Serviceline Industrial Sensors
Serviceline Explosion Protection

PS Industrial Power Supplies

Choose your product

Next PageLast Page
Product

100 V AC to 240 V AC wide-range input, Output 24 V DC, 10 A, 240 W, 1-phase, Housing width 39 mm, Efficiency up to 95.2 %, Minimal inrush current surge, DC OK relay contact, Suitable for Zone 2/Div. 2 mounting, Device type: device for DIN rail mounting, Rated voltage: 24 V DC, Current: 12 ... 10.3 A at ambient temperature < 45 °C (113 °F)
10 ... 8.6 A at ambient temperature 60 °C (140 °F)
7.5 ... 6.5 A at ambient temperature 70 °C (158 °F)
linear power derating see derating curvespa

100 V AC to 240 V AC wide-range input, Output 24 V DC, 10 A, 240 W, 1-phase, Housing width 39 mm, Built-in decoupling mosfet for 1+1 and N+1 redundancy, Efficiency up to 94.7 %, Minimal inrush current surge, DC OK relay contact, Current sharing for parallel use, Suitable for Zone 2/Div. 2 mounting, Device type: device for DIN rail mounting, Rated voltage: 24 V DCpa

100 V AC to 240 V AC wide-range input, Output 24 V DC, 20 A, 480 W, 1-phase, Housing width 48 mm, Efficiency up to 95.6 %, Minimal inrush current surge, DC OK relay contact, Current sharing for parallel use, Suitable for Zone 2/Div. 2 mounting, Device type: device for DIN rail mounting, Rated voltage: 24 V DCpa

100 V AC to 240 V AC wide-range input, Output 24 V DC, 20 A, 480 W, 1-phase, Housing width 48 mm, Built-in decoupling mosfet for 1+1 and N+1 redundancy, Efficiency up to 95.2 %, Minimal inrush current surge, DC OK relay contact, Current sharing for parallel use, Suitable for Zone 2/Div. 2 mounting, Device type: device for DIN rail mounting, Rated voltage: 24 V DCpa

100 V AC to 240 V AC wide-range input, Output 24 V DC, 5 A, 120 W, 1-phase, Housing width 32 mm, Efficiency up to 94.3 %, Minimal inrush current surge, DC OK relay contact, Suitable for Zone 2/Div. 2 mounting, Device type: device for DIN rail mounting, Rated voltage: 24 V DC, Current: 6 ... 5.1 A at ambient temperature < 45 °C (113 °F)
5 ... 4.3 A at ambient temperature 60 °C (140 °F)
3.8 ... 3.2 A at ambient temperature 70 °C (158 °F)
linear power derating see characteristic curvepa

24 V DC to 28 V DC input, 2 inputs with 1 output, Output 24 V DC, 20 A, Housing width 32 mm, Built-in decoupling mosfets for 1+1 and N+1 redundancy, Automatic load sharing, Reverse input polarity protection, Easy wiring: distribution terminal for negative pole included, Redundancy status indicator, Suitable for Zone 2/Div. 2 mounting, Device type: device for DIN rail mounting, Voltage: 24 ... 28 V DCpa

12 V DC to 28 V DC input, 2 inputs with 1 output, Output 24 V DC, 40 A, Housing width 36 mm, Built-in decoupling mosfets for 1+1 and N+1 redundancy, Only 72 mV voltage drop at 20 A output current, Only 1.7 W loss at 2 x 10 A and 5.9 W at 2 x 20 A input current, Reverse input polarity protection, Suitable for Zone 2/Div. 2 mounting, Device type: device for DIN rail mounting, Voltage: 12 ... 28 V DCpa

PS3500 Diagnostic Module for use with PS3500 power supplies.pa

6 position backplane for use with PS3500 Power Supplies.pa

100 V AC to 240 V AC wide-range input, Output 48 V DC, 5.4 A, 260 W, 1-phase, Housing width 39 mm, Efficiency up to 95.5 %, Minimal inrush current surge, DC OK relay contact, Suitable for Zone 2/Div. 2 mounting, Device type: device for DIN rail mounting, Rated voltage: 48 V DC, Current: 6 ... 5.2 A at ambient temperature < 45 °C (113 °F)
5.4 ... 4.6 A at ambient temperature 60 °C (140 °F)
4 ... 3.4 A at ambient temperature 70 °C (158 °F)
linear power derating see characteristic curvepa
Next PageLast Page

Narrow down search result list