Serviceline Industrial Sensors
Serviceline Explosion Protection

Not available for purchase

This product has been replaced.Go to replacement product NBB15-U4K-N0
Not available for purchase
Not available for purchase

Inductive sensor NCB15+U4+N0

NCB15+U4+N0
  • Comfort series
  • 15 mm flush


NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below:

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Datasheet excerpt: Technical data of  NCB15+U4+N0

General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance15 mm
Installationflush
Assured operating distance0 ... 12.15 mm
Actual operating distance13.5 ... 16.5 mm typ.
Reduction factor rAl 0.28
Reduction factor rCu 0.25
Reduction factor r304 0.75
Output type2-wire
Nominal ratings
Nominal voltage8.2 V (Ri approx. 1 kΩ)
Switching frequency0 ... 400 Hz
Hysteresis1 ... 15 typ. 5 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
Current consumption
Measuring plate not detectedmin. 3 mA
Measuring plate detected≤ 1 mA
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd5128 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
Electromagnetic compatibilityNE 21:2007
StandardsEN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
IECEx approval
Equipment protection level GaIECEx PTB 11.0021X
Equipment protection level GbIECEx PTB 11.0021X
Equipment protection level DaIECEx PTB 11.0021X
ATEX approval
Equipment protection level GaPTB 00 ATEX 2032 X
Equipment protection level GbPTB 00 ATEX 2032 X
Equipment protection level DaPTB 00 ATEX 2032 X
FM approval
Control drawing116-0165
UL approval
Ordinary LocationE87056
Hazardous LocationE501628
Control drawing116-0451
CSA approvalcCSAus Listed, General Purpose
CCC approval
Hazardous Location2020322315002302
NEPSI approval
NEPSI certificateGYJ16.1394X
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection typescrew terminals
Information for connectionA maximum of two conductors with the same core cross section may be mounted on one terminal connection!
tightening torque 1.2 Nm + 10 %
Core cross sectionup to 2.5 mm2
Minimum core cross-sectionwithout wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2
Maximum core cross-sectionwithout wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2
Housing materialPBT/metal
Sensing facePBT
Degree of protectionIP68
Dimensions
Height40 mm
Width40 mm
Length118 mm
NoteTightening torque: 1.8 Nm (housing)
General information
Use in the hazardous areasee instruction manuals

Classifications

SystemClasscode
ECLASS 13.027274001
ECLASS 12.027274001
ECLASS 11.027270101
ECLASS 10.0.127270101
ECLASS 9.027270101
ECLASS 8.027270101
ECLASS 5.127270101
ETIM 9.0EC002714
ETIM 8.0EC002714
ETIM 7.0EC002714
ETIM 6.0EC002714
ETIM 5.0EC002714
UNSPSC 12.139121550

Details: NCB15+U4+N0

Datasheet: NCB15+U4+N0

DatasheetFile TypeFile Size
数据表 NCB15+U4+N0PDF310 KB
Datasheet NCB15+U4+N0PDF232 KB
Datasheet NCB15+U4+N0PDF193 KB
Fiche de données NCB15+U4+N0PDF230 KB
Datenblatt NCB15+U4+N0PDF195 KB
Scheda tecnica NCB15+U4+N0PDF230 KB
Datasheet NCB15+U4+N0PDF235 KB
Folha de dados NCB15+U4+N0PDF231 KB
Hoja de datos NCB15+U4+N0PDF230 KB
Datasheet NCB15+U4+N0PDF241 KB

Documents: NCB15+U4+N0

Instruction manualsFile TypeFile Size
ИнструкцииPDF189 KB
Návod k poużitíPDF182 KB
Instruktions manualPDF180 KB
Instruction manualPDF182 KB
KasutusjuhendPDF176 KB
KäyttöohjePDF175 KB
Manuel d'instructionsPDF185 KB
BetriebsanleitungPDF183 KB
Οδηγίες χρήσηςPDF192 KB
HandleidingPDF181 KB
Instruction manual / BetriebsanleitungPDF180 KB
Használati útmutatóPDF185 KB
Manuale di istruzioniPDF183 KB
Lietošanas pamācībaPDF181 KB
Instrukciju vadovasPDF182 KB
Instrukcja obsługiPDF244 KB
Manual de instruçõesPDF185 KB
Manual de utilizarePDF185 KB
Návod na poużitiePDF183 KB
Navodila za uporaboPDF180 KB
Manual de instruccionesPDF185 KB
ManualPDF180 KB
Technical information
Installation conditionsPDF210 KB
EinbaubedingungenPDF210 KB

CAD+CAE: NCB15+U4+N0

CADFile TypeFile Size
CAD 3-D / CAD 3-DSTP181 KB
EPLAN
CAE EPLAN Data Portal / CAE EPLAN Data PortalLINK---
EPLAN macro EDZ / EPLAN Makro EDZEDZ53 KB

Associated Products: NCB15+U4+N0

Accessories

Mounting aid for VariKont and +U1+ fa
Modular mounting bracket fa

Our amplify article gives interesting insights about the development of the new, modern portfolio of inductive proximity sensors from Pepperl+Fuchs. Get the whole story here! 

 

 

Knowledge Base for Inductive Sensors

The knowledge base for inductive sensors contains extensive expertise and supports you in the highly precise and smooth operation of the sensors in your machinery and plants.

VariKont with Active Shielding Technology

The VariKont inductive sensors with Active Shielding Technology ensure high switching distances, no matter the installation situation and the surrounding material. Benefit from easier equipment design and reduced costs!

Inductive Safety Sensors SIL 2 PL d

As the SIL 2/PL d inductive safety sensors have no dead band, data transfer can occur with no minimum distance between sensor and target. Discover the optimized portfolio for demanding environments.