| Directive conformity |
| Electromagnetic compatibility | |
| Directive 2004/108/EC | EN 61326-1:2006 |
| Conformity |
| Electromagnetic compatibility | NE 21:2006 |
| Protection degree | IEC 60529 |
| Ambient conditions |
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) |
| Mechanical specifications |
| Protection degree | IP20 |
| Connection | hazardous area connection (field side): plugable screw terminals, blue safe area connection (control side): SiC plug, 20-pin
|
| Material | housing: polycarbonate, 30 % fiberglass reinforced |
| Mass | approx. 450 g |
| Dimensions | 159 x 155 x 153 mm (L x W x H) , height including module assembly |
| Mounting | DIN rail mounting |
| Data for application in connection with Ex-areas |
| EC-Type Examination Certificate | CESI 06 ATEX 022 , for additional certificates see www.pepperl-fuchs.com |
| Group, category, type of protection | II (1)GD [Ex ia] IIC; [Ex iaD]
I (M1) [Ex ia] I |
| Safe area | |
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) |
| Electrical isolation | |
| Field circuit/control circuit | safe galvanic isolation acc. to IEC 60079-11, voltage peak value 375 V |
| Directive conformity | |
| Directive 94/9/EC | EN 60079-0:2006, EN 60079-11:2007, EN 60079-26:2007 , EN 61241-0: 2006, EN 61241-11: 2006 , EN 50303:2000 |
| International approvals |
| UL approval | |
| Control drawing | 116-0327 |
| IECEx approval | IECEx CES 06.0003 |
| Approved for | [Zone 0] [Ex ia] IIC, [Ex iaD], [Ex ia] I |