Convergent mode sensor, 100 mm adjustable detection range, red light, light/dark on, NPN output, fixed cable, Miniature design, Diffuse mode sensor with long, narrow light spot, Easy to use, Very bright, highly visible light spot, Full metal thread mountingfa
Convergent mode sensor, 100 mm adjustable detection range, red light, light/dark on, NPN output, M8 plug, Miniature design, Diffuse mode sensor with long, narrow light spot, Easy to use, Very bright, highly visible light spot, Full metal thread mountingfa
Convergent mode sensor, 100 mm adjustable detection range, red light, light/dark on, PNP output, M8 plug, Miniature design, Diffuse mode sensor with long, narrow light spot, Easy to use, Very bright, highly visible light spot, Full metal thread mountingfa
Convergent beam sensor, 100 mm adjustable detection range, blue light, light/dark on, PNP output, M8 plug, Miniature design, Diffuse mode sensor with long, narrow light spot, Easy to use, Very bright, highly visible light spot, Full metal thread mountingfa
Convergent beam sensor, 100 mm adjustable detection range, blue light, light/dark on, NPN output, fixed cable, Miniature design, Diffuse mode sensor with long, narrow light spot, Easy to use, Very bright, highly visible light spot, Full metal thread mountingfa
Convergent beam sensor, 100 mm adjustable detection range, blue light, light/dark on, PNP output, fixed cable, Miniature design, Diffuse mode sensor with long, narrow light spot, Easy to use, Very bright, highly visible light spot, Full metal thread mountingfa
Convergent beam sensor, 100 mm adjustable detection range, blue light, light/dark on, NPN output, M8 plug, Miniature design, Diffuse mode sensor with long, narrow light spot, Easy to use, Very bright, highly visible light spot, Full metal thread mountingfa
Pepperl+Fuchs provides smart solutions for industrial communcation-based IIoT applications in hazardous areas ... Nameplate Sensor of the ML100 series with digital nameplate Based on the unique identifier standardized in the IEC 61406 standard, the AAS of physical objects can be accessed automatically. The digital nameplate is a unified submodel of the AAS which makes ...
See Overview: Are you looking for a mobile solution for use in harsh industrial environments up to Zone 1/21 and Division 1? Get an overview of the full range of intrinsically safe Android and Windows ... for: Zone 2, Division 2, Class I, II, III, GRPS A–G, T4, T135 °C Class I, Group IIC T4 Tab-IND—Windows Tablet for Non-Ex Applications The slim Windows-based devices in the Tab-IND series are available with an 8-inch and 10-inch display and offer numerous ...
Explore the Pepperl+Fuchs knowledge base to learn more about the different versions of inductive sensors ... distance (sr) under set conditions. The value defines the switch point accuracy of successive switch events over a period of eight hours at an ambient temperature of +23 °C ±5 °C and at a constant operating voltage. Switching Hysteresis According to EN ...
Two new CB10 AS-Interface modules enable the integration of 3-wire sensors and emergency stop buttons according to SIL 3/PL e Learn more about their features and the fields of application ... -safe installation . The wiring has also been optimized so that only two cores are required for the ASi connection—a common PLUS line for +24 V and four input/output signal lines each. Depending on the version, between eight and twelve leads ...
To meet the different requirements of a wide range of applications and ambient conditions, Pepperl+Fuchs has developed slim Ethernet IO modules and powerful I/O hubs paving the way for transparent dat ... Modules and I/O Hubs 8-port Ethernet IO modules with integrated IO-Link master and a slim, 30 mm width I/O hubs with IO-Link interface for easily connecting up to 128 digital I/Os to a control system Rugged molded metal housing for use in harsh industrial ...
See Overview: When considering future Industry 40 scenarios, flexible automation solutions and real-time data transmission become more important than ever Ethernet IO modules from Pepperl+Fuchs prov ... . Up to eight IO-Link devices can be directly connected—four channels are available for sensor technology and four for actuators. The IO-Link master makes seamless parameterization, diagnostics, and predictive maintenance possible down to the sensor ...
See Overview: Pepperl+Fuchs Canada offers LB Remote I/O for Zone 2, Zone 22 or the safe area ... relay outputs with Ex nA terminals . They are available in 4- and 8-channel versions. Power Supply This 24V remote I/O power supply module in type of protection Ex nA feeds the I/O modules and com units/gateways that are mounted ...
Explore the Pepperl+Fuchs knowledge base to learn more about the electrical connections of inductive sensors ... Residual current 1.5 mA Operating current 5 mA ... 500 mA Direct-Current Voltage 8 V DC Sensor type NAMUR, N, 1N, SN, S1N EN 60947-5-6 Wiring diagram according to EN 60947-5-2 NC contact or NO contact Example: NC contact N/N0 or SN Typical data Rated ...
See Overview: Pepperl+Fuchs Canada offers FOUNDATION Fieldbus H1 - Explosion Protection for Zone 0/ Div 1 ... . See the download link at the end of the page. Best availability through integrated diagnostics The FieldBarrier selectable with 8, 10, or 12 outputs The FieldBarrier with 8, 10, or 12 outputs offers several diagnostics and protection functions. It protects fieldbus ...
Data Matrix encodes characters in the form of a bit sequence The actual size of the code depends on many independent factors These include the quantity of data, type of data and the printing techniq ... 6mm 3.8mm x 3.8mm 20x20 44/31 a) 5 dots b) 4 dots c) 10 dots 8 dots 5 dots 0.42 0.33 0.21 8.4mm x 8.4mm 6.6mm x 6.6mm 4.2mm x 4.2mm 22x22 60/43 a) b) c) 9.2mm x 9.2mm 7.3mm x 7.3mm 4.6mm x 4.6mm 24x24 72/52 a) b) c) 10.1mm x 10.1mm 7.9mm x ...
41-50/85Items Per Page:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.