Subrack for K-System, Replacement for subrack of the E-System, Max. 33 slots for isolators, Long design (300 mm mounting depth), Connection via marshalling patchboards, Partial and combined assembly possible, Complete wiring according to customer requirements, Allows to retain cable routing in the switch cabinet, No structural changes on the switch cabinet requiredpa
Subrack for K-System, Replacement for subrack of the E-System, Max. 33 slots for isolators, Long design (300 mm mounting depth), Connection via marshalling patchboards, With middle sheet and cable duct, Partial and combined assembly possible, Complete wiring according to customer requirements, Allows to retain cable routing in the switch cabinet, No structural changes on the switch cabinet requiredpa
Subrack for K-System, Replacement for subrack of the E-System, Max. 33 slots for isolators, Short design (211 mm mounting depth), Connection via terminal blocks, Partial and combined assembly possible, Complete wiring according to customer requirements, Allows to retain cable routing in the switch cabinet, No structural changes on the switch cabinet requiredpa
Subrack for K-System, Replacement for subrack of the E-System, Max. 33 slots for isolators, Short design (211 mm mounting depth), Connection via marshalling patchboards, Partial and combined assembly possible, Complete wiring according to customer requirements, Allows to retain cable routing in the switch cabinet, No structural changes on the switch cabinet requiredpa
With the KCD2-SCD-Ex1ES SMART current driver, Pepperl+Fuchs meets the boundary conditions of functional safety according to SIL 3 without the use of special emergency shutdown valves and safety shut-off valves ... by actuating these controllers with HART signals for partial stroke tests in addition to their actual function. These tests allow for functional inspection testing without shutting down the entire media supply and without redundant hardware. The KCD2-SCD-Ex1.ES ...
A combination of a pressure transmitter with a transmitter power supplyl is ideally suited for constantly monitoring the oil pressure in lubrication cycles ... power supply unit provides an intrinsically safe power supply and ensures that the data is reliably transmitted. KCD2-STC-Ex1.ES modules are typically used for this application. They are suitable for applications up to SIL 3 in accordance with IEC/EN ...
Identification tasks for code readers in factory automation are enormously diverse Whether standstill or high-speed, printed or directly marked codes, large distance, or minimum code size—the VOS Ide ... , output string formatting and multiwindow as well as multisensor mode Flexibly adaptable hardware and software Interfaces: Ethernet TCP/IP, PROFINET IO, EtherNet/IP™, RS-232 and I/Os. Code quality output based on ISO 15415, ISO 16022, ISO/IEC TR 29158 (AIM ...
Signal conditioners guarantee dependable conversion and transmission of signals in the vulcanization process during tire manufacturing Learn more about the application ... solution in this case. Various K-System signal conditioners could be used. The loop-powered RTD signal converter KFD0-TR-1 can be used as a direct replacement for a head-mount transmitter. One key advantage in comparison to competitors’ products ...
In the production processes of the automotive industry, components are automatically identified and guided to the next processing step in a targeted way The VOS-I vision sensor has been specially des ... with the applicable ISO/IEC TR 29158 standard (AIM DPM). For data communication, all relevant interfaces are available with I/O, Ethernet TCP/IP, PROFINET, EtherNet/IP, and RS-232. The powerful script function can be used to adapt the output string for integration ...
See Overview: Pepperl+Fuchs offers a wide range of frequency converters for our K-System isolated barriers ... an additional analog output for frequency evaluation and switch outputs for limit value functions. Timer KF**-DU-EX1.D The Timer module DU offers the following time functions: Passing contact Retriggerable passing contact Pickup delay Dropout delay Stepping function ...
Visit the "Functional Safety Hub" from Pepperl+Fuchs where you find safety assessed devices for process industry applications and also get access to helpful tools and brochures ... power supply unit provides an intrinsically safe power supply and ensures that the data is reliably transmitted. KCD2-STC-Ex1.ES modules are typically used for this application. They are suitable for applications up to SIL 3 in accordance with IEC/EN ...
Explore the Pepperl+Fuchs knowledge base to learn more about the power source of two-wire sensors ... from www.pepperl-fuchs.com . Sensor Connection—Example The following diagram is a sample circuit of a safety sensor with the KFD2-SH-EX1. The implemented safety logic should be considered functionally independent of the galvanic isolation for establishing intrinsic ...
The VisuNet GXP HMI Systems allow easy access to process information in Zone 1/21 ... product line, the VisuNet EX1. This means that users can retrofit existing installations easily via a drop in replacement, and are even able to continue using existing keyboards or barcode readers. Just like the larger 21,5" version of the display unit ...
1-9/9Items Per Page:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.