General specifications | ||
---|---|---|
Signal type | Analog input | |
Operation time | MTBF: 536 a acc. to SN 29500 stationary continuous operating, average ambient temperature 40 °C (104 °F) |
|
Supply | ||
Connection | Power Bus or terminals 1-, 2+ | |
Rated voltage | 16.8 ... 31.2 V DC | |
Power dissipation | 0.6 W | |
Power consumption | 0.7 W | |
Input | ||
Connection side | field side | |
Transmission range | linearity range: -1 ... 110 % | |
Input I | ||
Connection | terminals 5+, 6- | |
Input signal | 0/4 ... 20 mA , max. 50 mA | |
Input resistance | ≤ 25 Ω | |
Input II | ||
Connection | terminals 7+, 8- | |
Input signal | 0/2 ... 10 V , max. 30 V | |
Input resistance | > 100 kΩ | |
Output | ||
Connection side | control side | |
Connection | terminals 3-, 4+ | |
Analog voltage output | 0/2 ... 10 V , load ≥ 2 kΩ | |
Analog current output | 0/4 ... 20 mA, load ≤ 600 Ω | |
Ripple | ≤ 10 mV eff | |
Transfer characteristics | ||
Accuracy | max. 0.1 % of full-scale value | |
Influence of ambient temperature | < 100 ppm/K of full-scale value | |
Frequency range | 0 ... 10 Hz , 0 ... 100 Hz , 0 ... 5 kHz | |
Settling time | 70 ms , 7 ms , 150 µs | |
Galvanic isolation | ||
Output/power supply | safe electrical isolation by reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff test voltage 3 kV, 50 Hz, 1 min | |
Input/Other circuits | safe electrical isolation by reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff test voltage 3 kV, 50 Hz, 1 min | |
Indicators/settings | ||
Control elements | DIP switch | |
Configuration | via DIP switches | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Protection against electrical shock | EN 61010-1:2010 | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Core cross section | 0.5 ... 2.5 mm2 (20 ... 14 AWG) | |
Mass | approx. 70 g | |
Dimensions | 6.2 x 97 x 107 mm (0.24 x 3.82 x 4.21 inch) (W x H x D) , housing type S1 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
Certificate | DEMKO 16 ATEX 1750X | |
Marking | ![]() |
|
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-15:2010 | |
International approvals | ||
UL approval | E106378 | |
IECEx approval | ||
IECEx certificate | IECEx UL 16.0116X | |
IECEx marking | Ex nA IIC T4 Gc | |
General information | ||
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
System | Classcode |
---|---|
ECLASS 11.0 | 27210119 |
ECLASS 10.0.1 | 27210119 |
ECLASS 9.0 | 27210119 |
ECLASS 8.0 | 27210119 |
ECLASS 5.1 | 27210119 |
ETIM 8.0 | EC001485 |
ETIM 7.0 | EC001485 |
ETIM 6.0 | EC001485 |
ETIM 5.0 | EC001485 |
UNSPSC 12.1 | 32101514 |
Manuals | Language | File Type | File Size |
---|---|---|---|
Manual | ENG | 2762 KB | |
Handbuch | GER | 2771 KB | |
Instruction manuals | |||
Návod k poużití | CZE | 132 KB | |
Instruktions manual | DAN | 0 KB | |
Instruction manual | ENG | 136 KB | |
Kasutusjuhend | EST | 127 KB | |
Käyttöohje | FIN | 127 KB | |
Manuel d'instructions | FRA | 138 KB | |
Betriebsanleitung | GER | 137 KB | |
Οδηγίες χρήσης | GRE | 141 KB | |
Handleiding | HOL | 0 KB | |
Instruction manual / Betriebsanleitung | HRV | 130 KB | |
Manuale di istruzioni | ITA | 135 KB | |
Lietošanas pamācība | LAV | 131 KB | |
Instrukciju vadovas | LIT | 0 KB | |
Instrukcja obsługi | POL | 134 KB | |
Manual de instruções | POR | 132 KB | |
Manual de utilizare | RON | 0 KB | |
Návod na poużitie | SLK | 131 KB | |
Navodila za uporabo | SLV | 130 KB | |
Manual de instrucciones | SPA | 137 KB | |
Manual | SWE | 129 KB | |
Product information | |||
Product Overview SC-System | ENG | 456 KB | |
Product Overview SC-System | GER | 488 KB | |
Tender texts | |||
Tender text in GAEB format | ENG | D81 | 6 KB |
Tender text in TXT format | ENG | TXT | 4 KB |
Ausschreibungstext im GAEB-Format | GER | D81 | 6 KB |
Ausschreibungstext im TXT-Format | GER | TXT | 4 KB |
CAD | File Type | File Size | |
---|---|---|---|
3-D model / 3-D-Modell | STP | 4814 KB | |
CAD Portal / CAD Portal | LINK | --- | |
EPLAN | |||
EPLAN Data Portal / EPLAN Data Portal | LINK | --- | |
EPLAN macro P+F.S1SD-1AI-1U.1 / EPLAN-Makro P+F.S1SD-1AI-1U.1 | EDZ | 91 KB | |
EPLAN macros SC-System devices (EDZ) / EPLAN-Makros SC-System-Geräte (EDZ) | ZIP | 4082 KB |
Statements of compliance | Certificate No. | File Type | File Size |
---|---|---|---|
EU-Declaration of conformity / EU-Konformitätserklärung | DOC-0534D | 468 KB | |
Certificates | |||
Belarus Pattern Approval | Nr. 11703 | 6929 KB | |
Canada UL cUL | E106378 cUL (QUZW7) | LINK | --- |
Europe DEMKO ATEX Category 3 G | DEMKO 16 ATEX 1750X | 1876 KB | |
UL Non-Sparking nA IECEx Certificate of Conformity | IECEx UL 16.0116X | LINK | --- |
USA UL | E106378 UL (QUZW) | LINK | --- |
Matching System Components | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|
This signal conditioner provides the galvanic isolation between field circuits and control circuits.
The device has an input for the following signals:
- 0/4 mA ... 20 mA signal
- 0/2 V ... 10 V signal
The device provides the following standard signals at the output:
- 0/4 mA ... 20 mA signal
- 0/2 V ... 10 V signal
The device is easily configured by the use of DIP switches.
The device can be powered via terminals or Power Bus.