See Overview: Pepperl+Fuchs FieldBarriers for FOUNDATION Fieldbus H1 offer explosion protection for Zone 0/ Div 1 Each output of the FieldBarrier is intrinsically safe Field instrumentation can be installed in Zone 0/ Div 1 ... from intrinsic safety (Ex ia for Zone 0, Div. 1) at the output, it also provides short-circuit protection . It protects operations from hard short-circuits at the output of the FieldBarrier or the connected instrument. Installation-ready, pre-wired solutions ...
The new ICE11 IO-Link master for PLC-based applications is multiprotocol-capable and now supports not only PROFINET, EtherNet/IP, and MODBUS TCP but also EtherCAT and CC-Link IE Field Basic It can be used worldwide in various application areas ... . Highlights of the ICE11 IO-Link Master Multiprotocol for worldwide use: PROFINET, EtherNet/IP, EtherCAT, CC-Link IE Field Basic, and MODBUS TCP in one device Especially for time-critical applications: EtherCAT variant with extremely short cycle times ...
See Overview: Pepperl+Fuchs K-system signal converters receive signals from a hazardous area instrument ie, temperature sensors, potentiometers or load cells and then convert and condition them into signals such as 0/420mA or 0/210V ... Converters receive signals from a hazardous area instrument i.e., temperature sensors, potentiometers or load cells and then convert and condition them into signals such as 0/4…20mA or 0/2…10V. ...
See Overview: Pepperl+Fuchs offers analog output modules for our FB Zone 1 remote I/O systems, 1- and 4-channel to control 0/4-20 mA HART positioners, proportional valves and indicators ... See Overview: Pepperl+Fuchs offers analog output modules for our FB Zone 1 remote I/O systems, 1- and 4-channel to control 0/4-20 mA HART positioners, proportional valves and indicators. ...
The optical data couplers LS682 and LS684 give your application increased range, greater stability, and maximized uptime They allow stable data transmission over a distance from 0 to 300 m Virtually convince yourself of their easy handling ... reliability – even over long distances! Optimum use of existing space When mounting the optical data coupler, no minimum distance has to be considered since both, LS682 and LS684, ensure reliable data transmission beginning at distance 0. Make optimal ...
See Overview: Pepperl+Fuchs offers voltage input modules for our FB Zone 1 remote I/O systems 1-channel for connecting analog input signals with a voltage range of 0-10V ... and reverse motion while the other one changes with sideways motion. For this and other applications involving 0 V … 10 V voltage sources , Pepperl+Fuchs offers voltage inputs from our FB system remote I/O solution. These voltage input modules have type ...
See Overview: Pepperl+Fuchs offers analog input modules for our FB Zone 1 remote I/O systems, 1- and 4-channel for the connection of 2- and 4-wire HART transmitters and 0/4-20 mA signals ... . In these applications, the third wire is used for active return line current ranging from 4 mA … 20 mA or 0 mA … 20 mA. FB system remote I/O analog inputs are available in the following versions: 1-channel versions address the needs of users that appreciate granularity ...
See Overview: Pepperl+Fuchs offers analog input modules for our LB Zone 2/22, Class I, Div 2 remote I/O systems, 1- and 4-channel for the connection of 2- and 4-wire HART transmitters and 0/4-20 mA signals ... transmitters up to 23 mA. In these applications, the third wire is used for active return line current ranging from 4 mA … 20 mA or 0 mA … 20 mA. The LB system remote I/O analog inputs are available in the following versions: 1-channel versions address ...
Pepperl+Fuchs' F260 Series ultrasonic sensors are used to detect fill levels in a gravel silo ... , the maximum detection range of the 10 m sensors may be reduced to 6 m. The F260 Series offers the following versions for the analog output (including 2 switching outputs in NO or NC contact version): 4 mA … 20 mA, UCxxx-F65-IE..-V15 0 V … 10 V, UC10000 ...
See Overview: H-System repeaters from Pepperl+Fuchs transfer and isolate signals from hazardous areas to safe areas ... Isolated repeaters transfer and isolate signals from hazardous areas to safe areas. They transfer the following types of signals: mV signals from thermocouples and load cells 0…10V signals Voltage pulses Resistance from RTDs and potentiometers ...