Ej tillgänglig för köp: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Ej tillgänglig för köp: 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometerpa
Ej tillgänglig för köp: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Ej tillgänglig för köp: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Ej tillgänglig för köp: 1-channel signal conditioner, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters, current and voltage sources, Current and voltage output, Housing width: 20 mm, Number of channels: 1-channel, Rated voltage: 19 ... 90 V DC / 48 ... 253 V AC, Field device: 2-wire transmitter, Field device [2]: 3-wire transmitter, Field device [3]: current source, Signal: 0/4 ... 20 mA, Signal [2]: 0/2 ... 10 V, Signal: 1 x 0/4 ... 20 mA (current source), Signal [2]: 1 x 0/2 ... 10 Vpa
Ej tillgänglig för köp: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Ej tillgänglig för köp: 2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact), Reversible mode of operationpa
Ej tillgänglig för köp: Diffuse sensor with measurement core technology, large housing design, background suppression and 3 more adjustable operating modes, IO-Link interface, 800 mm adjustable detection range, red light, 2 push-pull outputs, fixed cable, Cost-optimized series for standard tasks, Sensing-by-ranging functionality, IO-Link interface for service and process data, PowerBeam transmitter LED, Large adjustment range can be precisely definedfa
Överblick: The HART-Multiplexer-System from Pepperl+Fuchs enables communication between a PC and "smart" field devices supporting the HART protocol Existing plants can be modernized and extended easily by using the advantages of HART communication ... Överblick: The HART-Multiplexer-System from Pepperl+Fuchs enables communication between a PC and "smart" field devices supporting the HART protocol. Existing plants can be modernized and extended easi ...
The Tab-Ex 04 Pro from Pepperl+Fuchs is the world's first 5G Android™ tablet with a 10-inch display Learn more about the next-generation mobility device for use in Zone 2/22 and Division 2 hazardous ... capacity can be expanded from 512 GB to 1 TB using an external microSD card. The device has been enhanced with 5G and Wi-Fi® 6E connectivity , providing the latest in data speeds and functionality. The US market version also offers connectivity for LTE Band ...
The WILSEN platform offers three LoRa-based, battery-powered sensor solutions for a wide range of M+O applications ... (v3 and v4) via the Network API Key. Alternatively, the devices can be parameterized directly on site via Bluetooth® LE using a mobile device app for Android or iOS . As another helpful component for optimizing battery performance, Pepperl+Fuchs also ...
Get an overview of Pepperl+Fuchs' broad portfolio of HMI systems for process industries ... in hazardous areas. VisuNet RM Shell 6 VisuNet RM Shell 6 is the latest generation firmware for VisuNet Remote Monitors and Box Thin Clients from Pepperl+Fuchs. Using standard Ethernet technology , the software communicates with the process control system or ...
Gå till ”funktionssäkerhetsnavet” hos Pepperl+Fuchs, där du kan se säkerhetsbedömda enheter för tillämpningar inom fabriksautomation och dessutom få åtkomst till praktiska verktyg och broschyrer ... . Det måste vara möjligt att använda dessa enheter i trånga utrymmen och de måste vara motståndskraftiga mot inverkan från miljön, t.ex. damm, smuts och fukt. USI®-safety är det enda säkra systemet med ultraljudssensorer i enlighet med EN ISO 13849 kategori 3 PL d . Det möjliggör ...
48V motor control modules have several advantages, as they enable the construction of flexible and cost-efficient conveyor lines Learn more about Pepperl+Fuchs' G20 48V modules for complex conveyor t ... technology in the future based on a modular system. Highlights of the G20 48 V Motor Control Module G20 48 V modules for controlling DC motorized rollers with twice the power using the same power consumption Increased cost efficiency: Savings on power supply ...
Pepperl+Fuchs provides smart solutions for industrial communcation-based IIoT applications in hazardous areas ... and needs to be replaced soon. Current device data on the status is output via the HART communication protocol . In the event of a planned plant shutdown , the valve can be replaced by a technician using work order management. The technician can ...
Whistleblower and complaint management: For Pepperl+Fuchs, acting in accordance with regulations, laws and our internal guidelines and codes of conduct is a matter of course ... „report number“ for each method of submitting information. Speak Up is available around the clock in a broad range of languages worldwide, so you can access your report at any time and view its current status using your report number. You can only view ...
Find out more about the setup options for industrial radar sensors from Pepperl+Fuchs ... evaluated by recording up to ten reflections in one measuring cycle (distance values with reflection amplitude) using the "Reflections Array List" . The alignment of the sensor to the reference target is crucial here in order to obtain a stable signal via ...
Find out more about radar reflectivity and radar cross-section (RCS) ... detection ranges are given by objects with a lower RCS or by using smaller corner reflectors (here 0.5 m² as an example). The following table shows typical radar cross-section values and the resulting detection range within which a type MWC25M radar sensor ...
11-20/193Items Per Page:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.