| General specifications |
| Switching element function | DC NO |
| Rated operating distance | 5 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 4.05 mm |
| Actuating element | Ferrous targets |
| Reduction factor rAl | 0 |
| Reduction factor rCu | 0 |
| Reduction factor r304 | 0.75 |
| Reduction factor rSt37 | 1 |
| Reduction factor rBrass | 0 |
| Nominal ratings |
| Operating voltage | 6 ... 30 V DC |
| Switching frequency | 15 Hz |
| Hysteresis | 3 ... 15 typ. 5 % |
| Reverse polarity protection | yes |
| Short-circuit protection | no |
| Voltage drop | ≤ 5.5 V DC |
| Operating current | 2 ... 100 mA |
| Off-state current | ≤ 1 mA |
| Indicators/operating means |
| Operating display | 4-way LED Yellow: output |
| Standard conformity |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 |
| Approvals and certificates |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
| Ambient conditions |
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) |
| Mechanical specifications |
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | Stainless steel 1.4305 / AISI 303 |
| Housing diameter | 18 mm |
| Protection degree | IP67 / IP68 / IP69K - cordset dependent according to cable specification |