Datasheet excerpt: Technical data of  WCS-BT111

Product Description
WCS Bus terminal
Ambient conditions
Operating temperature-40 ... 70 °C (-40 ... 158 °F)
Relative humidity90 % at 20 °C (68 °F) DIN EN 60068-2-3, no moisture condensation
Mechanical specifications
Connection typescrew terminals , 16-pin
Cable diameter5 ... 9 mm
Cable glandPG9 cable gland
Degree of protectionIP65
MaterialAluminum
Mass200 g

Classifications

SystemClasscode
ECLASS 13.027260190
ECLASS 12.019070403
ECLASS 11.019070403
ECLASS 10.0.119070403
ECLASS 9.027279090
ECLASS 8.027279290
ECLASS 5.127279201
ETIM 9.0EC003015
ETIM 8.0EC003015
ETIM 7.0EC003015
ETIM 6.0EC003015
ETIM 5.0EC002585
UNSPSC 12.131251501