Supply | ||
---|---|---|
Rated voltage | 19.2 ... 35 V DC | |
Rated current | 150 ... 100 mA | |
Power dissipation | 3 W | |
Ethernet Interface | ||
Intrinsically safe port | 10 BASE-T/100 BASE-TX | |
Non-intrinsically safe port | 10 BASE-T/100 BASE-TX | |
Connection type | 2 x RJ-45 , IEC 60603-7 | |
Connector pinout | socket ; TIA/EIA-568-B | |
Transfer rate | 10/100 Mbit/s , Auto-Negotiation | |
Operating mode | Half/Full Duplex | |
Cable type | CAT5e S/FTP AWG 24, Installation cable, L/R ratio max. 10 µH/Ω of all strand combinations | |
I.S. cable length | typ. 100 m/20 °C | |
Total cable length | typ. 200 m/20 °C | |
Number of isolators | max. 2 in series connection | |
Indicators/operating means | ||
LED PWR | green: Power on | |
LED ACT | yellow: communication active | |
LED 10/100 | yellow ON: Transfer rate 100 MBit/s , OFF: 10 MBit/s | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 | |
Standard conformity | ||
Galvanic isolation | EN 50020 | |
Degree of protection | IEC 60529 | |
Climatic conditions | DIN IEC 721 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Ethernet | IEEE 802.3 , IEEE 802.3u | |
Ambient conditions | ||
Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | ≤ 95 % non-condensing | |
Shock resistance | 15 g 11 ms | |
Vibration resistance | 1 g 10 ... 150 Hz | |
Pollution degree | max. 2, according to IEC 60664 | |
Mechanical specifications | ||
Connection type | Terminals | |
Core cross-section | up to 2.5 mm2 | |
Housing material | Polyamide PA 66 | |
Degree of protection | IP20 according to EN 60529 | |
Mass | 195 g | |
Mounting | DIN rail mounting | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | PTB 07 ATEX 2025 X | |
Marking | ![]() ![]() ![]() ![]() ![]() |
|
Supply | ||
Maximum safe voltage | 253 V AC | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 | |
International approvals | ||
CSA approval | CSA 15.70016295 | |
Control drawing | 116-B032 | |
Approved for | Class I, Zone 2, AEx/Ex nA [ia Ga] IIB T4 Gc Class I, Zone 2, AEx/Ex nA [ia Da IIIC] IIB T4 Gc | |
IECEx approval | IECEx PTB 09.0053X | |
Approved for | [Ex ia Ga] IIB [Ex ia Da] IIIC Ex nA [ia Ga] IIB T4 Gc Ex nA [ia IIIC Da] IIB T4 Gc [Ex ia Ma] I |
|
Certificates and approvals | ||
Patents | This product may be covered by the following patent: US7,687,791 |
Manuals | Language | File Type | File Size |
---|---|---|---|
Manual | ENG | 1759 KB | |
Handbuch | GER | 1573 KB | |
Instruction manuals | |||
Инструкции | BUL | 134 KB | |
Návod k poużití | CZE | 0 KB | |
Instruktions manual | DAN | 0 KB | |
Instruction manual | ENG | 123 KB | |
Kasutusjuhend | EST | 125 KB | |
Käyttöohje | FIN | 186 KB | |
Manuel d'instructions | FRA | 68 KB | |
Betriebsanleitung | GER | 125 KB | |
Οδηγίες χρήσης | GRE | 198 KB | |
Handleiding | HOL | 0 KB | |
Instruction manual / Betriebsanleitung | HRV | 188 KB | |
Használati útmutató | HUN | 190 KB | |
Manuale di istruzioni | ITA | 125 KB | |
Lietošanas pamācība | LAV | 0 KB | |
Instrukciju vadovas | LIT | 0 KB | |
Instrukcja obsługi | POL | 0 KB | |
Manual de instruções | POR | 190 KB | |
Manual de utilizare | RON | 189 KB | |
Návod na poużitie | SLK | 191 KB | |
Navodila za uporabo | SLV | 2 KB | |
Manual de instrucciones | SPA | 126 KB | |
Manual | SWE | 0 KB |
CAD | File Type | File Size | |
---|---|---|---|
3-D model in IGS format / 3-D-Modell im IGS-Format | IGS | 6274 KB | |
3-D model in STP format / 3-D-Modell im STP-Format | STP | 2223 KB | |
CAD Portal / CAD Portal | LINK | --- | |
Dimension drawing 2-D (DXF) / Abmessungszeichnung 2-D (DXF) | ZIP | 787 KB |
Statements of compliance | Certificate No. | File Type | File Size |
---|---|---|---|
EU-Declaration of conformity / EU-Konformitätserklärung | DOC-1092B | 141 KB | |
Certificates | |||
Canada, USA CSA Certificate of Compliance | 14.70016295 | 89 KB | |
Europe PTB ATEX Category 3 ATEX Category (1) GD | PTB 07 ATEX 2025X | 2202 KB | |
PTB IECEx Certificate of Conformity | IECEx PTB 09.0053X | LINK | --- |
Russia Belarus Kazakhstan EAC EAC TP TC 012/2011 | EAEC RU C-DE.EX01.B.00102/19 | 9815 KB | |
Control drawings | |||
control drawing CSA / Steuerzeichen CSA | 94 KB |
The Ethernet Isolator is an intrinsically safe isolated barrier. It enables cost effective and simple installation in hazardous areas up to Zone 0. It supports high-speed Ethernet and can be mounted in Zone 2.
At each end of the trunk, an Ethernet Isolator is installed. In combination, they provide the intrinsically safe energy limitation. The Ethernet Isolator offers a wire-based alternative to wireless LAN, fiber optic solutions, and Ex e installations.
In safe area applications, a single Ethernet Isolator can be used for galvanic isolation. The Ethernet Isolator is compatible with all IEEE standards. It provides high noise immunity and low heat dissipation in a compact housing.