Fieldbus Power Hub, Compact Power Supply Module HCD2-FBPS-1.500

HCD2-FBPS-1.500
  • Output: 28 ... 30 V/500 mA
  • High-power trunk for high device count and long cable lengths
  • With galvanic isolation
  • Installation in Zone 2/Class I, Div. 2
  • For FOUNDATION Fieldbus H1 and PROFIBUS PA
  • Highest efficiency, lowest heat dissipation for highest packing density
  • Hot swappable in redundant configuration
  • Module exchange without tools during operation
 Please contact the Serviceline for exact delivery estimation
492.00 USDUnit Price 

Quantity

Free Shipping

Purchase on Account

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH, also apply to Pepperl+Fuchs AG.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  HCD2-FBPS-1.500

General specifications
Design / MountingMotherboard based
Supply
Rated voltage19.2 ... 35 V DC
Power dissipationtyp. 1.6 W
Fieldbus interface
Rated voltage28 ... 29.5 V
Rated current500 ... 10 mA
Short-circuit current550 mA
Terminating resistormotherboard specific
Indicators/operating means
LED ERRred flashing: short-circuit or undervoltage at output
LED PWRgreen if Uout > 28 V
Galvanic isolation
Fieldbus segment/Supplyfunctional insulation acc. to IEC 62103, rated insulation voltage 250 V AC
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
Standard conformity
Electromagnetic compatibilityNE 21:2011
Degree of protectionIEC 60529
Fieldbus standardIEC 61158-2
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
Ambient conditions
Ambient temperature-40 ... 70 °C (-40 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity< 95 % non-condensing
Shock resistance15 g 11 ms
Vibration resistance1 g , 10 ... 150 Hz
Pollution degreemax. 2, according to IEC 60664
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
Mechanical specifications
Connection typemotherboard specific
Core cross-sectionmotherboard specific
Housing materialPolycarbonate
Housing width12.5 mm
Housing height106 mm
Housing depth128 mm
Degree of protectionIP20
Massapprox. 150 g
Mountingmotherboard mounting
Data for application in connection with hazardous areas
Outputs
Voltage30 V
CertificateTÜV 10 ATEX 555761X
MarkingEx-Hexagon II 3G Ex nA IIC T4 Gc
Directive conformity
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
FM approval
FM certificateFM 19 US 0015 X and FM 19 CA 0011 X
FM markingAEx/Ex ec IIC T4
IECEx approval
IECEx certificateIECEx TUN 13.0037X
IECEx markingEx ec IIC T4 Gc
Certificates and approvals
Marine approvalDNV A-14038
General information
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Documents: HCD2-FBPS-1.500

Instruction manualsLanguageFile TypeFile Size
ИнструкцииBULPDF208 KB
Návod k poużitíCZEPDF202 KB
Instruktions manualDANPDF0 KB
Instruction manualENGPDF76 KB
KasutusjuhendESTPDF195 KB
KäyttöohjeFINPDF0 KB
Manuel d'instructionsFRAPDF141 KB
BetriebsanleitungGERPDF78 KB
Οδηγίες χρήσηςGREPDF0 KB
HandleidingHOLPDF199 KB
Instruction manual / BetriebsanleitungHRVPDF200 KB
Használati útmutatóHUNPDF201 KB
Manuale di istruzioniITAPDF138 KB
Lietošanas pamācībaLAVPDF200 KB
Instrukciju vadovasLITPDF202 KB
Instrukcja obsługiPOLPDF203 KB
Manual de instruçõesPORPDF202 KB
Manual de utilizareRONPDF202 KB
Návod na poużitieSLKPDF0 KB
Navodila za uporaboSLVPDF200 KB
Manual de instruccionesSPAPDF138 KB
ManualSWEPDF198 KB
Product information
Conformity matrix for R2-SP-IC* and F2-SP-IC* with motherboards: MBHC*, FBTA-228-BPFB-R-8R and power supply modules: HCD2-FBPS-*ENGPDF143 KB
Guideline for Using Fieldbus Equipment in Zone 2ENGPDF883 KB

Approvals+Certificates: HCD2-FBPS-1.500

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of conformity / EU-KonformitätserklärungDOC-2674APDF85 KB
Certificates
Canada FMFM 19 CA 0011XPDF356 KB
DNV GL MarineTAA0000272PDF78 KB
EAC Lenpromexpertiza (LPE) EAC TP TC 012/2011EAEC RU C-DE.AA71.B.00037/19PDF2835 KB
Europe TUV Nord ATEX Category 3 GTÜV 10 ATEX 555761XPDF2931 KB
India PESO (India) CCOEA/P/HQ/KA/104/5527 (P404204)PDF808 KB
Russia Belarus Kazakhstan EAC EMC EAC TP TC 012/2011EAEC N RU D-DE.EA11.B.00318PDF2892 KB
TUV NordIECEx TUN 13.0037XLINK---
USA FMFM 19 US 0015XPDF213 KB
Worldwide Fieldbus FoundationPS066300PDF31 KB

Associated Products: HCD2-FBPS-1.500

Matching system components
8 segments, redundant, individual modules per segment, Customized for Invensys, FBM228, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1pa
4 segments, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1pa
4 segments, simplex, individual modules per segment, For PROFIBUS PA, For gateway and power supply modules, High-power trunk: Live work on devices in any hazardous area, Optional advanced diagnosticspa
4 segments, individual modules per segment, Customizable cable connections to any PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus and PROFIBUS PApa
4 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1pa
4 segments, redundant, individual modules per segment, Customizable cable connections to any PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus and PROFIBUS PApa
4 segments, redundant, individual modules per segment, Customized for Yokogawa, ALF 111, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1pa
4 segments, individual modules per segment, Customized for Yokogawa, ALF 111, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1pa
8 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1pa
8 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1pa
8 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, redundant terminals, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1 and PROFIBUS PApa
8 segments, redundant, individual modules per segment, Customized for Yokogawa, ALF 111, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1pa

Function: HCD2-FBPS-1.500

This Power Supply Module is a system component for the FieldConnex® Power Hub and can be plugged into the motherboard. It adapts current and voltage for the supply of fieldbus segments and field devices.

This power supply features the highest output power and allows for maximum cable lengths and highest number of devices in hazardous areas with the High-Power Trunk concept.

Reliability of communication is enhanced through galvanic isolation between segment and bulk power supply. Two LEDs indicate power and status. In redundant configuration two modules are connected in parallel via simple circuits ensuring seamless operation.

From decisions to planning, installation, and commissioning up to operation and maintenance: Discover how to make the most out of your fieldbus infrastructure …

The Quick Select Product Guide for interface technology, FieldConnex®, and remote I/O connection technologies will help you select the right technology and systems when designing plants.