| General specifications | ||
| Effective detection range | 0.2 ... 20 m | |
| Light source | IRED | |
| Light type | modulated infrared light | |
| Safety type according to IEC/EN 61496 | 4 | |
| Marking | CE | |
| Target size | 50 mm | |
| Beam spacing | 400 mm | |
| Number of beams | 3 | |
| Operating mode | can be selected with or without start/restart disable | |
| Angle of divergence | < 5 ° | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 3 | |
| Performance level (PL) | PL e | |
| Category | Cat. 4 | |
| Mission Time (TM) | 20 a | |
| PFHd | 5.8 E-9 | |
| Indicators/operating means | ||
| Diagnostics display | 7-segment display in receiver | |
| Function display | in receiver: LED red: OSSD off LED green: OSSD on LED yellow: Protected area free, system start-ready |
|
| Pre-fault indication | LED orange | |
| Electrical specifications | ||
| Operating voltage | 24 V DC (-30 %/+25 %) | |
| Input | ||
| Function input | Start release | |
| Output | ||
| Safety output | 2 separated fail safe semiconductor outputs | |
| Signal output | 1 PNP, max. 100 mA for start readiness | |
| Switching voltage | Operating voltage -2 V | |
| Switching current | max. 0.5 A | |
| Mechanical specifications | ||
| Protection degree | IP67 | |
| Connection | Emitter: M12 connector, 4-pin Receiver: M12 connector, 8-pin | |
| Manuals | Language | File Type | File Size |
| Handbuchergänzungen (EN ISO 13849)/Manual update (EN ISO 13849) | ALL | 211 KB |
| Certificates | Certificate No. | File Type | File Size |
| USA UL | E215245 | LINK | --- |
| EU Pepperl+Fuchs Declaration of Conformity | PF 12 CERT 2182 | 375 KB | |