1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 12.5 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 19 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connectionpa
1-channel signal conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA ... 20 mA, 2 relay contact outputs, Configurable by PACTware or keypad, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 40 mm, Number of channels: 1-channel, Trip relay, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Field device: resistance thermometerpa
1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA ... 20 mA, 2 relay contact outputs, Configurable by PACTware or keypad, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 40 mm, Number of channels: 1-channel, Trip relay, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connectionpa
Frequency Converter with Direction and Synchronization Monitor
2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Input frequency 1 mHz ... 1 kHz, Current output 0/4 mA ... 20 mA, Relay contact and transistor output, Start-up override, Configurable by PACTware or keypad, Line fault detection (LFD), Housing width: 40 mm, Number of channels: 2-channel, Trip relay, Start-up override, Frequency conversion, Rotation direction monitoring, Rotation speed monitoring, Synchronization monitoring, Slip monitoringpa
1-channel signal conditioner, Universal usage at different power supplies, Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA ... 20 mA, 2 relay contact outputs, Configurable by PACTware or keypad, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 40 mm, Number of channels: 1-channel, Trip relay, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 90 V DC / 48 ... 253 V ACpa
1-channel isolated barrier, Universal usage at different power supplies, Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA ... 20 mA, 2 relay contact outputs, Configurable by PACTware or keypad, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 40 mm, Number of channels: 1-channel, Trip relay, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 90 V DC / 48 ... 253 V ACpa
Frequency Converter with Direction and Synchronization Monitor
2-channel signal conditioner, Universal usage at different power supplies, Dry contact or NAMUR inputs, Input frequency 1 mHz ... 1 kHz, Current output 0/4 mA ... 20 mA, Relay contact and transistor output, Start-up override, Configurable by PACTware or keypad, Line fault detection (LFD), Housing width: 40 mm, Number of channels: 2-channel, Trip relay, Start-up override, Frequency conversion, Rotation direction monitoring, Rotation speed monitoring, Synchronization monitoringpa
Frequency Converter with Direction and Synchronization Monitor
2-channel isolated barrier, Universal usage at different power supplies, Dry contact or NAMUR inputs, Input frequency 1 mHz ... 1 kHz, Current output 0/4 mA ... 20 mA, Relay contact and transistor output, Start-up override, Configurable by PACTware or keypad, Line fault detection (LFD), Housing width: 40 mm, Number of channels: 2-channel, Trip relay, Start-up override, Frequency conversion, Rotation direction monitoring, Rotation speed monitoring, Synchronization monitoringpa
Single head system, IO-Link Interface for process data, parameterization and diagnosis, Programmable via DTM with PACTWARE, Programmable via IrDA (infrared interface), Series: -18GM, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Interface type: IO-Link (via C/Q = Pin 4), Interface type: IrDA (infrared interface), Output type: 2 push-pull (4 in 1) outputs, short-circuit protected, reverse polarity protected, UL approval: cULus Listed, Class 2 Power Sourcefa
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometerpa
Not available for purchase: 2-channel isolated barrier, 24 V DC supply (bus powered), Thermocouple, RTD or potentiometer input, Usable as signal splitter (1 input and 2 outputs), Linearized output 4 mA ... 20 mA, sink/source or 1 V ... 5 V, Sensor breakage detection, Configurable by PACTware, Line fault detection (LFD), Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 18 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20.4 ... 30 V DC bus powered via Termination Boardpa
Not available for purchase: 1-channel signal conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, voltage or current input, 2 relay contact outputs, Programmable high/low alarm, Configurable by PACTware, Sensor breakage detection, Housing width: 20 mm, Number of channels: 1-channel, Trip relay, Programmable high/low alarm, Rated voltage: 19 ... 35 V DC, Field device: resistance thermometer, Field device [2]: Thermocouple, Signal: 0/2 ... 10 V, Signal [2]: 0/4 ... 20 mA, Type: 2 x relay (change-over contact)pa
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, voltage or current input, 2 relay contact outputs, Programmable high/low alarm, Configurable by PACTware, Sensor breakage detection, Housing width: 20 mm, Number of channels: 1-channel, Trip relay, Programmable high/low alarm, Rated voltage: 19 ... 35 V DC, Field device: resistance thermometer, Field device [2]: Thermocouple, Signal: 0/2 ... 10 V, Signal [2]: 0/4 ... 20 mA, Type: 2 x relay (change-over contact)pa
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (Power Rail), Strain gauge input (full or half bridge), Output 0 mA ... ± 20 mA or 0 V ... ± 10 V, 2 relay contact outputs, Programmable high/low alarm, Configurable by PACTware or keypad, RS-485 interface, Low response time, Line fault detection (LFD), Housing width: 40 mm, Number of channels: 1-channel, Trip relay, Rated voltage: 20 ... 35 V DC, Field device: strain gauge bridge, Type: 2 x relay (change-over contact), Signal: 1 x -20 ... 20 mApa
Not available for purchase: 1-channel signal conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Field device: resistance thermometer, Field device [2]: Thermocouple, Field device [3]: potentiometer, Line fault detectionpa
Not available for purchase: 2-channel isolated barrier, 24 V DC supply, Thermocouple or RTD input, Current output 0/4 mA ... 20 mA, Configurable by PACTwarepa
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (bus powered), Thermocouple, RTD or potentiometer input, Linearized output 4 mA ... 20 mA, sink/source or 1 V ... 5 V, Sensor breakage detection, Configurable by PACTware, Line fault detection (LFD), Housing width: 18 mm, Number of channels: 1-channel, Rated voltage: 20.4 ... 30 V via Termination Boardpa
Learn more about the advantages of industrial radar sensors from Pepperl+Fuchs ... communication and a radar sensor DTM are available here. Various objects measured in the detection range can be visualized using a reflection analysis integrated in PACTware. Diagnostics are possible via the CANopen interface so that the radar sensors can also ...
