Serviceline Industrial Sensors
Phone: 330-486-0001
Fax: 330-405-4710
Serviceline Explosion Protection
Phone: 330-486-0002
Fax: 330-963-5827

Multifunction Terminal MFT-2L.1600

MFT-2L.1600
  • Suitable for fusing solenoids, alarm indicators, sounders etc, and diode decoupling of power supplies
  • Simple OR gate for zone 1 mounting, visible separation for field devices, relay switches
  • Bus termination
  • Current limiting
  • DIN rail mounting
  • Maintenance without hot work permit
  • Wires can be disconnected during operation once the module has been removed
    (parts under voltage remain covered)

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  MFT-2L.1600

Product Description
Multifunction terminal, 4-pin, 2 x bridges
General specifications
FunctionThe specific device function can be found in the ordering information section.
Electrical specifications
Resistor1 x 1 Ω ... 22 MΩ, 0.5 W
2 x 1 Ω ... 22 MΩ, 0.5 W
Diode1 x I max. 1 A
2 x I max. 0.5 A
Fuse0.032 ... 1.5 A
1.5 ... 6.3 A
Pre-arcing time/current characteristic: time-lag T
Nominal voltagemax. 250 V AC max. 30 V DC
Relay
Control24 V , approx. 5 ... 8.5 mA
Contact loadingAC max. 250 V , max. 1 A
DC max. 30 V , max. 1 A
Contact resistance0.1 Ω at 6 V, 1 A
Switching operations NO contact3 x 104
Switching operations NC contact1 x 104
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Conformity
Degree of protectionIEC 60529:2001
Ambient conditions
Ambient temperature-55 ... 70 °C (-67 ... 158 °F)
Mechanical specifications
Core cross section0.5 ... 2.5 mm2
Degree of protectionIP20 , IP30 when plug-in module is plugged in
Massapprox. 115 g , depending on model
Dimensions93 x 17.5 x 79 mm (l x w x h)
Tightening torque0.5 ... 1 Nm
Data for application in connection with hazardous areas
EU-type examination certificatePTB 07 ATEX 1004 U
MarkingEx-Hexagon II 2 G Ex d e IIC
Directive conformity
Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-1:2014 , EN 60079-7:2015+A1:2018
International approvals
IECEx approval
IECEx certificateIECEx BKI 08.0008U
IECEx markingEx d e IIC Gb
Marine approval
DNV GL MarineTAA0000034
General information
Ordering informationCustomer-specific values are available in the E96 series.
Minimum order quantity 50 pieces.
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027210192
ECLASS 12.027210192
ECLASS 11.027210192
ECLASS 10.0.127210190
ECLASS 9.027210190
ECLASS 8.027210190
ECLASS 5.127242692
ETIM 9.0EC003015
ETIM 8.0EC003015
ETIM 7.0EC003015
ETIM 6.0EC003015
ETIM 5.0EC001485
UNSPSC 12.139121008

Details: MFT-2L.1600

Function

The multifunction terminal allows maintenance without a hot work permit in a hazardous area.

It employs a 2-step removal process, which guarantees that a potentially formed ignition spark remains inside the flameproof enclosure when lifting off a module and thus makes sure that the ignition spark has extinguished and the module is volt-free.

Product Documentation: MFT-2L.1600

Language Selection:
Safety and Security DocumentationLanguageFile TypeFile Size
Instruction manualENGPDF166 KB
Manuals
ManualENGPDF2766 KB

Design / Simulation: MFT-2L.1600

Language Selection:
CADLanguageFile TypeFile Size
CAD 3-D / CAD 3-DALLSTP2318 KB
CAE
CAE EPLAN Data Portal / CAE EPLAN Data PortalALLLINK---
CAE EPLAN macro EDZ / CAE EPLAN Makro EDZALLEDZ41 KB
EPLAN macros MFT / EPLAN-Makros MFTALLZIP11723 KB

Approvals: MFT-2L.1600

Language Selection:
CertificatesCertificate No.LanguageFile TypeFile Size
BKI IECEx Certificate of ConformityIECEx BKI 08.0008UALLLINK---
Brasil TUV Rheinland BrazilTÜV 13.1133 UALLPDF1220 KB
Bureau Veritas (Maritime) Marine22449/C0 BVALLPDF590 KB
DNV MarineTAA0000034ALLPDF110 KB
Europe PTB ATEX Category 2 GPTB 07 ATEX 1004UALLPDF1206 KB
Lloyd's Register MarineLR2003616TA-02ALLPDF557 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-0746DALLPDF358 KB

Associated Products: MFT-2L.1600

Accessory of
FieldConnex® FieldBarrier®, 8 ... 12 outputs Ex ia IIC, FISCO and Entity, Advanced fault isolation and diagnostics at the spur, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0...1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Dust protection, International, Europe, USA, Device coupler location: Zone 2 - high-power trunk
Zone 1 - high-power trunk
Division 2 - high-power trunk
Division 1 - high-power trunkpa
Accessories
pa
Specifications
Suitable for fusing solenoids, alarm indicators, sounders etc, and diode decoupling of power supplies, Simple OR gate for zone 1 mounting, visible separation for field devices, relay switches , Bus termination, Current limiting, DIN rail mounting, Maintenance without hot work permit, Wires can be disconnected during operation once the module has been removed
(parts under voltage remain covered)pa