Serviceline Industrial Sensors
Serviceline Explosion Protection

Base for read/write station U-P6-B6

U-P6-B6
  • PROFIBUS DP acc. to EN 50170
  • 2 PG screw fittings for IN and OUT supply
    2 EMV PG screw fittings for BUS IN and OUT
  • Complete read/write functionality via the PROFIBUS DP
  • Transmission of up to 7 double words, 32 bit each, in one cycle
  • Connectable bus termination
  • Field device with degree of protection IP67

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH, also apply to Pepperl+Fuchs AG.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  U-P6-B6

Product Description
Base for PROFIBUS DP
Indicators/operating means
DIP switchSetting the station address
bus connection
ON = active  OFF = non-active
Electrical specifications
Rated operating voltage20 ... 30 V DC , ripple 10 %SS , PELV
Power consumptionmax. 5 W with read/write head IPT*-FP
Galvanic isolation
Operating voltage/interfacefunctional insulation acc. to DIN EN 50178, rated insulation voltage 50 Veff
Interface
Physical RS-485
ProtocolPROFIBUS DP acc. to EN 50170
Transfer rate9.6; 19.2; 93.75; 187.5; 500; 1500 kBit/s
3; 6; 12 Mbit/s self-synchronizing
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Degree of protectionIP67 according to EN 60529 with IPT*-FP
Connectionscrew terminals
Interface cable2 x 0.64 mm2, double screened, acc. to PROFIBUS standard EN 50170
Supplyup to 3 x 1.5 mm2
Material
Housingaluminum, black anodized

Documents: U-P6-B6

ManualsLanguageFile TypeFile Size
Manual IPTx-FP with U-P6x-B6xENGPDF2364 KB
Handbuch IPTx-FP mit U-P6x-B6xGERPDF2471 KB
Manual IPTx-FP with U-P6x-B6xRUSPDF2907 KB
Instruction leaflets
Instruction leaflet / Beipackzettel ALLPDF170 KB

Approvals+Certificates: U-P6-B6

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of conformity / EU-KonformitätserklärungDOC-3497PDF162 KB
Certificates
Russia TUV GOST-R101-KC/542PDF90 KB

Software: U-P6-B6

DriversRelease InfoFile TypeFile Size
GSD file U-P6*-B6* / GSD-Datei U-P6*-B6*08/2005ZIP2 KB

Associated Products: U-P6-B6

Matching system components
LF R/W system, fully assembled as configuration and test stationfa

Function: U-P6-B6

The base is used in combination with an upper part, the IPT*-FP read/write station.

The device is operated as a slave on the PROFIBUS DP. The device makes available the complete read/write functionality. Up to 32 bytes are transmitted per cycle. Of these, up to 7 double words, each with 32 bits, are available to the user.

The address is set and the terminating resistor for the bus is connected via DIP switches.

While the bus termination is switched on, the subsequent subscribers which are connected to the terminals (P, N out) are disconnected from the bus.