Control interface unit IC-KP2-2HB6-V15B

IC-KP2-2HB6-V15B
  • LED status indicator of bus communication and read/write heads
  • Max. 2 read/write heads can be connected
  • Alternatively 1 read/write head and 1 trigger sensor can be connected

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH, also apply to Pepperl+Fuchs AG.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  IC-KP2-2HB6-V15B

Product Description
Control interface unit IDENTControl Compact
with PROFIBUS DP interface
General specifications
Number of read/write headsmax. 2
alternatively 1 read/write head and 1 trigger sensor
UL File NumberE87056
Indicators/operating means
LED BUSgreen: Slave is at state "Data Exchange"
red: Bus error
LED DiagNo function
LEDs 1, 2Status indicator for read/write heads
green: command at read/write head active
yellow: approx. 1 second long, if command was successfully executed
LEDs CH1, CH2green: read head detected
red: Configuration error
LED PWR/ERRgreen: power on
red: Hardware fault
Rotary switchAddress setting 00 ... 7E, FF (hexadecimal)
BUS Address (high nibble): 0 ... 7, F
BUS Address (low nibble): 0 ... F
Electrical specifications
Rated operating voltage20 ... 30 V DC , PELV
Ripple≤ 10 % at 30 V DC
Current consumption≤ 4 A incl. read/write heads
Power consumption2 W Without read/write heads
Galvanic isolationbasic insulation acc. to DIN EN 50178, rated insulation voltage of 50 Veff
Interface 1
Interface typePROFIBUS
Physical RS-485
ProtocolPROFIBUS DP acc. to EN 50170
Transfer rate9.6; 19.2; 93.75; 187.5; 500; 1500 kBit/s
3; 6; 12 Mbit/s self-synchronizing
Interface 2
Interface typeDiagnostic Interface
Physical RS 232
ProtocolASCII
Transfer rate38.4 kBit/s
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61000-6-2:2005, EN 61000-6-4:2007
Standard conformity
Degree of protectionIEC 60529:2001
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Climatic conditionsair humidity max. 96 %
Salt spray resistant to EN 60068-2-52
Shock and impact resistanceOscillation (Sine): 5 g, 10 - 1000 Hz to EN 60068-2-6
Shock (Half-sine): 30 g, 11 ms in accordance with EN 60068-2-27
Mechanical specifications
Degree of protectionIP67
ConnectionRead/write heads: shielded, 4-pin, M12 connector
Power supply: M12 connector
Protective earth: M4 earthing screw
Diagnostic RS 232: M12 connector
PROFIBUS: M12 connector, B-coded
Material
Housingpowder coated aluminum
Installationscrew fixing
Massapprox. 300 g

Documents: IC-KP2-2HB6-V15B

ManualsLanguageFile TypeFile Size
Manual IC-KP2-2HB6-V15BENGPDF1514 KB
Manual Read / Write Ranges and Passing Speeds RFIDENGPDF3640 KB
Handbuch IC-KP2-2HB6-V15BGERPDF1518 KB
Handbuch Schreib- und Leseabstände und Vorbeifahrgeschwindigkeiten RFIDGERPDF3642 KB
Short instructions, safety information
Quick Start Guide IC-KP2-*ENGPDF2285 KB
Kurzanleitung IC-KP2-*GERPDF2341 KB

Approvals+Certificates: IC-KP2-2HB6-V15B

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of conformity / EU-KonformitätserklärungDOC-0687CPDF163 KB
Certificates
Korea Radio ApprovalMSIP-REI-PF1-ICKP22HB6V15BPDF365 KB
Russia TUV GOST-R101-KC/542PDF90 KB
US CA ULE87056LINK---

