| General specifications |
| Switching element function | AC NC |
| Rated operating distance | 10 mm |
| Installation | flush |
| Output polarity | AC |
| Assured operating distance | 0 ... 8.1 mm |
| Reduction factor rAl | 0.33 |
| Reduction factor rCu | 0.28 |
| Reduction factor r304 | 0.81 |
| Nominal ratings |
| Operating voltage | 20 ... 253 V |
| Switching frequency | 0 ... 20 Hz |
| Hysteresis | typ. 5 % |
| Reverse polarity protection | reverse polarity tolerant |
| Voltage drop | < 5 V (IL > 50 mA); < 8 V (IL < 50 mA) |
Momentary current (20 ms, 0.1 Hz) | 0 ... 1600 mA |
| Operating current | 5 ... 200 mA |
| Off-state current | 0 ... 1.7 mA |
| Operating voltage display | LED, green |
| Switching state indication | LED, yellow |
| Approvals and certificates |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
| Connection type | Connector 7/8"-16 UN , 3-pin |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 30 mm |
| Protection degree | IP67 |
| Note | 1) In the temperature range below 0 °C, permissible operating voltage Ub 80...253 V Safety fuse ≤ 0.3 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. |