Miniature photoelectric slot sensor for the detection of small parts, L design, fork width 5 mm, infrared light, PNP outputs, fixed cable, Miniature design, Optimized for the detection of small parts, High switching frequency, Simple and fast mounting, Clearly visible LED functional displayfa
Miniature slot sensor for small part detection, L design, 5 mm slot width, infrared light, PNP output, with 0.2 m fixed cable and M8 plug, 4-pin, Miniature design, Optimized for the detection of small parts, High switching frequency, Simple and fast mounting, Clearly visible LED functional displayfa
Miniature photoelectric slot sensor for the detection of small parts, L design, fork width 5 mm, infrared light, PNP outputs, fixed cable, Miniature design, Optimized for the detection of small parts, High switching frequency, Simple and fast mounting, Clearly visible LED functional displayfa
The ENA58IL series magnetic rotary encoders convinces with high resolutions and an accuracy of <01° Get to know the new benchmark for industry standard rotary encoders! ... encoder, with its accuracy of 0.1°, provides exact position data for the precise positioning of the bottles. Newspapers move at a speed of around 50 meters per second through offset presses. The movement of the press rollers has to be exactly matched ...
Explore the Pepperl+Fuchs knowledge base to learn more about the output types of inductive sensors ... the output connection to the supply voltage of the sensor when switched. The load is connected between the PNP output of the sensor and ground L-. Note: Sensors with PNP output tend to be used more frequently to prevent short circuits to ground. Example ...
Explore the Pepperl+Fuchs knowledge base to learn more about the power source of two-wire sensors ... , Pepperl+Fuchs offers two-wire sensors that have a particularly low residual current. Example: NBB10-30GS50-Z4L-V1. The "L" in the output name stands for low current. "Closed" Operating State In the "closed" operating state, the switching element ...
The Windows-based devices of the Tab-IND series are available with display sizes of 8 and 10 inch for use in non-ex applications, including intra- and transport logistics Learn more about the rugged ... devices are equipped with a 13 MP camera and a bright display with 700 and 800 cd/m² , which can also be operated with a pen or gloves. With a temperature range of -20 ... +50 °C , the tablets are equally suitable for industrial use and outdoor ...
With the VOC Industrial Event Camera, Pepperl+Fuchs is expanding its industrial vision portfolio The camera allows event-driven video recording up to 60 seconds before and after a trigger signal Get ... , is connected to the camera via the digital hardware input. Even more flexibility in use is provided by the high depth of field at 0.5 m to over 10 m mounting distance, the operating temperature range of –30 °C ... +50 °C and the large field of view ...
Discover the modular stainless steel enclosure series that provides a perfect base for individual terminal boxes, control stations or remote I/O field units ... of terminals and accessories available Control Stations Up to 102 operator elements per control station Various enclosure size options Ex db, Ex ib and Ex tb certified Installation in Zone 1, Zone 2, Zone 21 and Zone 22 IP66 Ambient temperature range: -50 … 55 ...
See Overview: Pepperl+Fuchs offers LB Remote I/O LB Remote I/O stations are mounted in hazardous areas Zone 2 or Zone 22 or in the safe area They form a modular signal conditioning system to interfa ... mounting. Terminal blocks, protective covers for terminal blocks, cold junction blocks, and a watchdog plug are also part of the portfolio. The product range is rounded out by a separation wall that is used to maintain the 50 mm clearance between ...
Bebco EPS portfolio provides reliable safety for Zones and Divisions applications, with a full range of Type X,Y, Z, Ex px, and Ex pz Each system has been designed and engineered with a user-friendly ... Bluetooth Universal power 20 to 30 VDC / 100 to 250 VAC. 50 to 60 HZ Up to SIL 2 acc. to IEC 61508 6000 Series Fully automatic Type X & Ex pxb purge and pressurization system for hazardous gas or dust applications 100% automatic purge and pressurization ...
Pepperl+Fuchs' AS-Interface switch cabinet modules KE5 Series are high-performing modules for switch cabinets and junction boxes ... additional installation space . With connection at the front of the device, modules can be mounted flush on the upper edge of the switch box or cabinet. Together with the narrow KE5 housing , <19 mm, you can achieve up to 50% space savings . A clearly colored allocation ...
Explore the Pepperl+Fuchs knowledge base to learn more about the electrical connections of inductive sensors ... to the numbering of the pins on the connector plugs. This does not apply to proximity sensors for AC and those with 3-pin 8 mm plugs. Switches without protective insulation require a protective conductor terminal for voltages above 50 V AC and 120 V DC. 2 AC ...
61-70/77Items Per Page:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.