Not available for purchase: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometerpa
Not available for purchase: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Not available for purchase: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Not available for purchase: 1-channel signal conditioner, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters, current and voltage sources, Current and voltage output, Housing width: 20 mm, Number of channels: 1-channel, Rated voltage: 19 ... 90 V DC / 48 ... 253 V AC, Field device: 2-wire transmitter, Field device [2]: 3-wire transmitter, Field device [3]: current source, Signal: 0/4 ... 20 mA, Signal [2]: 0/2 ... 10 V, Signal: 1 x 0/4 ... 20 mA (current source), Signal [2]: 1 x 0/2 ... 10 Vpa
Not available for purchase: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Not available for purchase: 2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact), Reversible mode of operationpa
Not available for purchase: Switching function: Normally open/closed (NO/NC) programmable, Output type: AS-Interface, Installation: non-flush, Output type: 2-wire, Construction type: VariKont L®, Series: VariKont L®, Operating voltage: 26.5 ... 31.9 V via AS-i bus system, Type of voltage: DC, Connection type: Connector plug M12 x 1 , 4-pin, Housing material: PA, Degree of protection: IP67fa
Not available for purchase: Diffuse sensor with measurement core technology, large housing design, background suppression and 3 more adjustable operating modes, IO-Link interface, 800 mm adjustable detection range, red light, 2 push-pull outputs, fixed cable, Cost-optimized series for standard tasks, Sensing-by-ranging functionality, IO-Link interface for service and process data, PowerBeam transmitter LED, Large adjustment range can be precisely definedfa
Functional principles of Pepperl+Fuchs' Pulse Ranging Technology (PRT) are explained ... process, the emission and reception times are detected with a high degree of precision . From the values determined, the distance to the object is calculated using the runtime of the light pulses . If the object is close, the light propagation time is ...
Photoelectric sensors with Pulse Ranging Technology (PRT) are ideal for distance measurement ... the object. What's more, the PRT sensors are extremely versatile . From distance sensors to high-end measurement technology, a host of different requirements can be met using the same method of measurement. PRT—technology that is setting new standards ...
SmartRunner 3-D is the latest 3-D vision sensor available with time of flight and stereo vision technology Learn more about it ... tools when a device is exchanged. Intuitive ViSolution Software All SmartRunner Explorer 3-D sensors are configured using the Pepperl+Fuchs software ViSolution. This free software tool features a clear design, intuitive user guidance, and user-friendly ...
Industrial FMCW radar sensors from Pepperl+Fuchs feature a high-read range and are ideally suited for integration into mobile machines ... of 70 m² used as a reference. Smaller detection ranges are given by objects with a lower RCS or by using smaller corner reflectors (here 0.5 m² as an example). Measuring Characteristics To learn more about reflection properties and the use of corner ...
Learn how Pepperl+Fuchs supports automated production of PEM electrolysis stacks for hydrogen generation ... of water. In order to produce green hydrogen , water is split into hydrogen and oxygen molecules in an electrolysis process using electricity from renewable energies . This is done, for example, with proton exchange membranes (PEMs) . These are ...
Pepperl+Fuchs ultrasonic sensors enable web tension feedback in plastic thermoforming, metal stamping, and paper converting processes ... distance to the loop, or signal when defined limits are reached via two switching outputs . You can configure the control parameters quickly and easily using the programming buttons or parameterization software . The benefits There are certain cases where ...
During the manufacturing of battery modules for electric vehicles, several prismatic battery cells are welded together To do this, the cells must be positioned correctly The VOS 2-D universal vision ... data should also be fully documented. The Solution VOS5000 in C-Mount Version with External Bar Lighting With the VOS 2-D universal vision sensor, all tasks can be completed using a single device. In the C-mount version VOS5000 , the device can be ...
Reliability Made Smart: The new intrinsically safe 5G smartphone for hazardous areas ... message via Ethernet APL on the 5G Smart-Ex 03 smartphone. Using unique identifiers, they can check which component sent the error message and gain access to valuable data from the field device. A management system thereby enables asset management and ...
Whether on-road or off-road, sensors used in mobile equipment must work reliably in harsh conditions Pepperl+Fuchs offers a broad portfolio of sensor solutions for mobile machines ... -safety system is ideally suited for challenging outdoor applications with safety requirements. A miniature sensor unit detached from the control interface allows the USi-safety to be used even in confined installations. Collision Avoidance Mobile ...
From reliable positioning and identification to guaranteeing smooth processes in conveyor technology and safety-critical applications—discover our comprehensive portfolio for the automotive industry ... , safety sensors check its final position. Reliable Safeguarding in Accordance with Category 3 PL d The USi-safety ultrasonic sensor system is breaking new ground for safety applications—whether in challenging, dusty environments or in outdoor areas ...
31-40/228Items Per Page:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.