Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Tam veri sayfasını PDF olarak indirin:
Ürün Açıklaması | ||
---|---|---|
Wireless ultrasonic sensor with LoRaWAN interface |
General specifications | ||
---|---|---|
Radio network | LoRaWAN | |
Measurement frequency | 5 min ... 24 h | |
Main sensor | ||
Detection type | ultrasonic | |
Sensing range | 150 ... 2500 mm | |
Dead band | 0 ... 150 mm | |
Resolution | 10 mm | |
Accuracy | ± 3 % of full-scale value over the entire temperature range | |
Integrated sensor technology | ||
GPS sensor | for geo-positioning | |
Temperature sensor | ||
Resolution | 0.5 °C | |
Accuracy | ± 2 °C | |
Electrical specifications | ||
Power supply | high capacity lithium battery 3.6 V , 13000 mAh battery lifetime approx. 5 years under Central European environmental conditions (- 25 °C .... + 70 °C) 3 measurements/day, 1 geolocation/day with 1 wireless transmission/day with sufficient network coverage. |
|
Interface 1 | ||
Interface type | Bluetooth 5.0 LE | |
Transmitter radiated power | + 8 dBm | |
Frequency range | 2402 ... 2480 MHz | |
Interface 2 | ||
Interface type | LoRaWAN | |
Specification | LoRaWAN interface specification V1.0.3 | |
Device type | LoRaWAN class A device | |
Transmitter frequency | 868 MHz | |
Transmitter radiated power | + 8 dBm | |
Frequency range | 863 ... 870 MHz (Europe) |
|
Transfer frequency | 5 min ... 24 h | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 301 489-1 V2.2.0:2017 EN 301 489-3 V2.1.1:2019 EN 301 489-17 V3.2.0:2017 EN 301 489-19 V2.1.0:2017 |
|
Radio and telecommunication terminal equipment | ||
Directive 2014/53/EU | EN 300 220-2 V3.1.1:2017 EN 300 328 V2.1.1:2016 EN 303 413 V1.1.1:2017 |
|
RoHS | ||
Directive 2011/65/EU (RoHS) | EN 50581:2012-09 | |
Conformity | ||
Mech. capacity | EN 60947-5-2:2007 + A1:2012 IEC 60947-5-2:2007 + A1:2012 |
|
Shock resistance | EN 60947-5-2:2007 + A1:2012 IEC 60947-5-2:2007 + A1:2012 |
|
Vibration resistance | EN 60947-5-2:2007 + A1:2012 IEC 60947-5-2:2007 + A1:2012 |
|
Climatic conditions | EN 60947-5-2:2007 + A1:2012 IEC 60947-5-2:2007 + A1:2012 |
|
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Degree of protection | IP66 / IP67 | |
Material | ||
Housing | PC (UL94-V0) | |
Transducer | PTFE coated housing: PBT |
|
Mass | 600 g | |
Factory settings | ||
Beam width | medium (profile B) | |
Transfer frequency | 24 h | |
Measurement frequency | 8 h |
System | Classcode |
---|---|
ECLASS 11.0 | 27272803 |
ECLASS 10.0.1 | 27272803 |
ECLASS 9.0 | 27272803 |
ECLASS 8.0 | 27272803 |
ECLASS 5.1 | 27272803 |
ETIM 8.0 | EC001849 |
ETIM 7.0 | EC001849 |
ETIM 6.0 | EC001849 |
ETIM 5.0 | EC001849 |
UNSPSC 12.1 | 41111960 |
Manuals | Dil | Dosya Tipi | Dosya Boyutu |
---|---|---|---|
Manual WILSEN.sonic.level WS-UCC*-F406-B15-B41* | ENG | 2357 KB | |
Handbuch WILSEN.sonic.level WS-UCC*-F406-B15-B41* | GER | 3082 KB | |
Instruction leaflets | |||
Brief Commissioning Instructions / Kurz-Inbetriebnahmeanleitung | ALL | 601 KB | |
Technical information | |||
Integration into a LoRa Network for WS-UCC*-F406-B15-B41* | ENG | 1181 KB | |
Payload Description for WS-UCC*-F406-B15-B41* | ENG | 220 KB | |
Integration in ein LoRa-Netzwerk für WS-UCC*-F406-B15-B41* | GER | 1180 KB | |
Payload-Beschreibung für WS-UCC*-F406-B15-B41* | GER | 228 KB |
CAD | Dosya Tipi | Dosya Boyutu | |
---|---|---|---|
3-D model / 3-D-Modell | STP | 10365 KB |
Statements of compliance | Sertifika No. | Dosya Tipi | Dosya Boyutu |
---|---|---|---|
EU-Declaration of conformity / EU-Konformitätserklärung | DOC-4706 | 36 KB |
Software Tools | Sürüm Bilgileri | Dosya Tipi | Dosya Boyutu |
---|---|---|---|
Payload-Decoder/Javascript Code for Decoding the Sensor Payload / Payload-Decoder/Javascript Code für die Decodierung der Sensor-Payload | 05/2020 | ZIP | 1 KB |
The wireless ultrasonic sensor can be used for remote monitoring of fill level.
The fill level, but also other parameters such as geo data and sensor status data, are measured or recorded in configurable time intervals and transmitted to a counterpart in the LoRa network from where they are available for pure display or further processing.
The sensor is parameterised via a Bluetooth interface using a mobile device (smartphone or tablet) and the WILSENcontrol app belonging to the sensor.