See Overview: The Bebco EPS® 6100 series was designed for use with large enclosures and some large motors, drives, and compressors in ATEX/IECEx Zone 1 or 2 explosion hazardous locations ... m³ (450 ft³) . The 6100 system consists of a control unit, enclosure protection vent, low pressure sensor, and optional temperature sensors. The configurable control unit features temperature and pressure monitoring and compensation, an extra ...
See Overview: Our Bebco EPS Ex pz purge system is designed to purge and pressurize the protected enclosure ... . The combination of automation and configurable functions support even the most difficult applications . Automatic systems for alarm, purging, and power to enclosure Enclosure sizes to 450 cu. ft . Conforms to NFPA 496 and ISA 12.4 standards IECEx and UL certified ...
See Overview: ... Zone 1/21 hazardous location to a non-hazardous area ATEX/IECEx certification for gas and dust and SIL 2 certified Operates on enclosure sizes up to 12.7 cubic meters (450 cubic ft.) Automatic monitoring and control of enclosure pressure and temperature ...
Find out more about the highlights and benefits of the ultrasonic technology ... , ultrasonic sensors are a versatile solution for numerous industrial applications. Models are available that can detect objects at a distance of up to 33 ft, and determine their distance to the sensor—with a minimal blind zone. Adjustable sound beam width ...
See Overview: The Bebco EPS 6500 Series Ex px purge and pressurization system provides reliable protection for operating general purpose electrical equipment in Zone 1/21 hazardous locations ... /21 hazardous location to a non-hazardous area ATEX/IECEx certification for gas and dust and SIL 2 certified Operates on enclosure sizes up to 12.7 cubic meters (450 cubic ft.) Automatic monitoring and control of enclosure pressure and temperature ...
See Overview: Pepperl+Fuchs offers a wide range of frequency converters for our K-System isolated barriers ... an additional analog output for frequency evaluation and switch outputs for limit value functions. Timer KF**-DU-EX1.D The Timer module DU offers the following time functions: Passing contact Retriggerable passing contact Pickup delay Dropout delay Stepping function ...
See Overview: Our Pepperl+Fuchs Bebco EPS 1000 series Type Z purge system is suitable for Class I, Division 2 to non-hazardous area applications & Class II, Division 2 to non-hazardous area applicatio ... and ISA 12.4 standards Enclosure volumes to 450 cu. ft Note: Vents are required for most Type Z purge enclosures Type Z purge system models - 1000 series 1001A : Class I Enclosure Volumes ≤ 2 ft3 and Class II Enclosure Volumes ≤10 ft3 , WPS Only 1001B ...
See Overview: Our Pepperl+Fuchs Bebco EPS 2000 series, Type Y purging system is an automatic system that will purge and pressurize the protected enclosure and maintain pressure within the enclosure ... standards Enclosure volumes to 450 cu. ft Note: Vents are required for most Type Y purge enclosures Type Y purge system models - 1000 series 1001A : Class I Enclosure Volumes ≤ 2 ft3 and Class II Enclosure Volumes ≤10 ft3 , WPS Only 1001B : Class II ...
See Overview: Bebco EPS Type Y purging system reduces the classification within the protected enclosure from Division 1 to Division 2 All equipment used within the enclosure must be Division 2 rated ... sizes to 450 cu. ft. UL, cUL, FM classifications Conforms to NFPA 496 and ISA 12.4 standards 3000 Series Type Y Purge System The Pepperl+Fuchs Bebco EPS 3000 series , Type Y purging system will purge and pressur ize the protected enclosure and maintain ...
Visit the "Functional Safety Hub" from Pepperl+Fuchs where you find safety assessed devices for process industry applications and also get access to helpful tools and brochures ... power supply unit provides an intrinsically safe power supply and ensures that the data is reliably transmitted. KCD2-STC-Ex1.ES modules are typically used for this application. They are suitable for applications up to SIL 3 in accordance with IEC/EN ...