Serviceline Industrial Sensors
Serviceline Explosion Protection
Not available for purchase
Not available for purchase

Ultrasonic sensor UCC2500-50GK-B26-V15-Y70117804

UCC2500-50GK-B26-V15-Y70117804
  • Thread M50
  • PTFE coated transducer
  • Serial Interfaces
  • Temperature compensation
  • Customer-specific configuration

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  UCC2500-50GK-B26-V15-Y70117804

Product Description
Single head system
General specifications
Sensing range150 ... 2500 mm
Dead band0 ... 150 mm
Standard target plate100 mm x 100 mm
Transducer frequencyapprox. 120 kHz
Electrical specifications
Operating voltage3 ... 5.5 V DC
No-load supply current≤ 70 mA at 3.3 V DC
Power consumption≤ 250 mW in the measurement operating mode
Time delay before availability≤ 70 ms
Interface
Interface typeUART 3.3V
Transfer rate19.2 kBit/s (8N1)
Cycle time55 ms
Resolution10 mm (corresponding to 1 LSB)
Temperature influence4 % of full-scale value over the entire temperature range
Input
Input typePhysical LIN interface
Functionfor Software Update/s
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN IEC 60947-5-2:2020 : chapter 8.2.6.2.2, 8.2.6.2.3, 8.2.6.3
The sensor is designed to be supplied by a battery. The sensor signals are further processed in a control unit, which is also responsible for EMC protection.
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection typeConnector plug M12 x 1 , 5-pin
Degree of protectionIP67
Material
HousingPBT
Transducerepoxy resin/hollow glass bead mixture; Polyurethane foam, PTFE coated
Mass115 g
Dimensions
Height44 mm
Width60 mm
Diameter60 mm
Construction typeCylindrical, thread M 50
Factory settings
Default settingTemperature compensation
Address setting 7
General information
Scope of deliverySeal

Classifications

SystemClasscode
ECLASS 13.027272803
ECLASS 12.027272803
ECLASS 11.027272803
ECLASS 10.0.127272803
ECLASS 9.027272803
ECLASS 8.027272803
ECLASS 5.127272803
ETIM 9.0EC001849
ETIM 8.0EC001849
ETIM 7.0EC001849
ETIM 6.0EC001849
ETIM 5.0EC001849
UNSPSC 12.141111960

Details: UCC2500-50GK-B26-V15-Y70117804

Function

The distance measurement is carried out over the runtime of the ultrasonic impulse. A measuring cycle is triggered by sending a start telegram. Once the measurement has been taken, the result is returned in 8-bit form.

Approvals: UCC2500-50GK-B26-V15-Y70117804

Language Selection:
Declaration of ConformityCertificate No.LanguageFile TypeFile Size
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-6779ALLPDF148 KB
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F)DOC-6780ALLPDF157 KB
USi-safety Sensor System

The USi-safety ultrasonic sensor system is breaking new ground for safety applications—whether in challenging, dusty environments or in outdoor areas.

Pepperl+Fuchs offers you various downloadable documents containing knowledge on ultrasonic sensors.