Not available for purchase: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometerpa
Not available for purchase: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Not available for purchase: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Not available for purchase: 1-channel signal conditioner, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters, current and voltage sources, Current and voltage output, Housing width: 20 mm, Number of channels: 1-channel, Rated voltage: 19 ... 90 V DC / 48 ... 253 V AC, Field device: 2-wire transmitter, Field device [2]: 3-wire transmitter, Field device [3]: current source, Signal: 0/4 ... 20 mA, Signal [2]: 0/2 ... 10 V, Signal: 1 x 0/4 ... 20 mA (current source), Signal [2]: 1 x 0/2 ... 10 Vpa
Not available for purchase: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Not available for purchase: 2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact), Reversible mode of operationpa
Not available for purchase: Switching function: Normally open/closed (NO/NC) programmable, Output type: AS-Interface, Installation: non-flush, Output type: 2-wire, Construction type: VariKont L®, Series: VariKont L®, Operating voltage: 26.5 ... 31.9 V via AS-i bus system, Type of voltage: DC, Connection type: Connector plug M12 x 1 , 4-pin, Housing material: PA, Degree of protection: IP67fa
Not available for purchase: Diffuse sensor with measurement core technology, large housing design, background suppression and 3 more adjustable operating modes, IO-Link interface, 800 mm adjustable detection range, red light, 2 push-pull outputs, fixed cable, Cost-optimized series for standard tasks, Sensing-by-ranging functionality, IO-Link interface for service and process data, PowerBeam transmitter LED, Large adjustment range can be precisely definedfa
Looking for an agency approval or certification on a Pepperl+Fuchs product? Start your search here ... can always search for a model number using the search box located in the upper right corner of our website, or use the products menu to navigate to specific product families and their models. You can also start searching here: ...
Looking for a datasheet or cut sheet on a Pepperl+Fuchs product? Start your search here ... Download a Datasheet Looking for a datasheet or cut sheet on a product? Datasheets and model numbers go together! Each of our products has a datasheet providing technical data. You can always search for a model number using the search box located in ...
Fitting ABB’s 800xA control system with physical layer diagnostics is easy with the free ADM package from Pepperl+Fuchs ... are eliminated and the required time for segment commissioning is reduced by up to 80 %. Expert system for fast troubleshooting For fieldbus experts: The embedded oscilloscope provides detailed insights Using the FieldConnex® Advanced Diagnostic ...
See Overview: Pepperl+Fuchs offers a wide range of photoelectric sensors designed for the convenient and safe operation of industrial doors, gates, escalators, elevators and lifts ... of people or vehicles to overhead industrial doors , or sensing between elevator doors is the topic, we have the products. Using various sensor technologies, we offer both manufacturers and users the broadest line of these powerful sensors. More ...
Pepperl+Fuchs has industrial sensors for customized or standard solutions for digital printing and ATM machines ... consumables by tracking and tracing. Ink substances are also detected through toner cartridges using capacitive sensors . Click on the green numbers to jump to your application in digital printing or ATM! Feeder system applications Double Sheet Detection ...
Pepperl+Fuchs offers a wide variety of industrial sensors for sheet fed printing applications ... directly while ignoring reflective surfaces close to the target Enhanced edge detection using background suppression sensors Fast response time Cylinder and Part Position Sensor Solution: Inductive sensors, encoders Customer Benefits: Precise detection of ...
See Overview: Com units for PROFIBUS and MODBUS RTU - Connect Remote I/O to Control System/ PLC/ PC ... measured and setpoint values, the gateways transmit auxiliary variables, configuration and diagnostic data from HART-compatible field devices using the integrated HART-IP interface. Com units are available for different industrial communication protocols ...
A low Safety Integrity Level, or SIL requirement (SIL 1) means that only a comparably low risk reduction is necessary ... quantified using risk analysis methods that deliver results in the form of a SIL requirement . A low SIL requirement (SIL 1) means that only a comparably low risk reduction is necessary, whereas a higher SIL (for example SIL 3) requires a greater degree of ...
See Overview: Pepperl+Fuchs offers vibration limit switches for liquid level measurement ... fluctuations in the physical properties of the medium. Operation mode The two paddles of a vibrating fork are actuated using a piezoelectric source. In air the vibrating fork vibrates at its resonance frequency. When it is immersed in rising liquid, the ...
See Overview: Accessories for AS-Interface include handheld programming tools, network evaluation software, flat cable, mounting bases, adapters & splitter boxes ... modules or even individual networks is particularly easy because the handheld is operated using one hand. AS-Interface diagnosis and parameterization tools AS-Interface analyzer The AS-Interface analyzer allows online monitoring of communication in the ...
211-220/228Items Per Page:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.