Commissioning: IC-KP2-2HB6-V15B

Commissioning examplesLanguageFile TypeFile Size
Commissioning IC-KP2-2HB6 with Profinet at S7 PLCENGPDF230 KB
Inbetriebnahme IC-KP2-2HB6 mit PROFIBUS an S7-SteuerungGERPDF234 KB
Commissioning files
Function block Step 7 Classic for the evaluation unit IC-KP2-2HBx with the RFID heads IQH1-...-V1 for complete reading and writing of the IQC21 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP2-2HBx mit den RFID-Köpfen IQH1-...-V1 zum vollständigen Lesen und Schreiben des IQC21 DatenträgersALLZIP2215 KB
Function block Step 7 Classic for the evaluation unit IC-KP2-2HBx with the RFID heads IQH1-...-V1 for complete reading and writing of the IQC22 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP2-2HBx mit den RFID-Köpfen IQH1-...-V1 zum vollständigen Lesen und Schreiben des IQC22 DatenträgersALLZIP2216 KB
Function block Step 7 Classic for the evaluation unit IC-KP2-2HBx with the RFID heads IQH1-...-V1 for complete reading and writing of the IQC24 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP2-2HBx mit den RFID-Köpfen IQH1-...-V1 zum vollständigen Lesen und Schreiben des IQC24 DatenträgersALLZIP2220 KB
Function block Step 7 Classic for the evaluation unit IC-KP2-2HBx with the RFID heads IQH1-...-V1 for complete reading and writing of the IQC33 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP2-2HBx mit den RFID-Köpfen IQH1-...-V1 zum vollständigen Lesen und Schreiben des IQC33 DatenträgersALLZIP2209 KB
Function block Step 7 Classic for the evaluation unit IC-KP2-2HBx with the RFID heads IQH1-...-V1 for complete reading and writing of the IQC35 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP2-2HBx mit den RFID-Köpfen IQH1-...-V1 zum vollständigen Lesen und Schreiben des IQC35 DatenträgersALLZIP2214 KB
Function block Step 7 Classic for the evaluation unit IC-KP2-2HBx with the RFID heads IQH1-...-V1 for reading and writing of the IQC37 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP2-2HBx mit den RFID-Köpfen IQH1-...-V1 zum Lesen und Schreiben des IQC37 DatenträgersALLZIP2219 KB
SIMATIC S7 sample project file for PROFIBUS with IC-KP2-2HB6 / SIMATIC S7 Beispielprojekt für die PROFIBUS-Anbindung mit IC-KP2-2HB6ALLZIP447 KB
Step 7 function block S7-300/400 for IC-KP2-2HB17 (Profinet) and IC-KP2-2HB6 (Profibus) MultiFrame protocol UHF-System / Step 7 Funktionsbaustein S7-300/400 für IC-KP2-2HB17 (Profinet) und IC-KP2-2HB6 (Profibus) MultiFrame Protokoll UHF-SystemALLZIP8387 KB

Software: IC-KP2-2HB6-V15B

DriversRelease InfoFile TypeFile Size
GSD file IC-KP2-xHB6-... / GSD-Datei IC-KP2-xHB6-...06/2009ZIP6 KB

Associated Products: IC-KP2-2HB6-V15B

Accessory of

1,077.00  USD

In stock

Read/write head for IDENTControl, USA, Canada, Mexico, and Argentinafa
Read/Write head for IDENTControl, Europe, Middle East and Africafa
1,997.00  USD

In stock

Read/write head for IDENTControl, USA and Argentinafa
UHF read/write head for IDENTControl, Europefa
UHF read/write head for hazardous areas, for IDENTControl, Canada, USA, and Mexicofa
UHF read/write head for IDENTControl, Moroccofa
Read/Write head for IDENTControl, Asia and the Americas except Canada, United States and Mexicofa
UHF read/write head for IDENTControl, Chinafa
UHF read/write head for IDENTControl, Indiafa
UHF read/write head for IDENTControl, Singapore and Vietnamfa
UHF read/write head for IDENTControl, Russiafa
UHF read/write head for IDENTControl, Brazilfa
UHF read/write head for IDENTControl, Thailand and Hong Kongfa
UHF read/write head for IDENTControl, Malaysiafa
UHF read/write head for IDENTControl, Singapore and Vietnamfa
HF read/write head, ISO 15693, for IDENTControlfa
Accessories
44.00  USD

In stock

Connecting cable, M12 to M12, PUR cable 4-pin, shieldedfa
57.00  USD

In stock

Connecting cable, M12 to M12, PUR cable 4-pin, shieldedfa
Y connection cable for PROFIBUSfa
Terminal cable for PROFIBUS with terminal resistorfa
Bus cable PROFIBUS, M12 to M12, PUR cablefa
Bus cable PROFIBUS, M12 to M12, PUR cablefa
Mounting aid for DIN railfa
Adapter M12 on Sub-D for PC connection with null modem cablefa
Adapter, M12 x 1, to sub-D, 9-pinfa
Visit the RFID Hub

Visit our "RFID Hub"—this special website is a knowledge base for RFID. Get answers on frequently asked questions and learn about typical RFID applications …