Area scanner FLT-D/38a sw

FLT-D/38a sw
  • Sensor for opening and protecting automatic doors
  • Can be adjusted to the environment through a variety of adjustment options
  • 20 programmable monitoring fields
  • Test input

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  FLT-D/38a sw

Product Description
Combination sensor for opening and protection
General specifications
Detection fieldprogrammable , total field: 2200 mm x 1500 mm (WxD) for a mounting height of 2200 mm , measured using a horizontal test body 200 x 300 x 700 mm
Light source10 IRED 950 nm
Light typemodulated infrared light
Setting angle-6 ... 9 ° for a mounting height of 2200 mm
Open timeprogrammable
Indicators/operating means
Function indicatorLED red: on for object detection, flashes during teaching phase
Control elementsProgrammble switch for switching type, open time, detection field
Parameterization indicator5 LED, red
Electrical specifications
Operating voltage12 ... 31 V DC / 12 ... 30 V AC
No-load supply current≤ 100 mA
Power consumption3.5 VA
Input
Test inputactive with +UB
Output
Switching typelight/dark on selectable programmable
Signal outputRelay, 1 alternator
Switching voltageAC : 30 V ; DC : 32 V
Switching current300 mA
Switching power55 VA
Response time≤ 110 ms
Compliance with standards and directives
Directive conformity
EMC Directive 2004/108/ECEN 61000-6-1 EN 61000-6-2 without EN 61000-4-5, EN 61000-4-11 , EN 61000-6-3 , EN 61000-6-4
Standard conformity
StandardsEN 60947-5-2:2007
IEC 60947-5-2:2007
ANSI 156,10 (as activation sensor)
Approvals and certificates
UL approvalUL
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature-30 ... 75 °C (-22 ... 167 °F)
Mechanical specifications
Mounting heightmax. 2200 mm
Degree of protectionIP54 (when mounted)
Connectionterminal strip 8-pin 1 ... 1.5 mm2
Material
HousingPC
Optical facePC
CoveringASA , black
Mass195 g
Dimensions
Height60 mm
Width250 mm
Depth45 mm
NoteSafety fuse ≤ 315 mA (slow-blow) according to IEC 60127-2 Sheet 1
Recommendation: after a short circuit, check that the device is functioning correctly.

Classifications

SystemClasscode
ECLASS 13.027270913
ECLASS 12.027270913
ECLASS 11.027270913
ECLASS 10.0.127270913
ECLASS 9.027270913
ECLASS 8.027270913
ECLASS 5.127270903
ETIM 9.0EC002550
ETIM 8.0EC002550
ETIM 7.0EC002550
ETIM 6.0EC002550
ETIM 5.0EC001821
UNSPSC 12.139121528

Details: FLT-D/38a sw

Informative Literature: FLT-D/38a sw

Language Selection:
We are sorry, there are no documents for your language selection. Please select another language.

Product Documentation: FLT-D/38a sw

Language Selection:
ManualsLanguageFile TypeFile Size
Instruction Manual Area scanner FLT-D / Betriebsanleitung Flächenlichttaster FLT-DALLPDF5544 KB

Design / Simulation: FLT-D/38a sw

Language Selection:
CADLanguageFile TypeFile Size
CAD 3-D / CAD 3-DALLSTP84 KB