| General specifications |
| Switching element function | DC NC |
| Rated operating distance | 8 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.1 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.4 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.5 |
| Nominal ratings |
| Operating voltage | 3.5 ... 30 V |
| Switching frequency | 0 ... 1000 Hz |
| Reverse polarity protection | reverse polarity-conductive |
| Short-circuit protection | pulsing |
| Voltage drop | ≤ 3.5 V |
| Temperature drift | ± 15% |
| Operating current | 2 ... 100 mA |
| Off-state current | typ. 0.8 mA |
| Switching state indication | LED, yellow |
| Functional safety related parameters |
| MTTFd | 1530 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
| Ambient conditions |
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Mechanical specifications |
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.34 mm2 |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 18 mm |
| Protection degree | IP67 |