Fabrika Otomasyonu
Proses Otomasyonu

Kontrol Üniteleri (Ex e)

Ürününüzü seçin

Sonraki SayfaSon Sayfa
Product

Glass fiber reinforced polyester (GRP) enclosure, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Ex de, Ex ib and Ex tb certified, Up to 4 operators per enclosure, Customizable configuration of operators, cable entry quantities and cable gland types as per specification, Wide range of labels and accessories available, 2 enclosure size options, Degree of protection IP66, Function: see data table, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F)
-50 °C (-58 °F) on requestpa

Polyamide (PA) enclosure, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Ex db eb, Ex ib and Ex tb certified, Up to 5 operators per enclosure, Customizable configuration of operators, contact modules and cable entries as per specification, Wide range of labels and accessories available, 5 enclosure size options, Degree of protection IP66, Installation in portrait, landscape on request, Function: see data table, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F)
-50 °C (-58 °F) on requestpa

Buzzer 60 dB, Polyamide (PA) enclosure, Ex eb and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66, Bottom face cable gland polyamide, 1x M20, Function: buzzer, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F) @ T4
-40 ... 40 °C (-40 ... 104 °F) @ T6, Enclosure: Polyamide (PA), Marking: [exsign] II 2 GD
Ex eb ib mb IIC T* Gb
Ex tb IIIC T** °C Db
T4/T130 °C @ Ta +55 °C
( T6/T80 °C @ Ta +40 °C on request )pa

Buzzer, flashing red, 60 dB, Polyamide (PA) enclosure, Ex eb and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66, Bottom face cable gland polyamide, 1x M20, Function: flashing buzzer, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F) @ T4
-40 ... 40 °C (-40 ... 104 °F) @ T6, Enclosure: Polyamide (PA), Marking: [exsign] II 2 GD
Ex eb ib mb IIC T* Gb
Ex tb IIIC T** °C Db
T4/T130 °C @ Ta +55 °C
( T6/T80 °C @ Ta +40 °C on request )pa

Double pushbutton, red/green - 1x NO / 1x NC - labeling '0 - l', Polyamide (PA) enclosure, Ex db eb and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Pushbutton with interchangeable inserts, Degree of protection IP66, Bottom face cable gland polyamide, 1x M20, Function: double pushbutton, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F) @ T4
-40 ... 40 °C (-40 ... 104 °F) @ T6, Enclosure: Polyamide (PA)pa

Double pushbutton, red/green - 1x NO / 1x NC - labeling '0 - l', Polyamide (PA) enclosure, Ex db eb and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Pushbutton with interchangeable inserts, Degree of protection IP66, Bottom face cable gland polyamide, 1x M25, Function: double pushbutton, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F) @ T4
-40 ... 40 °C (-40 ... 104 °F) @ T6, Enclosure: Polyamide (PA)pa

Double pushbutton, red/green - 1x NO / 1x NC - labeling '0 - l', Polyamide (PA) enclosure, Ex db eb and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Pushbutton with interchangeable inserts, Degree of protection IP66, Top face stopping plug polyamide, 1x M20; bottom face cable gland polyamide, 1x M20, Function: double pushbutton, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F) @ T4
-40 ... 40 °C (-40 ... 104 °F) @ T6, Enclosure: Polyamide (PA)pa

Emergency stop mushroom button 40 mm, red, twist-to-release - 2x NC, Polyamide (PA) enclosure, Ex db eb and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66, Bottom face cable gland polyamide, 1x M20, Function: mushroom button, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F) @ T4
-40 ... 40 °C (-40 ... 104 °F) @ T6, Enclosure: Polyamide (PA)pa

Emergency stop mushroom button 40 mm, red, twist-to-release - 2x NC, Polyamide (PA) enclosure, Ex db eb and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66, Bottom face cable gland polyamide, 1x M25, Function: mushroom button, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F) @ T4
-40 ... 40 °C (-40 ... 104 °F) @ T6, Enclosure: Polyamide (PA)pa

Emergency stop mushroom button 40 mm, red, twist-to-release - 2x NC, Polyamide (PA) enclosure, Ex db eb and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66, Top face stopping plug polyamide, 1x M20; bottom face cable gland polyamide, 1x M20, Function: mushroom button, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F) @ T4
-40 ... 40 °C (-40 ... 104 °F) @ T6, Enclosure: Polyamide (PA)pa
Sonraki SayfaSon Sayfa

Filtrele