Control interface unit IC-KP-B17-AIDA1

IC-KP-B17-AIDA1
  • Max. 4 read/write heads connectable
  • Alternative 2 read/write heads and 2 trigger sensors can be connected
  • LED status indicator of bus communication and read/write heads
  • TCP/IP, MODBUS/TCP, EtherNet/IP and PROFINET IO protocol
  • Connector acc. to AIDA specifications
  • Integrated switch allows line topology
 in stock
2,310.00 USDUnit Price 

Quantity

Free Shipping

Purchase on Account

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH, also apply to Pepperl+Fuchs AG.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  IC-KP-B17-AIDA1

Product Description
IDENTControl control interface
With Ethernet interface for TCP/IP, PROFINET, EtherNet/IP, and MODBUS TCP protocols
General specifications
Number of read/write headsmax. 4
alternative 2 read/write heads and 2 trigger sensors
UL File NumberE87056
Indicators/operating means
LEDs CH1, CH2, CH3, CH4Status indicator for read/write heads
green: command at read/write head active
yellow: approx. 1 second long, if command was successfully executed
LED PWR/ERRgreen: power on
red: PROFINET bus failure
LED Link1/Link2green: network connection
LED Trafficgreen: flashes in rhythm with the transmitted data
LC displaytwo-line multi-function display with 12 characters per line
configuration of the control interface and display of connected read/write heads as additional pictograms; easy and direct selection of operating commands
Button4 keys: ESC, up, down and return
Electrical specifications
Rated operating voltage20 ... 30 V DC , PELV
Ripple≤ 10 % at 30 V DC
Current consumption≤ 8 A incl. read/write heads
Power consumption3.5 W Without read/write heads
Galvanic isolationbasic insulation acc. to DIN EN 50178, rated insulation voltage of 50 Veff
Interface 1
Physical Ethernet
ProtocolSMTP
HTTP
TCP/IP (Port 10000)
MODBUS/TCP
EtherNet/IP
PROFINET IO
Interface 2
Physical Ethernet
ProtocolSMTP
HTTP
TCP/IP (Port 10000)
MODBUS/TCP
EtherNet/IP
PROFINET IO
Transfer rate10 MBit/s or 100 MBit/s
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
Standard conformity
Degree of protectionIEC 60529:2001
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-30 ... 80 °C (-22 ... 176 °F)
Climatic conditionsair humidity max. 96 %
Shock and impact resistanceOscillation (Sine): 5 g, 10 - 1000 Hz to EN 60068-2-6
Shock (Half-sine): 30 g, 11 ms in accordance with EN 60068-2-27
Mechanical specifications
Degree of protectionIP67
ConnectionRead/write heads: shielded, 4-pin, M12 connector
Power supply: MSTB AIDA
Protective earth: M6 earthing screw
Ethernet: RJ-45 AIDA
Material
Housingpowder coated aluminum
Installationsnap-on to 35 mm standard rail or screw fixing
Massapprox. 1000 g

Documents: IC-KP-B17-AIDA1

ManualsLanguageFile TypeFile Size
Manual IC-KP-B17-AIDA1ENGPDF4040 KB
Manual Read / Write Ranges and Passing Speeds RFIDENGPDF3640 KB
Handbuch IC-KP-B17-AIDA1GERPDF4086 KB
Handbuch Schreib- und Leseabstände und Vorbeifahrgeschwindigkeiten RFIDGERPDF3642 KB
Instruction leaflets
Device mounting / GerätemontageALLPDF917 KB
Short instructions, safety information
Quick Start Guide IC-KP-*ENGPDF1019 KB
Kurzanleitung IC-KP-*GERPDF1014 KB

Approvals+Certificates: IC-KP-B17-AIDA1

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of conformity / EU-KonformitätserklärungDOC-1845BPDF162 KB
Certificates
Australia Declaration of ConformityACMA Supplier's declaration of conformityPDF730 KB
Korea Radio ApprovalMSIP-REI-PF1-ICKPB17AIDA1PDF358 KB
US CA ULE87056LINK---

