Serviceline Industrial Sensors
Phone: 330-486-0001
Fax: 330-405-4710
Serviceline Explosion Protection
Phone: 330-486-0002
Fax: 330-963-5827

Control interface unit IC-KP2-2HB17-2V1D

IC-KP2-2HB17-2V1D
  • LED status indicator of bus communication and read/write heads
  • Network loop through by means of integrated 2 port switch
  • Max. 2 read/write heads can be connected
  • Alternatively 1 read/write head and 1 trigger sensor can be connected
 Please contact the Serviceline for exact delivery estimation
1,440.00 USDUnit Price 

Quantity

Free Shipping

Purchase on Account

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH, also apply to Pepperl+Fuchs AG.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  IC-KP2-2HB17-2V1D

Product Description
IDENTControl Compact control interface
With Ethernet interface for TCP/IP, PROFINET, EtherNet/IP, and MODBUS TCP protocols
General specifications
Number of read/write headsmax. 2
alternatively 1 read/write head and 1 trigger sensor
UL File NumberE87056
Functional safety related parameters
MTTFd140 a
Mission Time (TM)10 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
LED Link/Trafficgreen: network connection
yellow: flashes in rhythm with the transmitted data
LEDs 1, 2Status indicator for read/write heads
green: command at read/write head active
yellow: approx. 1 second long, if command was successfully executed
LEDs CH1, CH2green: read head detected
red: Configuration error
LED PWR/ERRgreen: power on
yellow: system is starting
red: PROFINET bus failure
Rotary switchAddress setting
Electrical specifications
Rated operating voltage20 ... 30 V DC , PELV
Ripple≤ 10 % at 30 V DC
Current consumption≤ 4 A incl. read/write heads
Power consumption3.5 W Without read/write heads
Galvanic isolationbasic insulation acc. to DIN EN 50178, rated insulation voltage of 50 Veff
Interface 1
Physical Ethernet
ProtocolSMTP
HTTP
TCP/IP (Port 10000)
MODBUS/TCP
EtherNet/IP
PROFINET IO
Transfer rate10 MBit/s or 100 MBit/s
Interface 2
Physical Ethernet
ProtocolSMTP
HTTP
TCP/IP (Port 10000)
MODBUS/TCP
EtherNet/IP
PROFINET IO
Transfer rate10 MBit/s or 100 MBit/s
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61000-6-2:2005, EN 61000-6-4:2007
Standard conformity
Degree of protectionIEC 60529:2001
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Climatic conditionsair humidity max. 96 %
Salt spray resistant to EN 60068-2-52
Shock and impact resistanceOscillation (Sine): 5 g, 10 - 1000 Hz to EN 60068-2-6
Shock (Half-sine): 30 g, 11 ms in accordance with EN 60068-2-27
Mechanical specifications
Degree of protectionIP67
ConnectionRead/write heads: shielded, 4-pin, M12 connector
Power supply: M12 connector
Protective earth: M4 earthing screw
Ethernet: M12 plug connection
Material
Housingpowder coated aluminum
Installationscrew fixing
Massapprox. 300 g

Documents: IC-KP2-2HB17-2V1D

ManualsLanguageFile TypeFile Size
Manual IC-KP2-2HB17-2V1DENGPDF3711 KB
Manual Read / Write Ranges and Passing Speeds RFIDENGPDF3640 KB
Handbuch IC-KP2-2HB17-2V1DGERPDF3721 KB
Handbuch Schreib- und Leseabstände und Vorbeifahrgeschwindigkeiten RFIDGERPDF3642 KB
Short instructions, safety information
Quick Start Guide IC-KP2-*ENGPDF2285 KB
Kurzanleitung IC-KP2-*GERPDF2341 KB

Approvals+Certificates: IC-KP2-2HB17-2V1D

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of conformity / EU-KonformitätserklärungDOC-0687CPDF163 KB
Certificates
KoreaKCC-REI-PF1-ICKP22HB172V1DPDF398 KB
Russia TUV GOST-R101-KC/542PDF90 KB
US CA ULE87056LINK---

