Technical Data: NBB10-30GM50-E3-M
| General specifications |
| Switching element function | PNP NC |
| Rated operating distance | 10 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 8.1 mm |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 30 mm x 30 mm x 1 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.4 |
| Nominal ratings |
| Installation conditions | |
| A | 0 mm |
| B | 10 mm |
| C | 16 mm |
| F | 37 mm |
| Operating voltage | 10 ... 65 V |
| Switching frequency | 0 ... 300 Hz |
| Hysteresis | 0.05 ... 2.2 mm |
| Reverse polarity protection | yes |
| Short-circuit protection | yes |
| Overload resistance | yes |
| Wire breakage protection | yes |
| Inductive overvoltage protection | yes |
| Surge suppression | yes |
| Ripple | 10 % |
| Voltage drop | ≤ 2.5 V |
| Repeat accuracy | 0.3 mm |
| Operating current | 0 ... 300 mA |
| Off-state current | ≤ 0.01 mA |
| No-load supply current | ≤ 10 mA |
| Switching state indication | LED, yellow |
| Functional safety related parameters |
| MTTFd | 1190 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
| e1 Type approval | 2006/28/EG |
| Ambient conditions |
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
| Connection type | cable PUR , 2 m |
| Core cross-section | 0.75 mm2 |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 30 mm |
| Protection degree | IP68 |
| Mass | 192 g |
Documents: NBB10-30GM50-E3-M
CAD+CAE: NBB10-30GM50-E3-M
Approvals+Certificates: NBB10-30GM50-E3-M
Associated Products: NBB10-30GM50-E3-M
| Accessories | Name |
| BF 30 | Mounting flange |
| EXG-30 | Mounting aid |