SMART Transmitter Power Supply, Output Current Sink
Not available for purchase: 1-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA, Terminal blocks with test sockets, Up to SIL3 acc. to IEC 61508, Housing width: 20 mm, Number of channels: 1-channel, HART communication, Rated voltage: 20 ... 35 V DC, Input signal: 0/4 ... 20 mApa
SMART Transmitter Power Supply, Output Current Sink
Not available for purchase: 1-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA, Terminal blocks with test sockets, Up to SIL3 acc. to IEC 61508, Housing width: 20 mm, Number of channels: 1-channel, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 3, Rated voltage: 20 ... 35 V DC, Field device: 2-wire transmitterpa
SMART Transmitter Power Supply, Output Current Sink
Not available for purchase: 1-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA, Terminal blocks with test sockets, Up to SIL3 acc. to IEC 61508, Housing width: 20 mm, Number of channels: 1-channel, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 3, Rated voltage: 20 ... 35 V DC, Field device: 2-wire transmitterpa
Learn more about the safe absolute linear positioning systems from Pepperl+Fuchs for safety applications up to SIL 3 and PL e ... . The absolute linear positioning systems safePXV, safePXV/PUS, and safeWCS/PUS guarantee safe position and speed detection up to SIL 3 and PL e , even in harsh environmental conditions. Highlights Safe absolute linear positioning systems up to SIL 3 and PL e ...
Fire protection on ships is a very current and important issue Intelligent safety relays guaranteereliable switching processes and additional diagnostic functions Learn more about the latest additio ... triggers and transmits these signals. A safety relay with a high degree of reliability in case of emergency is required to ensure that the signals are transmitted safely. The Solution The latest safety relays feature a sophisticated “One out of three” (1oo3 ...
SmartRunner 3-D is the latest 3-D vision sensor available with time of flight and stereo vision technology Learn more about it ... SmartRunner Explorer 3-D | Pepperl+Fuchs SmartRunner Explorer 3-D Benefits Video Technologies Features and Software Technical Details Applications Contact Us Infinite Possibilities SmartRunner Explorer 3-D with Stereo Vision and Time-of-Flight ...
The SmartRunner Explorer 3-D ensures automated loading and unloading of load carriers in material handling It delivers 3-d data for high-resolution detection during transfer ... . When unloading the pallet, it is necessary to detect whether the pallet has become detached from the fork . The Solution SmartRunner Explorer 3-D The SmartRunner Explorer 3-D vision sensor is mounted on the mast or between the vehicle’s fork arms. Its ...
See Overview: Pepperl+Fuchs offers flexible industrial vision solutions for a wide range of applications ... of the SmartRunner Explorer 3-D series are made for goods inspection on conveyor belts or for pick-and-place applications in robotics. The 3-D vision sensor delivers high-precision 3-D point cloud images in addition to 2-D images, and is available with stereo vision ...
See Overview: From goods inspection on conveyor belts to collision avoidance for AGVs—as a raw data sensor, the SmartRunner Explorer 3-D is suitable for a wide range of applications that require detailed contour detection Discover the 3-D vision ... technology or time-of-flight (ToF) technology and generates high-precision 3-D point cloud images in addition to 2-D images. Together with the integrated Ethernet Gigabit interface , 2-D and 3-D images can be generated significantly faster and without data ...
The inventor and pioneer in proximity sensors presents its new portfolio of inductive-cylindrical standard sensors ... : with the next generation of inductive sensors , Pepperl+Fuchs is now taking "the Original" to a new evolutionary level and presents its customers a portfolio of 3-wire / 4-wire sensors in unparalleled variance. A key benefit in developing the new portfolio ...
A combination of a pressure transmitter with a transmitter power supplyl is ideally suited for constantly monitoring the oil pressure in lubrication cycles ... Functional safety in accordance with SIL 3 Bidirectional HART communication Can be connected to a PLC or a control system (optional) ...
Faulty fuel lines are common causes of fires in engine rooms KFD2-RSH-1*D* safety relays with dual redundant contacts from Pepperl+Fuchs enable the immediate shutdown of the fuel supply and offer maximum functional safety Learn more ... fuel, it is therefore important to immediately shut down the fuel pumps before any other measures are taken. This process must be fully automatic and take place properly even under critical operating conditions. The Solution KFD2-RSH-1.*D.* safety ...
1-10/241Items Per Page:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.