Distance sensor VDM28-15-L-IO/73c/110/122

VDM28-15-L-IO/73c/110/122
  • Distance measurement using object
  • Measuring method PRT (Pulse Ranging Technology)
  • IO-link interface for service and process data
  • Analog output 0/4 mA ... 20 mA
  • Accurate, clear, and reproducible measuring results
  • Minimal black-white difference
 in stock
492.00 USDUnit Price 

Quantity

Free Shipping

Purchase on Account

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH, also apply to Pepperl+Fuchs AG.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  VDM28-15-L-IO/73c/110/122

Product Description
Universal distance sensor, measurement to object, IO-Link interface, measuring method PRT, 15 m detection range, red laser light, laser class 2, push-pull output, analog output, M12 plug
General specifications
Measurement range0.2 ... 15 m
Light sourcelaser diode
typ. service life 85,000 h at Ta = +25 °C
Light typemodulated visible red light
Laser nominal ratings
Laser class2
Wave length660 nm
Measuring methodPulse Ranging Technology (PRT)
Diameter of the light spot< 15 mm at a distance of 15 m at 20 °C
Functional safety related parameters
MTTFd200 a
Mission Time (TM)10 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
Function indicator2 LEDs yellow for switching state
Control elements5-step rotary switch for operating modes selection (threshold setting and operating modes)
Control elementsSwitch for setting the threshold values
Electrical specifications
Operating voltage10 ... 30 V DC / when operating in IO-Link mode: 18 ... 30 V
Interface
Interface typeIO-Link
ProtocolIO-Link V1.0
Process data witdh16 bit
Output
Signal outputPush-pull output, short-circuit protected, reverse polarity protected
Compliance with standards and directives
Standard conformity
Product standardEN 60947-5-2
Laser classIEC 60825-1:2007 Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007
Approvals and certificates
EAC conformityTR CU 020/2011
Mechanical specifications
Housing width25.8 mm
Housing height88 mm
Housing depth54.6 mm
Degree of protectionIP65
Connection4-pin, M12 x 1 connector
Material
HousingPlastic ABS
Optical facePlastic pane

Documents: VDM28-15-L-IO/73c/110/122

Instruction leafletsLanguageFile TypeFile Size
Instruction leaflet / Beipackzettel ALLPDF872 KB
Product information
A Distance Ahead - Messende optoelektronische SensorenGERPDF3050 KB

CAD+CAE: VDM28-15-L-IO/73c/110/122

CADFile TypeFile Size
3-D model in IGS format / 3-D-Modell im IGS-FormatIGS2429 KB
3-D model in STP format / 3-D-Modell im STP-FormatSTP2222 KB
CAD Portal / CAD PortalLINK---

Approvals+Certificates: VDM28-15-L-IO/73c/110/122

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of Conformity / EU-KonformitätserklärungDOC-0845BPDF184 KB
Certificates
EU Pepperl+FuchsPF08CERT1244PDF503 KB
Pepperl+Fuchs IO-Link Manufacturer DeclarationPF 13 CERT 2631PDF275 KB
US CA UL General PurposeE87056LINK---

Software: VDM28-15-L-IO/73c/110/122

Software ToolsRelease InfoFile TypeFile Size
Device DTM for VDM28 IO-Link sensors / Geräte-DTM für VDM28 IO-Link Sensorenv1.0.3.2ZIP4937 KB
IODD for VDM28-8-L / -15-L / IODD für VDM28-8-L / -15-LV1.13.000 / 2017-12-15ZIP154 KB

Associated Products: VDM28-15-L-IO/73c/110/122

Accessories
Universal DTM host platform, For all DTMs of Pepperl+Fuchs, Approved FDT/DTM technology, Free of charge, Internet download possiblepa
IODD for communication with VDM28-IO-Link sensorsfa
Device DTM for communication with VDM28-IO-Link sensorsfa
IO-Link master, supply via USB port or separate power supply, LED indicators, M12 plug for sensor connectionfa
Communication DTM for use of IO-Link-Masterfa
Software for the integration of IODDs in a frame application (e. g. PACTware)fa
Mounting aid for round steel ø 12 mm or sheet 1.5 mm ... 3 mmfa
Mounting aid for round steel ø 12 mm or sheet 1.5 mm ... 3 mmfa
16.00  USD

In stock

Mounting bracket fa
27.00  USD

In stock

Mounting bracket fa
Metal enclosure for inserting protective panes or aperturesfa
Mounting and fine adjustment device for sensors from the 28 seriesfa
16.00  USD

In stock

Mounting bracket for rear wall mountingfa
60.00  USD

In stock

Weld slag cover modelfa
dove tail mounting clampfa
dove tail mounting clampfa

Function: VDM28-15-L-IO/73c/110/122

The VDM28 distance measurement device employs Pulse Ranging Technology (PRT). It has a repeat accuracy of 5 mm with an operating range of 0.2 ... 15 m and an absolute accuracy of 25 mm.

The compact housing of the Series 28 photoelectric sensors, with dimensions of 88 mm (height), 26 mm (width) and 54 mm (depth), make it the smallest device available in its class.

Discover the SmartRunner light section sensors equipped with a unique combination of light section technology and a 2-D vision sensor with integrated LEDs …