Not available for purchase: 1-channel isolated barrier, 24 V DC supply, Resistance and RTD input (Pt100, Pt500, Pt1000), Resistance output, Accuracy 0.1 %, Line fault detection (LFD) for Pt100, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Transfer direction: to the control system, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC bus powered via Termination Board, Field device: resistance thermometer, Signal: Resistance, Line fault detection, Signal: 1 x Resistancepa
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (bus powered), Voltage input 0 V ... -20 V, Vibration sensor inputs, Voltage/current field supply, Voltage output 0 V ... -20 V, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Transfer direction: to the control system, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20.4 ... 30 V DC bus powered via Termination Board, Field device: vibration sensor, Field device [2]: Acceleration sensor, Signal: 1 x 0 ... -20 Vpa
Not available for purchase: 2-channel isolated barrier, 24 V DC supply (bus powered), 2-wire SMART transmitters or current sources, Usable as signal splitter (1 input and 2 outputs), Dual output 4 mA ... 20 mA or 1 V ... 5 V, Line fault detection (LFD), Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 18 mm, Number of channels: 2-channel, HART communication, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC bus powered via Termination Board, Field device: 2-wire transmitterpa
Not available for purchase: 2-channel isolated barrier, 24 V DC supply (bus powered), Thermocouple, RTD or potentiometer input, Usable as signal splitter (1 input and 2 outputs), Linearized output 4 mA ... 20 mA, sink/source or 1 V ... 5 V, Sensor breakage detection, Configurable by PACTware, Line fault detection (LFD), Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 18 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20.4 ... 30 V DC bus powered via Termination Boardpa
Not available for purchase: 2-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 40 mA at 12 V DC, 55 mA current limit, Contact or logic control input, Entity parameter Io/Isc = 110 mA, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508 (bus powered), Up to SIL 3 acc. to IEC 61508 (loop powered), Housing width: 18 mm, Number of channels: 2-channel, Filter, Safety Integrity Level (SIL): SIL 3pa
Not available for purchase: 2-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 40 mA at 12 V DC, 55 mA current limit, Contact or logic control input, Entity parameter Io/Isc = 110 mA, Line fault detection (LFD), Up to SIL 2 acc. to IEC/EN 61508 (bus powered), Up to SIL 3 acc. to IEC/EN 61508 (loop powered), Housing width: 18 mm, Number of channels: 2-channel, Filter, Safety Integrity Level (SIL): SIL 3pa
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 12 V DC, Housing width 12.5 mm, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 3, Rated voltage: loop powered, Type: field device supply, Field device: 1 x Valve, Field device [2]: 1 x audible alarm, Field device [3]: 1 x visual alarm, Current: ≤ 45 mA, Voltage: ≥ 12 Vpa
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters, Output for 4 mA ... 20 mA or 1 V ... 5 V, Housing width 12.5 mm, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, HART communication, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Field device: 2-wire transmitter, Signal: 0/4 ... 20 mA, Signal: 1 x 0/4 ... 20 mA (current source)pa
Not available for purchase: 1-channel signal conditioner, 24 V DC supply (Power Rail), Level sensing input, Adjustable range 1 kΩ ... 30 kΩ, Relay contact output, Minimum/maximum control, Housing width: 20 mm, Number of channels: 1-channel, Conductivity measurement, Min./max. control, Rated voltage: 20 ... 30 V DC, Signal: Resistance, Type: 1 x relay (change-over contact)pa
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, voltage or current input, 2 relay contact outputs, Programmable high/low alarm, Configurable by PACTware, Sensor breakage detection, Housing width: 20 mm, Number of channels: 1-channel, Trip relay, Programmable high/low alarm, Rated voltage: 19 ... 35 V DC, Field device: resistance thermometer, Field device [2]: Thermocouple, Signal: 0/2 ... 10 V, Signal [2]: 0/4 ... 20 mA, Type: 2 x relay (change-over contact)pa
The USi-safety ultrasonic sensor system is breaking new ground for safety applications—whether in challenging, dusty environments or in outdoor areas Learn more about the USi-safety ultrasonic sensor system ... in Accordance with Category 3 PL d Ultrasonic Technology for Safety in All Areas The USi-safety ultrasonic sensor system is breaking new ground for safety applications—whether in challenging, dusty environments or in outdoor areas. Machines and vehicles can ...
In autonomous transport, the direction of travel and the side areas of AGVs must be monitored in order to avoid any collision with people and objects The USi-safety ultrasonic sensor systems reliably detect all obstacles in a defined safety area ... standard, category 3 PL d . The Solution USi-safety ultrasonic sensor system Several USi-safety ultrasonic sensors are distributed on each side of the vehicle. The very compact sensor unit can be mounted in places where other types of sensor would not fit ...
Whether on-road or off-road, sensors used in mobile equipment must work reliably in harsh conditions Pepperl+Fuchs offers a broad portfolio of sensor solutions for mobile machines ... is ideally suited for challenging outdoor applications with safety requirements. A miniature sensor unit detached from the control interface allows the USi-safety to be used even in confined installations. Collision Avoidance Mobile machines ...
From reliable positioning and identification to guaranteeing smooth processes in conveyor technology and safety-critical applications—discover our comprehensive portfolio for the automotive industry ... in Accordance with Category 3 PL d The USi-safety ultrasonic sensor system is breaking new ground for safety applications—whether in challenging, dusty environments or in outdoor areas. Machines and vehicles can be reliably protected using state-of-the-art ...
Pepperl+Fuchs offers a broad portfolio of sensors and systems that can be used for environment perception in AGV applications Learn more ... , the vehicles must be safeguarded in accordance with ISO 13849-1 category 3 to PL d. The USi-safety is the only ultrasonic sensor system in the world to have this safety approval. It enables reliable monitoring of three-dimensional spaces. Reliable Lateral ...
1-5/13Items Per Page:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.