CB10 safety module, 2 safety-related inputs and 1 conventional electronic output
Key Benefits at a Glance
- Connection of contact safety switches, e.g. EMERGENCY STOP button
- Modular safety solution
- Ultra-compact enclosure
- Applications up to Cat. 4, PL e/SIL 3









Note
All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
EN
- EN
- DE
- FR
Technical data of VAA-2E1A-CB10-SJ/E2J-FL
| Node type | Safety-Slave | |
| AS-Interface specification | V3.0 | |
| Required gateway specification | ≥ V2.1 | |
| UL File Number | E223772 |
| Safety Integrity Level (SIL) | SIL 3 | |
| Performance level (PL) | PL e | |
| Category | Cat. 4 | |
| MTTFd | no significant contribution to MTTFd of the overall system | |
| Mission Time (TM) | 20 a |
| LED FAULT | error display; LED red red: communication error or address is 0 | |
| LED PWR | AS-Interface voltage; green LED green: voltage OK flashing green: address 0 | |
| LED IN | switching state (input); 2 LED yellow | |
| LED OUT | Switching state (output); LED yellow |
| Rated operating voltage | Ue | 26.5 ... 31.6 V from AS-Interface (PELV) |
| Rated operating current | Ie | ≤ 40 mA (without inputs/outputs)/max. 160 mA |
| Protection class | III | |
| Surge protection | Ue: Over voltage category III, safe isolated power supplies (PELV) | |
| Rated insulation voltage | 32 V | |
| Pulse withstand voltage | 0.8 kV |
| Number/Type | 2 safety-related inputs for mechanical contacts, crossed-circuit monitored: 2 single-channel contacts: Up to category 2/PLc in accordance with ISO 13849-1 or SIL 1 in accordance with IEC 62061 1 two-channel contact: Up to category 4/PLe in accordance with ISO 13849-1 or SIL 3 in accordance with IEC 62061 | |
| Supply | from AS-Interface | |
| Voltage | 20 ... 30 V DC pulsed | |
| Current | input current limited ≤ 15 mA, short-circuit protected |
| Number/Type | 1 conventional electronic output, PNP , overload and short-circuit resistant | |
| Supply | from AS-Interface | |
| Voltage | (UASI - 7.0 V) ≤ UOUT ≤ UASI | |
| Current | ≤ 100 mA |
| Electromagnetic compatibility | |||||
| |||||
| Degree of protection | EN 60529:2000 | |
| Fieldbus standard | EN 62026-2:2013 | |
| Electrical safety | IEC 61140:2009 | |
| Emitted interference | EN 61000-6-4:2007 | |
| AS-Interface | EN 62026-2:2013 | |
| Noise immunity | IEC 62026-2:2013 EN 61326-3-1:2017 EN 61000-6-2:2005 | |
| Functional safety | EN ISO 13849-1:2023 EN IEC 62061:2021 |
| Profile | S-7.B | |||||||||||||
| IO code | 7 | |||||||||||||
| ID code | B | |||||||||||||
| ID1 code | F | |||||||||||||
| ID2 code | 0 | |||||||||||||
| Data bits (function via AS-Interface) | InputOutput | |||||||||||||
| ||||||||||||||
| Parameter bits (programmable via AS-i) | function | |||||||||||||
| ||||||||||||||
| UL approval | Protection class IP20 is not included in the UL approval. The protection class is tested by Pepperl+Fuchs. |
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
| Relative humidity | 85 % , non-condensing | |
| Climatic conditions | For indoor use only | |
| Altitude | ≤ 5000 m above MSL | |
| Shock and impact resistance | 30 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks | |
| Vibration resistance | 0.35 mm 10 ... 57 Hz , 5 g 57 ... 2000 Hz, 10 cycles | |
| Pollution degree | 2 |
| Degree of protection | IP20 according to EN 60529 | ||||||||||
| Connection | 200 mm, PVC cable 0.5 mm2 | ||||||||||
| Material | |||||||||||
| |||||||||||
| Mass | 28 g | ||||||||||
| Dimensions | |||||||||||
| |||||||||||
| Cable length | Input , output: max. 30 m | ||||||||||
| Note | This device is maintenance-free. If the device is used in a manner not specified by the manufaturer, the protection provided by the device may be impaired. | ||||||||||