PC Unit PCU1200-J2-*