Serviceline Industrial Sensors
Phone: 330-486-0001
Fax: 330-405-4710
Serviceline Explosion Protection
Phone: 330-486-0002
Fax: 330-963-5827

Inductive ring sensor RC10-14-N0

  • 10 mm inside diameter
Unit Price:  115.00  USD
 in stock

NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below:

Download the complete datasheet as a PDF:

Datasheet excerpt: Technical data of RC10-14-N0

General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Inside diameter10 mm
Measuring cylinder9S20K
Diameter2.5 mm
Length4 mm
Output type2-wire
Nominal ratings
Nominal voltage8.2 V (Ri approx. 1 kΩ)
Operating voltage5 ... 25 V
Switching frequency0 ... 2000 Hz
Suitable for 2:1 technologyyes , Reverse polarity protection diode not required
Current consumption
Measuring plate not detectedmin. 3 mA
at maximum permissible ambient temperature, the current consumption can drop to 1.6 mA
Measuring plate detected≤ 1 mA
Functional safety related parameters
MTTFd6150 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
Electromagnetic compatibilityNE 21:2007
StandardsEN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
FM approval
Control drawing116-0165F
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
Ambient conditions
Ambient temperature-20 ... 65 °C (-4 ... 149 °F)
Mechanical specifications
Connection typecable PVC , 2 m
Core cross-section0.14 mm2
Housing materialPBT
Degree of protectionIP67
Bending radius> 10 x cable diameter
Mass36 g
Equipment protection level Gb
CE marking[*PD-Z02585A*]
Effective internal inductivitymax. 150 nF ; a cable length of 10 m is considered.
Effective internal inductancemax. 100 µH ; a cable length of 10 m is considered.
Maximum permissible ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate.
General information
Use in the hazardous areasee instruction manuals

Documents: RC10-14-N0

Instructions, short instructions, safety informationLanguageFile TypeFile Size
Instruction manualENGPDF53 KB
Manuel d'instructionsFRAPDF52 KB
BetriebsanleitungGERPDF55 KB
Manuale di istruzioniITAPDF50 KB
Manual de instruccionesSPAPDF52 KB

Approvals+Certificates: RC10-14-N0

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of conformity / EU-KonformitätserklärungDOC-1251PDF169 KB
US CA CSA1007121 (LR96321-2)PDF101 KB
US CA UL General PurposeE87056LINK---
Control drawings
Control Drawing FM / Control Drawing FM   PDF686 KB