See Overview: Pepperl+Fuchs diffuse mode and retroreflective mode ultrasonic sensors place the transmitter and receiver in the same housing ... commissioning ULTRA 3000, SONPROG, ULTRA-PROG-IR, and PACTware PC configuration tools — for optimal adaptation of sensors to their application Adjustable sound beam width — for optimal adaptation of the sensor characteristics to the relevant application ...
Pepperl+Fuchs' F77 ultrasonic sensor combines many functionalities in an ultra-compact housing design ... : compact, space-saving housing design with thru-hole and surface-mount versions Convenient commissioning: intuitive programming via push button or PACTware software Parameterization and control: communication to the sensor level with IO-Link ...
Reliable storage and conveying technology is essential for an efficient and smooth flow of materials in logistics centers, warehouses, and airports Read, how the R2000 Detection 2-D LiDAR sensor det ... field begins right below the pallet base, allowing it to detect even the smallest objects reliably. And setup is simple . With user-friendly PACTware software , the four user-configurable detection fields can be set in a matter of minutes. R2000 ...
Download PDF brochures and flyers on the latest Pepperl+Fuchs innovations shown at LogiMAT in Stuttgart, Germany ... offer information to you about the following topics: Pulse Ranging Technology Sophisticated Design for Maximum Efficiency The portfolio of LiDAR sensors from Pepperl+Fuchs PACTware R1000 Distance Sensor with Pulse Ranging Technology Download Now ...
Pepperl+Fuchs investigates all reports of security vulnerabilities affecting Pepperl+Fuchs products and services Contact us in case of any conspicuity ... WIBU SYSTEMS CodeMeter components 2020-05-29: Pepperl+Fuchs: PACTware–Recoverable Passwords and Unverified Password Change 2020-03-31: Pepperl+Fuchs: Kr00k Vulnerabilities in Broadcom Wi-Fi Chipsets 2019 2019-11-06: Pepperl+Fuchs: Security Advisory ...
This glossary gives you an overview of the most important terms and their meanings used in connection with IO-Link ... and provides a manufacturer-independent basis to access all communication and application features of a device for system-wide configuration and diagnostics. Example of an FDT: PACTware™. IO Device Description XML-based, static functional description ...
Industrial FMCW radar sensors from Pepperl+Fuchs feature a high-read range and are ideally suited for integration into mobile machines ... -relevant applications in conjunction with a fail-safe PLC, achieving a safety level of PL c Cat. 2 with just one sensor. The parameterization of the radar sensors is also donve conveniently via the well-known configuration tool PACTware . Here, both a COM ...
Download PDF brochures and flyers on the latest Pepperl+Fuchs innovations shown at the SPS in Nurember, Germany ... the following topics: Pulse Ranging Technology Sophisticated Design for Maximum Efficiency The portfolio of LiDAR sensors from Pepperl+Fuchs PACTware VisuNet FLX—the New Modular HMI Platform for Use up to Zone 2/22 and Div. 2 Download Now Perfect Match ...
UC18GS series ultrasonic sensors reliably detect the container level of liquids and granules, regardless of their color and other optical properties Learn more about the UC18GS ultrasonic sensor seri ... determines an average value and thus indicates the actual level - instead of a potentially distorted punctual value. Disturbance variables such as support struts or other objects reaching into the measuring field are suppressed by software (PACTware ...
11-20/26Items Per Page:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.