Serviceline Industrial Sensors
Serviceline Explosion Protection

Optical reader - safePXV/PUS PXV80AQS-F200-R4-V19

PXV80AQS-F200-R4-V19
  • RS-485 interface
  • Noncontact positioning on Data Matrix tape PXV...-AA...
  • Mechanically rugged: no wearing parts, long operating life, maintenance-free
  • High resolution and precise positioning, especially for facilities with curves and switch points as well as inclines and declines.
  • Traverse distance up to 100 km
  • Output of code quality
  • Pollution detection

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  PXV80AQS-F200-R4-V19

Product Description
Read head for use with the safe evaluation unit PUS-* (series)
General specifications
Passage speed≤ 10 m/s
Measuring rangemax. 100000 m
Light typeIntegrated LED lightning (red/blue)
Latency20 ms ±0.6
Close time70 µs (During this time a change of the color specification is delayed)
Read distance80 mm
Depth of focus± 25 mm
Field of view100 mm x 65 mm
Ambient light limit30000 Lux
Resolution
Non safety-related X± 1 mm
Safety-related X± 1 cm
Accuracy
Non safety-related X± 0.2 mm
Safety-related XSee the original instructions
Measuring frequency100 Hz
Nominal ratings
Camera
TypeCMOS , Global shutter
Processor
Clock pulse frequency600 MHz
Speed of computation4800 MIPS
Digital resolution32 Bit
Time delay before availability6 s
Functional safety related parameters
MTTFd96 a
Mission Time (TM)10 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
LED indication7 LEDs (communication, alignment aid, status information)
Electrical specifications
Operating voltage14.5 ... 30 V DC , PELV (with unloaded switching outputs)
No-load supply currentmax. 200 mA
Power consumption3 W
max: 3.7 W
Interface
Interface typeRS 485 interface
Data output codebinary code
Transfer rate115200 Bit/s
Termination120 Ω, switchable
Query cycle time≥ 7 ms
Input
Input typeInput 1: enable blue (active high)
Input 2: enable red (active high)
Input 3: color change (low:red, high: blue)
LevelLow: 0 V… 8 V
High: 10 V … +Vb
Input resistance32 kΩ
Input capacity500 pF
Output
Output type1 switch output PNP , PNP , programmable , short-circuit protected
Switching voltageOperating voltage
Switching current150 mA each output
Standard conformity
Emitted interferenceEN 61000-6-4:2007+A1:2011    
Noise immunityEN 61000-6-2:2005    
Shock resistanceEN 60068-2-27:2009
Vibration resistanceEN 60068-2-6:2008
Approvals and certificates
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Operating temperature0 ... 60 °C (32 ... 140 °F) ,   -20 ... 60 °C (-4 ... 140 °F) (noncondensing; prevent icing on the lens!)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity90 % , noncondensing
Mechanical specifications
Connection type8-pin, M12 x 1 connector
Degree of protectionIP67
Material
HousingPC/ABS
Massapprox. 160 g
Dimensions
Height70 mm
Width70 mm
Depth50 mm
General information
Note0° orientation to the DataMatrix code tape

Classifications

SystemClasscode
ECLASS 13.027270918
ECLASS 12.027270918
ECLASS 11.027270701
ECLASS 10.0.127270701
ECLASS 9.027270701
ECLASS 8.027270701
ECLASS 5.127270701
ETIM 9.0EC004672
ETIM 8.0EC002999
ETIM 7.0EC002999
ETIM 6.0EC002999
ETIM 5.0EC001852
UNSPSC 12.143211711

Details: PXV80AQS-F200-R4-V19

Product Documentation: PXV80AQS-F200-R4-V19

Language Selection:
ManualsLanguageFile TypeFile Size
ManualENGPDF7037 KB

Design / Simulation: PXV80AQS-F200-R4-V19

Language Selection:
CADLanguageFile TypeFile Size
CAD 3-D / CAD 3-DALLSTP2086 KB

Approvals: PXV80AQS-F200-R4-V19

Language Selection:
Declaration of ConformityCert No.LanguageFile TypeFile Size
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-3820DALLPDF134 KB

Associated Products: PXV80AQS-F200-R4-V19

Matching System Components
Data Matrix code tape, High chemical resistance, Low weight, Self-adhesive mounting, High temperature resistance, High mechanical stabilityfa
DataMatrix metal code bars for positioning safePXV and safePGV read heads, High temperature resistance, High mechanical stability, Easily exchangeable, Chemically highly resistant, 2-colored Data Matrix codesfa
Accessories

Female connector M12 straight A-coded 8-pin, for cable diameter 5 - 8 mm, shielded, field-attachablefa
Female connector, M12, 8-pin, shielded, field attachablefa
Grounding clip for PCV system, Stainless steel version, Low weight, M12 plug connection, High mechanical stabilityfa
Mounting bracket for PCV* read headfa
Alignment guide for PCV80-* read headfa
Marker head for 25 mm code tape, For 25 mm code tapes, Can be used for PCV80..., PCV100..., and PCV130... readers, Includes 2 x edding® 3000 permanent markersfa
Cordset M12 socket straight to M12 plug straight A-coded, 8-pin, PUR cable black, shielded, UL-approved, drag chain suitablefa
Functional Safety Hub from Pepperl+Fuchs

Several hundred products with a SIL/PL assessment, free tools, and brochures in one place: the "Functional Safety Hub" is your starting point when you have to implement safety functions.

Absolute positioning systems safePXV and safePGV

For the first time, the new absolute positioning systems safePXV and safePGV realize safety level SIL 3/PL e with a single sensor …