Serviceline Information


  • Evaluation unit for security through-beam sensors SLA5(S) and SLA40; for safety light grids SLP, for safety light curtains SLC; for switching pads and emergency stop buttons of categories 2 and 4
  • 4 sensor channels
  • Self-monitoring (type 4 according to IEC/EN 61496-1)
  • Operating mode can be selected by means of DIP switches
  • Start/Restart disable
  • Relay monitor
  • Sequential and parallel muting in various operating modes
  • Double muting
  • Emergency muting for the correction of the material jam
  • Pre-fault indication
  • Clearly visible LED functional display
  • 7-segment diagnostic display
  • Safety outputs OSSD, external status displays OSSD

Datasheet as PDF in following languages:


Technical Data: SB4-OR-4XP-4M

Product Description
Safety control unit
General specifications
Operating modeStart/restart disable, relay monitor, muting operating modes
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.5 E-9
Indicators/operating means
Diagnostics display7-segment display
Function displayLED red: OSSD OFF
LED green: OSSD ON
Yellow LED: start readiness channel 1 - 4
LED yellow: switching state (receiver)
Pre-fault indicationLED yellow flashing: Indicator lamp channel 1 ... 4
Electrical specifications
Operating voltage24 V DC, ± 20 %
Output
Safety output2 relay outputs, force-guided NO-contact
Signal output1 PNP each, max. 300 mA for start readiness, OSSD on, OSSD off, muting lamp
Switching voltage10 V ... 250 V AC/DC
Switching currentmin. 10 mA , max. 6 A AC/DC
Mechanical specifications
Protection degreeIP20
Connectionscrew terminals , lead cross section 0.2 ... 2 mm2

Documents: SB4-OR-4XP-4M

Instructions, Short instructions, Safety informationLanguageFile TypeFile Size
Operating instructions Modular control system SB4 SafeBoxENGPDF1792 KB
Betriebsanleitung SB4 SafeBoxGERPDF1213 KB
Manuals
Handbuchergänzungen (EN ISO 13849)/Manual update (EN ISO 13849)ALLPDF211 KB
Product information
Product information Safebox SB4ENGPDF671 KB
Produktinformation Safebox SB4GERPDF677 KB

CAD+CAE: SB4-OR-4XP-4M

CADFile TypeFile Size
3D Modell/3D modelIGS2714 KB
3D Modell/3D modelSTP1058 KB

Approvals+Certificates: SB4-OR-4XP-4M

CertificatesCertificate No.File TypeFile Size
US CA UL photoelectric safety sensorsE215245LINK---
Europe TÜV SÜDZ10110520068027PDF484 KB
USA ULE215245LINK---
EU Pepperl+Fuchs Declaration of ConformityPF 12 CERT 2190PDF364 KB
EU Pepperl+Fuchs Declaration of ConformityPF 12 CERT 2191PDF327 KB

Associated Products: SB4-OR-4XP-4M

Matching system componentsName
SLA12-LAS/35/124Safety thru-beam sensor with laser
SLA12/115Safety thru-beam sensor
SLA12/124Safety thru-beam sensor
SLA29/105/106Safety thru-beam sensor
SLA29/106/116Safety thru-beam sensor
SLA29/116Safety thru-beam sensor
SLA29/35/105/106Safety thru-beam sensor
SLA29/35/73c R=65mSafety thru-beam sensor
SLA29/73cSafety thru-beam sensor
SLA29/35/116 R=65mSafety thru-beam sensor
SLA12-LAS/124Safety thru-beam sensor with laser