Commissioning: IC-KP2-2HB17-2V1D

Commissioning examplesLanguageFile TypeFile Size
Commissioning IC-KP2-2HB17 Profinet S7 Multiframe ParameterENGPDF2624 KB
Commissioning IC-KP2-2HB17 Profinet S7 Singleframe ParameterENGPDF2660 KB
Commissioning IC-KP2-2HB17 with Profinet at S7 PLCENGPDF289 KB
Inbetriebnahme IC-KP2-2HB17 Profinet S7 Multiframe ParameterGERPDF1804 KB
Inbetriebnahme IC-KP2-2HB17 Profinet S7 Singleframe ParameterGERPDF2674 KB
Inbetriebnahme IC-KP2-2HB17 mit Profinet an S7-SteuerungGERPDF289 KB
Commissioning files
Function block Step 7 Classic for the evaluation unit IC-KP2-2HBx with the RFID heads IQH1-...-V1 for complete reading and writing of the IQC21 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP2-2HBx mit den RFID-Köpfen IQH1-...-V1 zum vollständigen Lesen und Schreiben des IQC21 DatenträgersALLZIP2215 KB
Function block Step 7 Classic for the evaluation unit IC-KP2-2HBx with the RFID heads IQH1-...-V1 for complete reading and writing of the IQC22 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP2-2HBx mit den RFID-Köpfen IQH1-...-V1 zum vollständigen Lesen und Schreiben des IQC22 DatenträgersALLZIP2216 KB
Function block Step 7 Classic for the evaluation unit IC-KP2-2HBx with the RFID heads IQH1-...-V1 for complete reading and writing of the IQC24 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP2-2HBx mit den RFID-Köpfen IQH1-...-V1 zum vollständigen Lesen und Schreiben des IQC24 DatenträgersALLZIP2220 KB
Function block Step 7 Classic for the evaluation unit IC-KP2-2HBx with the RFID heads IQH1-...-V1 for complete reading and writing of the IQC33 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP2-2HBx mit den RFID-Köpfen IQH1-...-V1 zum vollständigen Lesen und Schreiben des IQC33 DatenträgersALLZIP2209 KB
Function block Step 7 Classic for the evaluation unit IC-KP2-2HBx with the RFID heads IQH1-...-V1 for complete reading and writing of the IQC35 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP2-2HBx mit den RFID-Köpfen IQH1-...-V1 zum vollständigen Lesen und Schreiben des IQC35 DatenträgersALLZIP2214 KB
Function block Step 7 Classic for the evaluation unit IC-KP2-2HBx with the RFID heads IQH1-...-V1 for reading and writing of the IQC37 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP2-2HBx mit den RFID-Köpfen IQH1-...-V1 zum Lesen und Schreiben des IQC37 DatenträgersALLZIP2219 KB
Simatic S7 function block V3.0 Profinet connection IC-KP2-2HB17-2V1D / Simatic S7 Funktionsbaustein V3.0 Profinet Anbindung IC-KP2-2HB17-2V1DALLZIP1231 KB
Step 7 function block S7-300/400 for IC-KP2-2HB17 (Profinet) and IC-KP2-2HB6 (Profibus) MultiFrame protocol UHF-System / Step 7 Funktionsbaustein S7-300/400 für IC-KP2-2HB17 (Profinet) und IC-KP2-2HB6 (Profibus) MultiFrame Protokoll UHF-SystemALLZIP8387 KB
Step 7 function block S7-400 with CP for TCP/IP communication IC-KP2-2HB17-2V1D MultiFrame protocol UHF-System / Step 7 Funktionsbaustein S7-400 mit CP für TCP/IP Kommunikation IC-KP2-2HB17-2V1D MultiFrame Protokoll UHF-SystemALLZIP1295 KB
Step 7 function block S7-400 with CP for TCP/IP communication IC-KP2-2HB17-2V1D SingleFrame protocol UHF-System / Step 7 Funktionsbaustein S7-400 mit CP für TCP/IP Kommunikation IC-KP2-2HB17-2V1D SingleFrame Protokoll UHF-SystemALLZIP1274 KB

Associated Products: IC-KP2-2HB17-2V1D

Accessory of

1,077.00  USD

In stock

Read/write head for IDENTControl, USA, Canada, Mexico, and Argentinafa
Read/Write head for IDENTControl, Europe, Middle East and Africafa
1,997.00  USD

In stock

Read/write head for IDENTControl, USA and Argentinafa
UHF read/write head for IDENTControl, Europefa
UHF read/write head for hazardous areas, for IDENTControl, Canada, USA, and Mexicofa
UHF read/write head for IDENTControl, Moroccofa
Read/Write head for IDENTControl, Asia and the Americas except Canada, United States and Mexicofa
UHF read/write head for IDENTControl, Chinafa
UHF read/write head for IDENTControl, Indiafa
UHF read/write head for IDENTControl, Singapore and Vietnamfa
UHF read/write head for IDENTControl, Russiafa
UHF read/write head for IDENTControl, Brazilfa
UHF read/write head for IDENTControl, Thailand and Hong Kongfa
UHF read/write head for IDENTControl, Malaysiafa
UHF read/write head for IDENTControl, Singapore and Vietnamfa
HF read/write head, ISO 15693, for IDENTControlfa
Accessories
44.00  USD

In stock

Connecting cable, M12 to M12, PUR cable 4-pin, shieldedfa
Mounting aid for DIN railfa
72.00  USD

Contact Us

Connection cable, M12 to RJ-45, PUR cable 4-pin, CAT5efa
Software for RFID identification systemsfa
Visit the RFID Hub

Visit our "RFID Hub"—this special website is a knowledge base for RFID. Get answers on frequently asked questions and learn about typical RFID applications …