1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 20 V DC ... 26.5 V DC, non-polarized, Fail-safe relay contact output for de-energized and energized to safe function , Test pulse immunity, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, ETS function (energized to safe), DTS function (de-energized to safe), DPS function (dual pole switching), Safety Integrity Level (SIL): SIL 3pa
Fire protection on ships is a very current and important issue Intelligent safety relays guaranteereliable switching processes and additional diagnostic functions Learn more about the latest additio ... or opens the circuit accordingly. Defective contacts are detected, and a fault is reported to the control system. After switching three times, the relay module is fully tested without any additional effort. The modules in the KFD2-RSH series also provide ...
Faulty fuel lines are common causes of fires in engine rooms KFD2-RSH-1*D* safety relays with dual redundant contacts from Pepperl+Fuchs enable the immediate shutdown of the fuel supply and offer maximum functional safety Learn more ... fuel, it is therefore important to immediately shut down the fuel pumps before any other measures are taken. This process must be fully automatic and take place properly even under critical operating conditions. The Solution KFD2-RSH-1.*D.* safety ...
The ETS safety relays (energized-to-safe) from Pepperl+Fuchs enable safe triggering of fire alarms and automatic extinguishing system in the event of a fire outbreak Learn more about the application ... in the event of a fire outbreak is safe signal transmission supplemented by galvanic isolation between the control and field circuits. The ETS safety relays (energized-to-safe) from Pepperl+Fuchs are designed precisely for this purpose. The KFD2-RSH-1.2E.L ...
Signal conditioners guarantee dependable conversion and transmission of signals in the vulcanization process during tire manufacturing Learn more about the application ... solution in this case. Various K-System signal conditioners could be used. The loop-powered RTD signal converter KFD0-TR-1 can be used as a direct replacement for a head-mount transmitter. One key advantage in comparison to competitors’ products ...
Visit the "Functional Safety Hub" from Pepperl+Fuchs where you find safety assessed devices for process industry applications and also get access to helpful tools and brochures ... requirement for alarm systems and automatic extinguishing devices being reliably activated is fault-free signal transmission between the field circuit and the control side, which are galvanically isolated from each other. KFD2-RSH-1.*D.* safety relays ...
1-5/5Items Per Page:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.