| General specifications |
| Switching element function | AC/DC binary NO |
| Rated operating distance | 3 mm |
| Installation | flush mountable |
| Output polarity | AC/DC |
| Assured operating distance | 0 ... 2.43 mm |
| Reduction factor rAl | 0.45 |
| Reduction factor rCu | 0.38 |
| Reduction factor r304 | 1 |
| Reduction factor rSt37 | 1.04 |
| Nominal ratings |
| Operating voltage | 20 ... 253 V AC/DC |
| Switching frequency | 25 Hz |
| Hysteresis | typ. 3 % |
| Reverse polarity protection | yes |
| Short-circuit protection | yes |
| Voltage drop | ≤ 8 V |
| Operating current | 4 ... 400 mA |
| Off-state current | ≤ 1.7 mA |
| Operating voltage display | LED, green |
| Switching state indication | LED, yellow |
| Functional safety related parameters |
| MTTFd | 529 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
| Protection class | II |
| Rated insulation voltage | 253 V |
| Design-impulse-voltage withstand | 4 kV |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
| Connection type | cable PVC , 5 m |
| Core cross-section | 0.5 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Protection degree | IP67 |