Quantity
Free Shipping
Purchase on Account
Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Download the complete datasheet as a PDF:
Product Description |
---|
UHF read/write station with IO-Link, USA and Canada |
General specifications | ||
---|---|---|
Operating frequency | 902 … 928 MHz: USA, Canada Transmission licenses for other countries on request |
|
Emitted power | 3 … 150 mW EIRP adjustable | |
Operating distance | typ. 1 m | |
Functional safety related parameters | ||
MTTFd | 254 a | |
Indicators/operating means | ||
LED green/red | Solid green: Ready for operation, no IO-Link communication Flashing green (1 Hz): IO-Link operation |
|
LED yellow | Read/write operation successful | |
LED blue | Transmission mode | |
Electrical specifications | ||
Operating voltage | 18 ... 30 V DC (IO-Link) | |
Current consumption | ≤ 90 mA ( at 24 V DC ) | |
Interface | ||
Interface type | IO-Link | |
IO-Link revision | 1.1 | |
Device profile | Identification and Diagnosis - I&D | |
Process data | Input 32 Byte Output 32 Byte |
|
Vendor ID | 1 (0x0001) | |
Device ID | 4194818 (0x400202) | |
Data transfer rate | COM3 (230.4 kbits/s) | |
Min. cycle time | 4 ms | |
SIO mode support | no | |
Compatible master port type | Class A Class B |
|
Standard conformity | ||
Electromagnetic compatibility | EN 301489-1 EN 301489-3 |
|
Degree of protection | EN 60529 | |
Communication interface | IEC 61131-9 / IO-Link V1.1.3 | |
RFID | ISO/IEC 18000-63 | |
Approvals and certificates | ||
FCC approval | This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. |
|
IC approval | This device complies with Industry Canada licence-exempt RSS standard(s) and with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. |
|
Radio approval | USA: Contains FCC IREIURF191 Canada: Contains 7037A-IURF191 |
|
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) (Operation with nontransmission periods) -25 ... 60 °C (-13 ... 140 °F) (Continuous transmission mode) |
|
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Housing length | 165 mm | |
Housing width | 165 mm | |
Housing height | 47 mm | |
Degree of protection | IP67 | |
Connection | connector M12 x 1 | |
Material | ||
Housing | PA 6.6 | |
Base | Aluminum | |
Mass | 700 g |
System | Classcode |
---|---|
ECLASS 11.0 | 27280401 |
ECLASS 10.0.1 | 27280401 |
ECLASS 9.0 | 27280401 |
ECLASS 8.0 | 27280401 |
ECLASS 5.1 | 27280401 |
ETIM 8.0 | EC002998 |
ETIM 7.0 | EC002998 |
ETIM 6.0 | EC002998 |
ETIM 5.0 | EC002998 |
UNSPSC 12.1 | 43211710 |
The read/write station operates in the UHF frequency range and is optimized for use in industrial applications involving shorter distances. The device reads and writes passive tags acc. to EPC Generation 2 ( ISO/IEC 18000-63). The read/write station is compliant with the relevant transmission regulations.
The read/write station can be used in the USA and Canada.
Wide range of options supported for filtering data. The read/write station has an IO-Link interface and is connected via a M12 connector. The user can monitor the status of the read/write station using the integrated LEDs.
The read/write station has a typical detection range of around 1 meter; this range is determined by the tag used and can be adjusted by configuring the transmission power. Other influencing factors include the setup and installation of the specific application and the surrounding materials, particularly metal. The read and write distances for the relevant tag, which are detailed separately, have been established in a test laboratory under ideal conditions. For the actual read and write distances under real conditions, the combination of read/write station and tag must be tested in the desired application.
Literature | Language | File Type | File Size |
---|---|---|---|
Application Report - RFID Systems in Industrial Metal Stamping | ENG | 1773 KB |
Manuals | Language | File Type | File Size |
---|---|---|---|
Manual IUT-F191-IO-V1-FR* | ENG | 4808 KB | |
Parameter Information | |||
IO-Link Parameter Datasheet IUT-F191-IO-V1-FR2-02 / IO-Link-Parameter-Datenblatt IUT-F191-IO-V1-FR2-02 | ALL | 522 KB |
CAD | Language | File Type | File Size |
---|---|---|---|
3-D model / 3-D-Modell | ALL | STP | 1114 KB |
Certificates | Certificate No. | Language | File Type | File Size |
---|---|---|---|---|
Canada Radio Approval | 7037A-IURF191 | ALL | 1236 KB | |
IO-Link Manufacturer Declaration | CERT-6856 | ALL | 367 KB | |
USA FCC Approval | IREIURF191 | ALL | 187 KB | |
Declaration of Conformity | ||||
FCC Document of Conformity / FCC Konformitätserklärung | DOC-7063 | ALL | 281 KB |
Device Description Files/Drivers | Release Info | File Type | File Size |
---|---|---|---|
IODD for IUT-F191-IO-V1-FR2-02 / IODD für IUT-F191-IO-V1-FR2-02 | V1.01.000 / 2023-02-17 | ZIP | 169 KB |
Software Tools | |||
IO-Link Offline Parameterization Tool / IO-Link Offline-Parametriertool | V1.00.006 / 2022-07-10 | ZIP | 96138 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
Register for an introduction to RFID technology training session with our Product Manager. Sessions are one-on-one and last around an hour. All skill levels are welcome.