Commissioning: IC-KP-B17-AIDA1

Commissioning examplesLanguageFile TypeFile Size
Commissioning IC-KP-B17-AIDA Profinet S7 Multiframe ParameterENGPDF3442 KB
Commissioning IC-KP-B17-AIDA Profinet S7 Singleframe ParameterENGPDF3044 KB
Inbetriebnahme IC-KP-B17-AIDA Profinet S7 Multiframe ParameterGERPDF3264 KB
Inbetriebnahme IC-KP-B17-AIDA Profinet S7 Singleframe ParameterGERPDF3044 KB
Commissioning files
Function block Step 7 Classic for the evaluation unit IC-KP-Bxx (Profinet + Profibus) with the RFID heads IPH-...-V1 for complete reading and writing of the IPC03 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP-Bxx (Profinet + Profibus) mit den RFID-Köpfen IPH-...-V1 zum vollständigen Lesen und Schreiben des IPC03 DatenträgersALLZIP2184 KB
Function block Step 7 Classic for the evaluation unit IC-KP-Bxx (Profinet + Profibus) with the RFID heads IQH1-...-V1 for complete reading and writing of the IQC21 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP-Bxx (Profinet + Profibus) mit den RFID-Köpfen IQH1-...-V1 zum vollständigen Lesen und Schreiben des IQC21 DatenträgersALLZIP2180 KB
Function block Step 7 Classic for the evaluation unit IC-KP-Bxx (Profinet + Profibus) with the RFID heads IQH1-...-V1 for complete reading and writing of the IQC22 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP-Bxx (Profinet + Profibus) mit den RFID-Köpfen IQH1-...-V1 zum vollständigen Lesen und Schreiben des IQC22 DatenträgersALLZIP2181 KB
Function block Step 7 Classic for the evaluation unit IC-KP-Bxx (Profinet + Profibus) with the RFID heads IQH1-...-V1 for complete reading and writing of the IQC24 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP-Bxx (Profinet + Profibus) mit den RFID-Köpfen IQH1-...-V1 zum vollständigen Lesen und Schreiben des IQC24 DatenträgersALLZIP2182 KB
Function block Step 7 Classic for the evaluation unit IC-KP-Bxx (Profinet + Profibus) with the RFID heads IQH1-...-V1 for complete reading and writing of the IQC33 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP-Bxx (Profinet + Profibus) mit den RFID-Köpfen IQH1-...-V1 zum vollständigen Lesen und Schreiben des IQC33 DatenträgersALLZIP2176 KB
Function block Step 7 Classic for the evaluation unit IC-KP-Bxx (Profinet + Profibus) with the RFID heads IQH1-...-V1 for complete reading and writing of the IQC35 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP-Bxx (Profinet + Profibus) mit den RFID-Köpfen IQH1-...-V1 zum vollständigen Lesen und Schreiben des IQC35 DatenträgersALLZIP2180 KB
Simatic S7 function block V3.0 Profinet connection IC-KP-B17-AIDA1 and IC-KP-B12-V45 / Simatic S7 Funktionsbaustein V3.0 Profinet Anbindung IC-KP-B17-AIDA1 und IC-KP-B12-V45ALLZIP1174 KB
Step 7 function block S7-300/400 for IC-KP-B17 (Profinet) MultiFrame protocol UHF-System / Step 7 Funktionsbaustein S7-300/400 für IC-KP-B17 (Profinet) MultiFrame Protokoll UHF-SystemALLZIP8316 KB
Step 7 function block S7-400 with CP for TCP/IP communication IC-KP-B17-AIDA1 MultiFrame protocol UHF-System / Step 7 Funktionsbaustein S7-400 mit CP für TCP/IP Kommunikation IC-KP-B17-AIDA1 MultiFrame Protokoll UHF-SystemALLZIP1321 KB
Step 7 function block S7-400 with CP for TCP/IP communication IC-KP-B17-AIDA1 SingleFrame protocol UHF-System / Step 7 Funktionsbaustein S7-400 mit CP für TCP/IP Kommunikation IC-KP-B17-AIDA1 SingleFrame Protokoll UHF-SystemALLZIP1271 KB

Associated Products: IC-KP-B17-AIDA1

Accessory of

1,077.00  USD

In stock

Read/write head for IDENTControl, USA, Canada, Mexico, and Argentinafa
Read/Write head for IDENTControl, Europe, Middle East and Africafa
1,997.00  USD

In stock

Read/write head for IDENTControl, USA and Argentinafa
UHF read/write head for IDENTControl, Europefa
UHF read/write head for hazardous areas, for IDENTControl, Canada, USA, and Mexicofa
UHF read/write head for IDENTControl, Moroccofa
Read/Write head for IDENTControl, Asia and the Americas except Canada, United States and Mexicofa
UHF read/write head for IDENTControl, Chinafa
UHF read/write head for IDENTControl, Indiafa
UHF read/write head for IDENTControl, Singapore and Vietnamfa
UHF read/write head for IDENTControl, Russiafa
UHF read/write head for IDENTControl, Brazilfa
UHF read/write head for IDENTControl, Thailand and Hong Kongfa
UHF read/write head for IDENTControl, Malaysiafa
UHF read/write head for IDENTControl, Singapore and Vietnamfa
HF read/write head, ISO 15693, for IDENTControlfa
Accessories

35.00  USD

In stock

MSTB connector, lockablefa

81.00  USD

In stock

Connection cable MSTB to M12 connectorfa

101.00  USD

In stock

Connection cable MSTB to cable tailfa
Blind plug for IC-KP-B17-AIDA1fa
44.00  USD

In stock

Connecting cable, M12 to M12, PUR cable 4-pin, shieldedfa
Cable, PROFINET, PUR/PE, 4-wire, shieldedfa
Software for RFID identification systemsfa
Plug connector for RJ-45fa
Connecting cable RJ-45 to M12 D-codedfa
Connecting cable RJ-45 to RJ-45, PUR cable 4-pole, CAT5efa
Visit the RFID Hub

Visit our "RFID Hub"—this special website is a knowledge base for RFID. Get answers on frequently asked questions and learn about typical RFID applications …