Not available for purchase: Surge protection for 2 supply lines, Type 2 acc. to EN 61643-11, For TT and TN systems (230 V AC), Pre-wired unit, Operating state and fault indication of every protected line, Fault indication output, DIN rail mountable, Device type: type 2 acc. to EN 61643-11 class II acc. to IEC 61643-1, Number of protected supply lines: 2pa
Surge Protection Technology for Process Industry from Pepperl+Fuchs ... . Based on more than 20 years of experience , Pepperl+Fuchs has acquired significant know-how in surge protection. M-LB-4000 offers reliable diagnostics, easy handling and a space saving housing design. Discover the Pepperl+Fuchs surge protection portfolio ...
See Overview: Backplanes are holding LB Remote I/O Modules, Com units and power supplies ... For mounting the interface modules of the remote I/O LB system, Pepperl+Fuchs offers backplanes for use in Zone 2, Class I/Div. 2 explosion-hazardous areas . Different sizes are available as base or extension backplanes. They carry any combination ...
See Overview: Pepperl+Fuchs offers 24 VDC, 115 V AC and 230 VAC power supplies for our LB Zone 2 remote I/O systems ... As part of its LB system remote I/O solution , Pepperl+Fuchs offers a power supply for use in Zone 2, Class I/Div. 2 explosion-hazardous areas . This 24V remote I/O power supply in protection type Ex nA feeds the I/O modules and com units/gateways ...
See Overview: Our Pepperl+Fuchs Bebco EPS 1000 series Type Z purge system is suitable for Class I, Division 2 to non-hazardous area applications & Class II, Division 2 to non-hazardous area applications ... and ISA 12.4 standards Enclosure volumes to 450 cu. ft Note: Vents are required for most Type Z purge enclosures Type Z purge system models - 1000 series 1001A : Class I Enclosure Volumes ≤ 2 ft3 and Class II Enclosure Volumes ≤10 ft3 , WPS Only 1001B ...
See Overview: Our Pepperl+Fuchs Bebco EPS 2000 series, Type Y purging system is an automatic system that will purge and pressurize the protected enclosure and maintain pressure within the enclosure ... standards Enclosure volumes to 450 cu. ft Note: Vents are required for most Type Y purge enclosures Type Y purge system models - 1000 series 1001A : Class I Enclosure Volumes ≤ 2 ft3 and Class II Enclosure Volumes ≤10 ft3 , WPS Only 1001B : Class II ...
See Overview: Pepperl+Fuchs offers temperature input modules for our LB Zone 2 remote I/O systems 1- and 4-channel temperature input modules for Pt 100 resistance thermometers, slide wire sensors, thermocouples and mV signals ... of protection Ex i . These signal converters are rated for use in Zone 2, Class I/Div. 2 explosion-hazardous areas and allow connection of different resistance thermometers (2-, 3- and 4-wire Pt100 ... Pt1000), thermocouples, and mV signals. LB system remote I/O ...
See Overview: Pepperl+Fuchs offers relay output modules for our LB Zone 2 remote I/O systems 2-, 4- and 8- channel modules for valves, solenoid valves, optical and audible alarms ... in Zone 2, Class I/Div.2 explosions-hazardous areas , Pepperl+Fuchs provides relay outputs with Ex nA terminals . As part of the LB system remote I/O solution , our relay output modules are available in 4- and 8-channel versions , ensuring the highest ...
The WILSEN platform offers three LoRa-based, battery-powered sensor solutions for a wide range of M+O applications ... be covered. Three variants allow the right M+O sensor solution to be selected for the respective application. WILSEN.sonic: Smart Monitoring of Fill Levels and Distances Due to an integrated ultrasonic transducer, the WILSEN.sonic enables the detection ...
Pepperl+Fuchs' new PROFINET gateways open up the door for industry 40 applications in process automation ... of the segments not affected by the failure. Large Touch Display for On-Site Diagnostics and Status Information The LB and FB PROFINET gateways feature the largest touch display available on the market for this type of device. RGB LEDs and display symbols comply ...
See Overview: Pepperl+Fuchs offers com units for our LB Zone 2 remote I/O systems ... and FB8222B.1.EL PROFINET gateways connect the LB or FB remote I/O system. This way, the sensors and actuators connected to the remote I/O system are connected to a control system via a PROFINET network. The Shared Device function , which is standardized ...
1-10/218Items Per Page:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.