S* Instrument Housings Ex d IIC

Key Benefits at a Glance

  • Various enclosure materials available
  • Ex d, Ex e and Ex tD certified
  • Safe protection for various instruments
  • Installation in Zone 1, Zone 2, Zone 21 and Zone 22
  • Degree of protection IP66 / IP67
  • Thermo-resistant tempered glass window

Show more

Note

All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

EN
  • EN

Technical data of S*

Enclosure coverthreaded round cover
Cover fixingflamepath thread
Degree of protectionIP66 (IP66/IP67 with O-ring)
Cable entrysee data table
Defined entry areasee data table
Material
Enclosurealuminum alloy
Glassthermo-resistant tempered glass
Finishpainted grey
Masssee data table
GroundingM5 external grounding points
Ambient temperature-50 ... 60 °C (-58 ... 140 °F) (-20 °C (-4 °F)/+40 °C (104 °F))
EU-type examination certificateINERIS 01 ATEX 0023
MarkingEx-Hexagon II 2 GD Ex d IIC, Ex tD A21
[exsign] II 2 GD Ex e II, Ex tD A21
Degree of protectionEN 60529
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Optional accessoriessee data table