Serviceline Industrial Sensors
Phone: 330-486-0001
Fax: 330-405-4710
Serviceline Explosion Protection
Phone: 330-486-0002
Fax: 330-963-5827

Universal DTM DTM Generic HART

DTM Generic HART
  • Device DTM
  • For HART multiplexers
  • Communication DTM

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  DTM Generic HART

Product Description
Device type manager (DTM) for HART communication
General specifications
DescriptionUniversal DTM for parameterization of individual HART sensors via "universal" commands and "common practice" commands (manufacturer: ICS)*
* Note: DTMs only work in conjunction with FDT frame application e. g. PACTware.
Software
Hardware requirements- processor min. 500 MHz
- working memory: min. 256 MB
- hard disk space: min. 200 MB
- graphic resolution 1024 x 768
Depending on the complexity of the project and the DTMs used, the memory requirement may be several times higher.
Software requirementsoperating system:
- Microsoft Windows 7, Windows 8 or Windows 10
internet browser:
- Microsoft Internet Explorer 4.0 or higher
software components for installation
- Microsoft .Net Framework 3.5 or higher
- FDT framework program PACTware 5.X
- the application-specific device type manager
LanguagesGerman, English, French, Spanish, Russian can be selected
LicensingThe Pepperl+Fuchs DTM-Collections can be downloaded separately or altogether in a version with basic license. This version can also be obtained on CD-ROM from Pepperl+Fuchs.

Basic license:
The software remains a basic version after installation under the terms of a basic license that may have limited features. The basic license is delivered free of charge.

Full license:
The full license can only be activated by an individual license key number and transfers a basic version of software to a full version under the term of a full license. The software under these terms can be installed on more than one workstation simultaneously. The full licenses with the functionality quoted in the following can be ordered at Pepperl+Fuchs.
InstallationAdministrator rights are required For installation in Windows.
Configuration
Representation of the system configurationGraphic representation of all communication and device type managers in the tree structure. In case of online operation colour code for identification of defective units and simulation operation. Multiple windows can be opened simultaneously. It is therefore possible to view the set device parameters, to monitor the measurement value and to display the device diagnostic simultaneously.
System planning, application processingGeneration of a configuration by means of a graphical application processing menu. Editing of available projects. Selection switch markings for each channel. Offline configuration, saving of project data to hard disk. Automatic comparison of the project plan to the actual available system when establishing connections on the device and parameter levels.

Classifications

SystemClasscode
ECLASS 13.027242505
ECLASS 12.027242502
ECLASS 11.027242502
ECLASS 10.0.127242502
ECLASS 9.027242502
ECLASS 8.027242502
ECLASS 5.127242502
ETIM 9.0EC000757
ETIM 8.0EC001416
ETIM 7.0EC001416
ETIM 6.0EC001416
ETIM 5.0EC000809
UNSPSC 12.143232901

Details: DTM Generic HART

Function

  • Based on FDT technology

  • Device Type Manager (DTMs) available for all Pepperl+Fuchs devices and systems

  • Commissioning, configuration and parameter assignment independent of the process control system

  • Communication DTMs available for serial interfaces and fieldbus systems

  • Maintenance, diagnostics and error correction

  • In accordance with VDI/VDE 2187

Software: DTM Generic HART

Language Selection:
Device Description Files/DriversRelease InfoFile TypeFile Size
Generic HART DTM / Generic HART DTM4.0.3ZIP7197 KB

Associated Products: DTM Generic HART

Accessory of

2,942.00  USD

Contact Us

32-channel, 24 V DC supply, HART field device input (revision 5 to 7), RS-485 interface, Up to SIL 3 acc. to IEC/EN 61508pa
Interface for wireless communication between PC host and HART field devices, Interface for wireless communication between PC host and any HART field device, Registered with HART Communication Foundation, Powerful, high-speed Bluetooth with 100 m open-air range, Adaptive frequency hopping to reduce radio-frequency interference, HARTCommDTM software supports use with FDT Frame applications, Compatible with 32- and 64-bit Windows® 7, 8, XP, 10, or Vistapa
563.00  USD

Contact Us

Interface for commissioning, calibrating, and acquiring data from HART field devices, HART compliant for communication with any HART field device and error-free slave testing, Draws power from USB port, needs no external supply to power modem, Compact, rugged polycarbonate housing for industrial-grade reliability, USB 1.1 compliant, Integrated connector cable terminates in 2 test clips and 1 USB connector cable, Polarity insensitive test clipspa
Interface for communication with HART field devices, HART compliant for communication with any HART field device and error-free slave testing, Easy installation, Draws power from RS-232 port, needs no external supply to power modem, Compact, rugged polycarbonate housing for industrial-grade reliability, Polarity insensitive test clips, Transformer isolation allows you to connect the interface across the load resistor or the field device, Compatible with 32- and 64-bit Windows® XP, Vista, 7 and 10pa
816.00  USD

Contact Us

Interface for commissioning, calibrating, and acquiring data from HART field devices, Quickly power and communicate with HART field devices, Powers all 2-wire HART devices, independent of supplier, Draws power from USB port, needs no external supply to power modem, Compact, rugged polycarbonate housing for industrial-grade reliability, Integrated connector cable terminates in 2 test clips and 1 USB connector cable, Selectable powered-modem or modem-only modepa
502.00  USD

Contact Us

Interface for communication with HART field devices, HART compliant for communication with any HART field device and error-free slave testing, Easy installation, Draws power from RS-232 port, needs no external supply to power modem, Compact, rugged polycarbonate housing for industrial-grade reliability, Polarity insensitive test clips, Transformer isolation allows you to connect the interface across the load resistor or the field device, Compatible with 32- and 64-bit Windows® 7, 8, XP, 10, or Vistapa
Interface for wireless communication between PC host and HART field devices, Interface for wireless communication between PC host and any HART field device, Registered with HART Communication Foundation, ATEX and IECEx approval, UL listed for North America, Powerful, high-speed Bluetooth with 100 m open-air range, Adaptive frequency hopping to reduce radio-frequency interference, HARTCommDTM software supports use with FDT Frame applicationspa
Matching System Components
2 x 16-channel, 24 V DC supply, Suitable for HART communication, Dual RS 485 connections, Used with HiC Termination Boards, LED indicator for supply status, Splitting: 2 x 16pa
4 x 8-channel, 24 V DC supply, Suitable for HART communication, Dual RS 485 connections, Used with HiC Termination Boards, LED indicator for supply status, Splitting: 4 x 8pa
16-channel, 24 V DC supply (Power Rail), HART field device input (revision 5 to 7), Up to 15 KFD0-HMS-16 slave units can be connected, Up to SIL 3 acc. to IEC/EN 61508pa
4 x 8-channel, 24 V DC supply, Suitable for HART communication, Dual RS 485 connections, Used with HiC Termination Boards, LED indicator for supply status, Splitting: 4 x 8pa
679.00  USD

Contact Us

16-channel, No external power required, HART field device input (revision 5 to 7), Used with HART Multiplexer Master KFD2-HMM-16, Up to SIL 3 acc. to IEC/EN 61508pa
Accessories
Universal DTM host platform, For all DTMs of Pepperl+Fuchs, Approved FDT/DTM technology, Free of charge, Internet download possiblepa
Universal DTM host platform, For all DTMs of Pepperl+Fuchs, Approved FDT/DTM technology, Free of charge, Download from Pepperl+Fuchs websitepa
Software for connecting people, information, systems, and devices, For applications developed using .NET, Required to run PACTwarepa