| Product Description | ||
| Single head system | ||
| General specifications | ||
| Sensing range | 30 ... 500 mm | |
| Adjustment range | 50 ... 500 mm | |
| Unusable area | 0 ... 30 mm | |
| Standard target plate | 100 mm x 100 mm | |
| Transducer frequency | approx. 380 kHz | |
| Response delay | 21 ms minimum 63 ms factory setting |
|
| Indicators/operating means | ||
| LED green | solid: Power-on flashing: Standby mode or program function object detected |
|
| LED yellow 1 | solid: object in evaluation range flashing: program function |
|
| LED yellow 2 | solid: object in detection range flashing: program function |
|
| LED red | solid: temperature/program plug not connected flashing: fault or program function object not detected |
|
| Temperature/TEACH-IN connector | Temperature compensation , Evaluation range programming , output function setting | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC , ripple 10 %SS | |
| Power consumption | ≤ 900 mW | |
| Interface | ||
| Interface type | RS 232, 9600 Bit/s , no parity, 8 data bits, 1 stop bit | |
| Input/Output | ||
| Synchronization | bi-directional 0 level -UB...+1 V 1 level: +4 V...+UB input impedance: > 12 KOhm synchronization pulse: ≥ 100 µs, synchronization interpulse period: ≥ 2 ms |
|
| Synchronization frequency | ||
| Common mode operation | max. 95 Hz | |
| Multiplex operation | ≤ 95 Hz / n , n = number of sensors , n ≤ 5 |
|
| Output | ||
| Output type | 1 current output 4 ... 20 mA 1 voltage output 0 ... 10 V |
|
| Resolution | evaluation range [mm]/4000, but ≥ 0.05 mm | |
| Deviation of the characteristic curve | ≤ 0.2 % of full-scale value | |
| Repeat accuracy | ≤ 0.1 % of full-scale value | |
| Load impedance | current output: ≤ 500 Ohm Voltage output: ≥ 1000 Ohm |
|
| Temperature influence | ≤ 2 % from full-scale value (with temperature compensation) ≤ 0.2 %/K (without temperature compensation) |
|
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 5-pin | |
| Protection degree | IP65 | |
| Material | ||
| Housing | stainless steel (1.4305 / AISI 303) PBT plastic parts |
|
| Transducer | epoxy resin/hollow glass sphere mixture; polyurethane foam | |
| Mass | 170 g | |
| Instruction leaflets | Language | File Type | File Size |
| Beipackzettel/Instruction leaflet | ALL | 672 KB | |
| Instructions, Short instructions, Safety information | |||
| Manual ULTRA2001 | ENG | 1494 KB | |
| Handbuch ULTRA2001 | GER | 2359 KB | |
| CAD | File Type | File Size |
| 3D Modell/3D model | IGS | 71 KB |
| 3D Modell/3D model | STP | 43 KB |
| Certificates | Certificate No. | File Type | File Size |
| US CA UL General Purpose | E87056 | LINK | --- |
| Europe Pepperl+Fuchs 2004/108/EC (EMC) Declaration of Conformity | PF 08 CERT 1262 | 357 KB | |
| US CA CSA | 1007121 (LR96321-2) | 101 KB |
| Software Tools | Release Info | File Type | File Size |
| Software ULTRA 3000/Software ULTRA 3000 | V1.2.7 | ZIP | 2793 KB |
| Accessories | Name |
| BF 30 | Mounting flange |
| BF 30-F | Mounting flange |
| BF 5-30 | Mounting flange |
| M-105 | Sensor well |
| UVW90-M30 | Ultrasonic -deflector |
| UVW90-K30 | Ultrasonic -deflector |
| ULTRA3000 | Service program |
| UC-30GM-R2 | Interface cable |
| DA5-IU-2K-V | Process control and indication equipment |
| V15-G-2M-PVC | Female connector |
| V15-W-2M-PUR | Female connector |