Serviceline Industrial Sensors
Phone: 330-486-0001
Fax: 330-405-4710
Serviceline Explosion Protection
Phone: 330-486-0002
Fax: 330-963-5827

Control interface unit IC-KP2-1HB6-2V15B

IC-KP2-1HB6-2V15B
  • LED status indicator of bus communication and read/write head

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  IC-KP2-1HB6-2V15B

Product Description
Control interface unit IDENTControl Compact with interface for PROFIBUS DP
General specifications
Number of read/write headsmax. 1
UL File NumberE87056
Functional safety related parameters
MTTFd140 a
Mission Time (TM)10 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
LED BUSgreen: Slave is at state "Data Exchange"
red: Bus error
LED 1Status indicator for read/write head
green: command at read/write head active
yellow: approx. 1 second long, if command was successfully executed
LED CH1green: read head detected
red: Configuration error
LED PWR/ERRgreen: power on
red: Hardware fault
Rotary switchAddress setting 00 ... 7E, FF (hexadecimal)
BUS Address (high nibble): 0 ... 7, F
BUS Address (low nibble): 0 ... F
Electrical specifications
Rated operating voltage20 ... 30 V DC , PELV
Ripple≤ 10 % at 30 V DC
Current consumption≤ 4 A incl. read/write head
Power consumption2 W Without read/write head
Galvanic isolationbasic insulation acc. to DIN EN 50178, rated insulation voltage of 50 Veff
Interface 1
Interface typePROFIBUS
Physical RS-485
ProtocolPROFIBUS DP acc. to EN 50170
Transfer rate9.6; 19.2; 93.75; 187.5; 500; 1500 kBit/s
3; 6; 12 Mbit/s self-synchronizing
Interface 2
Interface typePROFIBUS
Physical RS-485
ProtocolPROFIBUS DP acc. to EN 50170
Transfer rate9.6; 19.2; 93.75; 187.5; 500; 1500 kBit/s
3; 6; 12 Mbit/s 38.4 kBit/s self-synchronizing
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61000-6-2
EN 61000-6-4
RoHS
Directive 2011/65/EU (RoHS)EN 50581
Standard conformity
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Climatic conditionsair humidity max. 96 %
Salt spray resistant to EN 60068-2-52
Shock and impact resistanceOscillation (Sine): 5 g, 10 - 1000 Hz to EN 60068-2-6
Shock (Half-sine): 30 g, 11 ms in accordance with EN 60068-2-27
Mechanical specifications
Degree of protectionIP67
Connectionread/write head: M12 plug connection, 4-pin, screened,
Power supply: M12 connector
Protective earth: M4 earthing screw
PROFIBUS: M12 connector, B-coded
Material
Housingpowder coated aluminum
Installationscrew fixing
Massapprox. 300 g

Documents: IC-KP2-1HB6-2V15B

ManualsLanguageFile TypeFile Size
Manual IC-KP2-1HB6-2V15BENGPDF1440 KB
Manual Read / Write Ranges and Passing Speeds RFIDENGPDF3640 KB
Handbuch IC-KP2-1HB6-2V15BGERPDF1452 KB
Handbuch Schreib- und Leseabstände und Vorbeifahrgeschwindigkeiten RFIDGERPDF3642 KB
Short instructions, safety information
Quick Start Guide IC-KP2-*ENGPDF2285 KB
Kurzanleitung IC-KP2-*GERPDF2341 KB

CAD+CAE: IC-KP2-1HB6-2V15B

CADFile TypeFile Size
3-D model in IGS format / 3-D-Modell im IGS-FormatIGS2493 KB
3-D model in STP format / 3-D-Modell im STP-FormatSTP1666 KB
CAD Portal / CAD PortalLINK---

Approvals+Certificates: IC-KP2-1HB6-2V15B

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of conformity / EU-KonformitätserklärungDOC-0687CPDF163 KB
Certificates
US CA ULE87056LINK---

