100 V AC to 240 V AC wide-range input, Output 12 V DC, 16 A, 192 W, 1-phase, Housing width 39 mm, Efficiency up to 94.3 %, Minimal inrush current surge, Remote control for ON/OFF, DC OK relay contact, Suitable for Zone 2/Div. 2 mounting, Device type: device for DIN rail mounting, Function: Standard, Rated voltage: 12 V DC, Voltage range: 12 ... 15 V DC factory setting: 12 Vpa
100 V AC to 240 V AC wide-range input, Output 24 V DC, 5 A, 120 W, 1-phase, Housing width 32 mm, Efficiency up to 94.3 %, Minimal inrush current surge, DC OK relay contact, Suitable for Zone 2/Div. 2 mounting, Device type: device for DIN rail mounting, Function: Standard, Rated voltage: 24 V DC, Voltage range: 24 ... 28 V DC factory setting: 24.1 Vpa
380 V AC to 480 V AC wide-range inputs, Output 24 V DC, 40 A, 960 W, 3-phase, Housing width 110 mm, Efficiency up to 95.3 %, Minimal inrush current surge, Shutdown input, Remote control for ON/OFF, DC OK relay contact, Current sharing for parallel use, Device type: device for DIN rail mounting, Function: Standard, Rated voltage: 24 V DC, Voltage range: 24 ... 28 V DC factory setting: 24.1 Vpa
24 V DC to 28 V DC input, 2 inputs with 1 output, Output 24 V DC, 20 A, Housing width 32 mm, Built-in decoupling mosfets for 1+1 and N+1 redundancy, Automatic load sharing, Reverse input polarity protection, Easy wiring: distribution terminal for negative pole included, Redundancy status indicator, Suitable for Zone 2/Div. 2 mounting, Device type: device for DIN rail mounting, Function: Redundancy Module, Voltage range: 24 ... 28 V DCpa
100 V AC to 240 V AC wide-range input, Output 24 V DC, 10 A, 240 W, 1-phase, Housing width 39 mm, Efficiency up to 95.2 %, Minimal inrush current surge, DC OK relay contact, Suitable for Zone 2/Div. 2 mounting, Device type: device for DIN rail mounting, Function: Standard, Rated voltage: 24 V DC, Voltage range: 24 ... 28 V DC factory setting: 24.1 Vpa
100 V AC to 240 V AC wide-range input, Output 24 V DC, 10 A, 240 W, 1-phase, Housing width 39 mm, Built-in decoupling mosfet for 1+1 and N+1 redundancy, Efficiency up to 94.7 %, Minimal inrush current surge, DC OK relay contact, Current sharing for parallel use, Suitable for Zone 2/Div. 2 mounting, Device type: device for DIN rail mounting, Function: redundancy, Rated voltage: 24 V DC, Voltage range: 23.8 ... 25.2 V DC factory setting: 24.1 Vpa
100 V AC to 240 V AC wide-range input, Output 24 V DC, 20 A, 480 W, 1-phase, Housing width 48 mm, Efficiency up to 95.6 %, Minimal inrush current surge, DC OK relay contact, Current sharing for parallel use, Suitable for Zone 2/Div. 2 mounting, Device type: device for DIN rail mounting, Function: Standard, Rated voltage: 24 V DC, Voltage range: 24 ... 28 V DC factory setting: 24.1 Vpa
100 V AC to 240 V AC wide-range input, Output 24 V DC, 20 A, 480 W, 1-phase, Housing width 48 mm, Built-in decoupling mosfet for 1+1 and N+1 redundancy, Efficiency up to 95.2 %, Minimal inrush current surge, DC OK relay contact, Current sharing for parallel use, Suitable for Zone 2/Div. 2 mounting, Device type: device for DIN rail mounting, Function: redundancy, Rated voltage: 24 V DC, Voltage range: 23.8 ... 25.2 V DC factory setting: 24.1 Vpa
100 V AC to 240 V AC wide-range input, Output 48 V DC, 5.4 A, 260 W, 1-phase, Housing width 39 mm, Efficiency up to 95.5 %, Minimal inrush current surge, DC OK relay contact, Suitable for Zone 2/Div. 2 mounting, Device type: device for DIN rail mounting, Function: Standard, Rated voltage: 48 V DC, Voltage range: 48 ... 56 V DC factory setting: 48 Vpa
24 V DC input, Isolated output 24 V DC, 10 A, 240 W, Housing width 42 mm, Efficiency up to 94.2 %, Minimal inrush current surge, Reverse input polarity protection, 20 % output power reserves, Device type: device for DIN rail mounting, Function: Standard, Voltage range: 24 ... 28 V DC factory setting: 24.1 Vpa
Group Overview: Industrial power supplies combine optimal interference resistance and high efficiency with durability and reliability Discover the the PS industrial power supplies for industrial envi ... redundancy, and with IO-Link interface. Some of their outstanding features are their high efficiency of typically more than 95 %, compact size, and low weight. PS1000 series modules can be used in environments of up to +70 °C. PS3500 Series PS3500 series ...
Group Overview: Pepperl+Fuchs' power supplies provide reliable power in hazardous areas ... . Power Hub is a motherboard-based power supply system for one to four FOUNDATION Fieldbus H1 or PROFIBUS PA segments. PS Industrial Power Supplies The PS1000 and PS3500 power supplies serve as ideal solutions for supplying devices inside control cabinets ...
Download the latest brochures and flyers on the various components and solutions for electrical explosion protection from Pepperl+Fuchs ... . Product Overview PS1000 for Global Use up to Zone 2/Div. 2 Download Now Industrial power supplies are universally applicable. They serve as an ideal solution for supplying devices inside control cabinets. The PS1000 series provides an interruption-free ...