| General specifications |
| Switching element function | analog, current or voltage output |
| Object distance | 0.5 ... 3 mm , recommended: 2 mm |
| Measurement range | 0 ... 104 mm |
| Linearity range | 1 ... 103 mm |
| Nominal ratings |
| Operating voltage | 18 ... 30 V DC |
| Reverse polarity protection | reverse polarity protected |
| Linearity error | within measuring range: ± 0.8 mm within linearity range: ± 0.4 mm |
| Repeat accuracy | ± 0.1 mm |
| Resolution | 125 µm |
| Temperature drift | ± 0.5 mm (-25 °C ... 70 °C) |
| No-load supply current | ≤ 40 mA |
| Operating voltage display | LED green |
| Functional safety related parameters |
| MTTFd | 320 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Analog output |
| Output type | 1 current output: 4 ... 20 mA 1 voltage output: 0 ... 10 V |
| Load resistor | current output: ≤ 400 Ω voltage output: ≥ 1000 Ω |
| Short-circuit protection | voltage output: pulsing |
| Compliance with standards and directives |
| Standard conformity | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 |
| Approvals and certificates |
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
| Ambient conditions |
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
| Connection type | connector M12 x 1, 4-pin |
| Protection degree | IP67 |
| Material | |
| Housing | ABS |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) |