Commissioning: IC-KP2-1HB6-2V15B

Commissioning filesLanguageFile TypeFile Size
Function block Step 7 Classic for the evaluation unit IC-KP2-1HBx with the RFID heads IQH1-...-V1 for complete reading and writing of the IQC21 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP2-1HBx mit den RFID-Köpfen IQH1-...-V1 zum vollständigen Lesen und Schreiben des IQC21 DatenträgersALLZIP2115 KB
Function block Step 7 Classic for the evaluation unit IC-KP2-1HBx with the RFID heads IQH1-...-V1 for complete reading and writing of the IQC22 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP2-1HBx mit den RFID-Köpfen IQH1-...-V1 zum vollständigen Lesen und Schreiben des IQC22 DatenträgersALLZIP2113 KB
Function block Step 7 Classic for the evaluation unit IC-KP2-1HBx with the RFID heads IQH1-...-V1 for complete reading and writing of the IQC24 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP2-1HBx mit den RFID-Köpfen IQH1-...-V1 zum vollständigen Lesen und Schreiben des IQC24 DatenträgersALLZIP2120 KB
Function block Step 7 Classic for the evaluation unit IC-KP2-1HBx with the RFID heads IQH1-...-V1 for complete reading and writing of the IQC33 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP2-1HBx mit den RFID-Köpfen IQH1-...-V1 zum vollständigen Lesen und Schreiben des IQC33 DatenträgersALLZIP2124 KB
Function block Step 7 Classic for the evaluation unit IC-KP2-1HBx with the RFID heads IQH1-...-V1 for complete reading and writing of the IQC35 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP2-1HBx mit den RFID-Köpfen IQH1-...-V1 zum vollständigen Lesen und Schreiben des IQC35 DatenträgersALLZIP2114 KB
Function block Step 7 Classic for the evaluation unit IC-KP2-1HBx with the RFID heads IQH1-...-V1 for reading and writing of the IQC37 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP2-1HBx mit den RFID-Köpfen IQH1-...-V1 zum Lesen und Schreiben des IQC37 DatenträgersALLZIP2121 KB
Function block TIA Portal (S7-1200/1500) for IC-KP2-1HB (Profinet + Profibus) with IPH-...-V1, IQH1-...-V1 or IUH-...-V1 RFID heads with single-frame protocol / Funktionsbaustein TIA Portal (S7-1200/1500) für IC-KP2-1HB (Profinet + Profibus) mit IPH-...-V1, IQH1-...-V1 oder IUH-...-V1 RFID-Köpfen mit Single-Frame ProtokollALLZIP23798 KB
Function block TIA Portal (S7-1200/1500) for the evaluation units IDENTControl IC-KP2-1HB (Profinet + Profibus) when using IUH-F190-V1-FR and IUH-F192-V1-FR RFID heads with multi-frame protocol. / Funktionsbaustein TIA Portal (S7-1200/1500) für die Auswerteeinheiten IDENTControl IC-KP2-1HB (Profinet + Profibus) bei der Verwendung von IUH-F190-V1-FR und IUH-F192-V1-FR RFID-Köpfen mit Multi-Frame Protokoll.ALLZIP17056 KB
Function block TIA Portal (S7-300/400) for the evaluation units IDENTControl IC-KP2-1HB (Profinet + Profibus) when using IPH-...-V1, IQH1-...-V1 or IUH-...-V1 RFID heads with single-frame protocol. / Funktionsbaustein TIA Portal (S7-300/400) für die Auswerteeinheiten IDENTControl IC-KP2-1HB (Profinet + Profibus) bei der Verwendung von IPH-...-V1, IQH1-...-V1 oder IUH-...-V1 RFID-Köpfen mit Single-Frame Protokoll.ALLZIP9719 KB
SIMATIC S7 sample project file for PROFIBUS with IC-KP2-1HB6 / SIMATIC S7 Beispielprojekt für die PROFIBUS-Anbindung mit IC-KP2-1HB6ALLZIP702 KB
Step 7 function block S7-300/400 for IC-KP2-1HB17 (Profinet) and IC-KP2-1HB6 (Profibus) MultiFrame protocol UHF-System / Step 7 Funktionsbaustein S7-300/400 für IC-KP2-1HB17 (Profinet) und IC-KP2-1HB6 (Profibus) MultiFrame Protokoll UHF-SystemALLZIP8208 KB

Software: IC-KP2-1HB6-2V15B

DriversRelease InfoFile TypeFile Size
GSD file IC-KP2-xHB6-... / GSD-Datei IC-KP2-xHB6-...06/2009ZIP6 KB

Associated Products: IC-KP2-1HB6-2V15B

Accessory of
UHF read/write head for hazardous areas, for IDENTControl, Canada, USA, and Mexicofa
Accessories
34.00  USD

In stock

Cordset M12 socket straight to M12 plug angled A-coded, 4-pin, PUR cable grey, shieldedfa
59.00  USD

In stock

Cordset M12 socket straight to M12 plug angled A-coded, 4-pin, PUR cable grey, shieldedfa
Bus cable PROFIBUS, M12 to M12, PUR cablefa
Bus cable PROFIBUS, M12 to M12, PUR cablefa
Mounting aid for DIN railfa
45.00  USD

In stock

Cordset M12 socket straight to M12 plug angled A-coded, 4-pin, PUR cable grey, shieldedfa
32.00  USD

In stock

Female cordset single-ended M12 straight A-coded, 4-pin, PUR cable grey, shieldedfa
Y connection cable for PROFIBUSfa
Terminal cable for PROFIBUS with terminal resistorfa

Function: IC-KP2-1HB6-2V15B

The RFID identification system IDENTControl Compact from Pepperl+Fuchs offers a vast number of benefits compared to other systems, thanks to its innovative design. The control interfaces IDENTControl and IDENTControl Compact make up the core of the system.

With its integrated interfaces to all commercially available fieldbus systems such as PROFIBUS, PROFINET, Ethernet, EtherCAT, CC-Link, serial connections (RS 232 or RS 485) and numerous connection options for read/write heads available for frequency ranges LF, HF and UHF, the IDENTControl Compact control interface can be easily and flexibly adapted to your requirements.

LEDs on the front of the housing indicate bus communication, connected read/write heads and active read/write commands. Reliability of the application is further increased by using trigger sensors.

The system is equally suited for use in control cabinets and field use in IP67. The interface to the higher-level fieldbus is integrated in the housing, and all connections are designed such that they are pluggable. This enables simple installation and quick, problem-free replacement in case of device failure. The consistent EMC design, with metal housing, grounding and shielded wires, offers a high degree of reliability.

Visit the RFID Hub

Visit our "RFID Hub"—this special website is a knowledge base for RFID. Get answers on frequently asked questions and learn about typical RFID applications …